Validated Stability-Indicating High-Performance Liquid Chromatography and Thin-Layer Chromatography Methods for the Determination of Zopiclone in Pharmaceutical Formulation

被引:5
|
作者
Razeq, Sawsan A. Abdel [1 ]
Soliman, Suzan M. [2 ]
Mohamed, Amal S. [2 ]
机构
[1] Al Azhar Univ, Fac Pharm, Analyt Chem Dept, Cairo, Egypt
[2] NODCAR, Giza, Egypt
关键词
Zopiclone; Stability-indicating assay; High-performance liquid chromatography; Thin-layer chromatography-densitometry; IR and mass spectrometry; Degradation pathway; DIODE-ARRAY DETECTION; QUANTITATIVE-DETERMINATION; N-DESMETHYLZOPICLONE; RP-HPLC; GC-MS; 2-AMINO-5-CHLOROPYRIDINE; TABLETS; URINE; IMOVANE(R); SPECIMENS;
D O I
10.1556/1006.2018.31.4.5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel, sensitive, and selective stability-indicating chromatographic methods were described for the analysis of zopiclone (ZOP) in the presence of its degradation products, namely, 7-oxo-6,7-dihydro-5H-pyrrolo[3,4-b]pyrazin-5-yl-4-methylpiperazine-1-carboxylate (hydrolytic DEG) and 5H-pyrrolo[3,4-b]pyrazine-5,7(6H)-dione (oxidative DEG), in drug substance and product. The first method was an isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) using Inertsil ODS3 (250 x 4 mm, 5 mu m) column. Upon using HPLC, the run time could be reduced, and actually, the solvents consumption decreased. Quantification was achieved by detection wavelength at 237 nm, based on peak area. Chromatographic separation was performed over the range of 1-10 mu g mL(-1) with limits of detection (LOD) and quantification (LOQ) of 0.18 and 0.55 mu g mL(-1) and a mean recovery of 99.98 +/- 0.55. The analysis was achieved at 30 degrees C using a mixture of acetonitrile and water (50:50 v/v) as the mobile phase. The second method was thin-layer chromatography (TLC) applied for the separation and analysis of zopiclone in the presence of its alkaline, acidic, and oxidative degradation products. Chromatography was performed on silica gel 60 F-254 plates with ethyl acetate. methanol. ammonia 33% (17:2:1 v/v) as the mobile phase. Successful resolution was observed with significant difference in the R-F values, followed by densitometric measurement at 303 nm. Evaluation was carried out over the range of 0.1-2 mu g per spot with a mean recovery of 100.52% +/- 0.24. The developed methods were successfully applied to the analysis of ZOP in bulk powder, laboratory-prepared mixtures containing different percentages of its degradation products, and pharmaceutical dosage form. The degradation products were separated by HPLC as well as identified by TLC, infrared (IR), and mass spectrometry (MS) to confirm its structures and elucidate degradation pathway. The developed methods were validated as per the International Conference on Harmonization (ICH) guidelines. The results obtained by the proposed methods were statistically compared with the reported methods revealing high accuracy and good precision.
引用
收藏
页码:297 / 308
页数:12
相关论文
共 50 条
  • [21] Stability-indicating high performance thin layer chromatography determination of Paroxetine hydrochloride in bulk drug and pharmaceutical formulations
    Venkatachalam, A.
    Chatterjee, Vidya S.
    ANALYTICA CHIMICA ACTA, 2007, 598 (02) : 312 - 317
  • [22] Simultaneous Determination of Atorvastatin Calcium and Olmesartan Medoxomil in a Pharmaceutical Formulation by Reversed Phase High-Performance Liquid Chromatography, High-Performance Thin-Layer Chromatography, and UV Spectrophotometric Methods
    Soni, Hiral
    Kothari, Charmy
    Khatri, Deepak
    Mehta, Priti
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (03) : 791 - 797
  • [23] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC STABILITY-INDICATING DETERMINATION OF ZOPICLONE IN TABLETS
    BOUNINE, JP
    TARDIF, B
    BELTRAN, P
    MAZZO, DJ
    JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) : 87 - 93
  • [24] Development of a Validated Stability-Indicating High-Performance Thin-Layer Chromatographic Method for the Quantification of Levetiracetam
    Bhattacharya, Plaban
    Ghosh, Manasi
    Chatterjee, Abhijeet
    Bangal, Sudipta
    Saha, Achintya
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2014, 27 (02) : 132 - 139
  • [25] Development of a Validated Stability-Indicating High-Performance Thin-Layer Chromatographic Method for the Quantification of Levetiracetam
    Plaban Bhattacharya
    Manasi Ghosh
    Abhijeet Chatterjee
    Sudipta Bangal
    Achintya Saha
    JPC – Journal of Planar Chromatography – Modern TLC, 2014, 27 : 132 - 139
  • [26] Stability-Indicating High-Performance Thin-Layer Chromatographic Determination of Zidovudine as the Bulk drug and in Pharmaceutical Dosage Forms
    Neeraj Kaul
    Himani Agrawal
    Anant Raghunath Paradkar
    Kakasaheb Ramoo Mahadik
    JPC – Journal of Planar Chromatography – Modern TLC, 2004, 17 : 264 - 274
  • [27] Stability-indicating high-performance thin-layer chromatographic determination of zidovudine as the bulk drug and in pharmaceutical dosage forms
    Kaul, N
    Agrawal, H
    Paradkar, AR
    Mahadik, KR
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2004, 17 (04) : 264 - 274
  • [28] Validated stability-indicating densitometric thin-layer chromatography: Application to stress degradation studies of minocycline
    Jain, Nilu
    Jain, Gaurav Kumar
    Ahmad, Farhan Jalees
    Khar, Roop Krishen
    ANALYTICA CHIMICA ACTA, 2007, 599 (02) : 302 - 309
  • [29] Stability-indicating High-performance Liquid Chromatography Method for Simultaneous Determination of Aminophylline and Chlorpheniramine Maleate in Pharmaceutical Formulations
    Ali, A.
    Ahmed, M.
    Mahmud, T.
    Qadir, M. A.
    Nadeem, K.
    Saleem, A.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 77 (05) : 515 - 521
  • [30] Stability-indicating high-performance thin-layer chromatography method for the simultaneous estimation of emtricitabine and tenofovir alafenamide fumarate
    Kashid, Arun M.
    Kadam, Rohini R.
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2021, 34 (03) : 253 - 261