A Cu/Hg-plated screen-printed electrode (CMSPE) was developed for trace Pb(ll) determination by square-wave anodic stripping voltammetry. The intermetallic property of lead with copper in mercury was utilized to increase the sensitivity of Pb(II) detection. The calculated transfer coefficient value for the Pb(II)/Pb redox process on the CMSPE is similar to 0.5 representing the ideality of the system for Pb(II) detection. Systematic investigations were made to optimize the Cu-Hg plating condition on SPE towards the Pb(II) signals in terms of Cu/Hg ratio, plating potential, and plating time. The optimum conditions for electrochemical and square-wave parameters were also evaluated. The calibration curve was linear in the range of 0-100 ppb Pb(II) with a detection limit of 0.81 ppb (S/N = 3) for 60 s preconcentration time. The analytical utility of the CMPSE was demonstrated by applying to various water samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [41] Macroporous Bismuth Film Screen-Printed Carbon Electrode for Simultaneous Determination of Ni(II) and Co(II)
    Dal Borgo, Sebastiano
    Sopha, Hanna
    Smarzewska, Sylwia
    Hocevar, Samo B.
    Svancara, Ivan
    Metelka, Radovan
    ELECTROANALYSIS, 2015, 27 (01) : 209 - 216
  • [42] Simulating the phase II metabolism of raloxifene on a screen-printed electrode
    Vasiliadou, Rafaela
    Welham, Kevin J.
    CANADIAN JOURNAL OF CHEMISTRY, 2017, 95 (10) : 1085 - 1089
  • [43] Electrochemical determination of tramadol using modified screen-printed electrode
    Mohammadi, Sayed Zia
    Jafari, Maedeh
    Jahani, Peyman Mohammadzadeh
    Ahmadi, Sayed Ali
    Mashayekh, Raana
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, 12 (01): : 127 - 135
  • [44] Electrochemically Activated Screen-Printed Carbon Electrode for Determination of Ibuprofen
    Tyszczuk-Rotko, Katarzyna
    Kozak, Jedrzej
    Wezinska, Anna
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [45] ELECTROCHEMICAL REGENERATION OF THE SURFACE OF A MERCURY-PLATED GRAPHITE ELECTRODE FOR INVERSION VOLTAMMETRY
    TSYUPKO, TG
    TURYAN, YI
    TEMERDASHEV, ZA
    TURYAN, IY
    MALUKA, LM
    JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 48 (12) : 1371 - 1374
  • [46] Determination of trace lead in purified water with screen-printed electrodes
    Zhang, J
    Yuan, ZB
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (01) : 47 - 51
  • [47] Photoelectrocatalytic oxidation of o-phenols on copper-plated screen-printed electrodes
    Zen, JM
    Chung, HH
    Yang, HH
    Chiu, MH
    Sue, JW
    ANALYTICAL CHEMISTRY, 2003, 75 (24) : 7020 - 7025
  • [48] Selective detection of o-diphenols on copper-plated screen-printed electrodes
    Zen, JM
    Chung, HH
    Kumar, AS
    ANALYTICAL CHEMISTRY, 2002, 74 (05) : 1202 - +
  • [49] Photoelectrochernical oxygen copper-plated screen-printed sensor using carbon electrodes
    Zen, JM
    Song, YS
    Chung, HH
    Hsu, CT
    Kumar, AS
    ANALYTICAL CHEMISTRY, 2002, 74 (23) : 6126 - 6130
  • [50] Determination of Copper(II) Through Anodic Stripping Voltammetry in Tartrate Buffer Using an Antimony Film Screen-printed Carbon Electrode
    Bobrowski, Andrzej
    Maczuga, Mariola
    Krolicka, Agnieszka
    Konstanteli, Evangelia
    Sakellaropoulou, Chrysavgi
    Economou, Anastasios
    ANALYTICAL LETTERS, 2017, 50 (18) : 2920 - 2936