Amperometric hydrogen peroxide biosensor based on horseradish peroxidase-labeled nano-Au colloids immobilized on poly(2,6-pyridinedicarboxylic acid) layer by cysteamine

被引:10
|
作者
Li, CX [1 ]
Deng, KQ
Shen, GL
Yu, RQ
机构
[1] Hunan Univ Sci & Technol, Coll Chem & Chem Engn, Xiangtan 411201, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Peoples R China
关键词
D O I
10.2116/analsci.20.1277
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive hydrogen peroxidase (H2O2) amperometric sensor based on horseradish peroxidase (HRP)-labeled nano-Au colloids has been proposed. Nano-Au colloids were immobilized by the thiol group of cysteamine, which was associated with the carboxyl groups of poly(2,6-pyridinedicarboxylic acid) (PPDA). With the aid of the hydroquinone, the sensor displayed excellent electrocatalytical response to the reduction of H2O2, Compared with the non-Au-colloid modified electrode, i.e., PPDA/HRP, the Au-colloid modified electrode exhibited better performance characteristics, including stability, reproducibility, sensitivity and accuracy. The biosensor shows a linear response to H2O2 in the range of 3.0 x 10(-7) - 2 x 10(-3) M. The detection limit was 1.0 X 10(-7) M.
引用
收藏
页码:1277 / 1281
页数:5
相关论文
共 28 条
  • [1] Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase-labeled Nano-Au Colloids Immobilized on Poly(2,6-pyridinedicarboxylic acid) Layer by Cysteamine
    Chun-Xiang Li
    Ke-Qing Deng
    Guo-Li Shen
    Ru-Qin Yu
    Analytical Sciences, 2004, 20 : 1277 - 1281
  • [2] Hydrogen peroxide sensor based on nano-Au colloids immobilized on 2,6-pyridinedicarboxylic acid polymer
    Li, CX
    Yang, MH
    Shen, GL
    Yu, RQ
    ACTA CHIMICA SINICA, 2004, 62 (17) : 1663 - 1667
  • [3] Hydrogen peroxide sensor based on horseradish peroxidase-labeled Au colloids immobilized on gold electrode surface by cysteamine monolayer
    Xiao, Y
    Ju, HX
    Chen, HY
    ANALYTICA CHIMICA ACTA, 1999, 391 (01) : 73 - 82
  • [4] A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode
    Shurui Cao
    Ruo Yuan
    Yaqin Chai
    Lingyan Zhang
    Xuelian Li
    Fengxian Gao
    Bioprocess and Biosystems Engineering, 2007, 30 : 71 - 78
  • [5] A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode
    Cao, Shurui
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Lingyan
    Li, Xuelian
    Gao, Fengxian
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2007, 30 (02) : 71 - 78
  • [6] An amperometric hydrogen peroxide biosensor based on immobilizing horseradish peroxidase to a nano-Au monolayer supported by sol-gel derived carbon ceramic electrode
    Lei, CX
    Hu, SQ
    Gao, N
    Shen, GL
    Yu, RQ
    BIOELECTROCHEMISTRY, 2004, 65 (01) : 33 - 39
  • [7] Study on a hydrogen peroxide sensor based on horseradish peroxidase/nano-Au/horseradish peroxidase/multi-walled carbon nanotubes
    Zhang Ling-Yan
    Yuan Ruo
    Chai Ya-Qin
    Cao Shu-Rui
    Li Xue-Lian
    Wang Na
    ACTA CHIMICA SINICA, 2006, 64 (16) : 1711 - 1715
  • [8] Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on nano-Au/Thi/poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Gao, Fengxian
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    Cao, Shurui
    Tang, Mingyu
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2007, 70 (03): : 407 - 413
  • [9] Development of amperometric hydrogen peroxide sensor based on horseradish peroxidase-immobilized poly(Thiophene-co-EpoxyThiophene)
    Kim, Hwa-Jung
    Piao, Ming-Hua
    Choi, Seong-Ho
    Shin, Chang-Ho
    Lee, Young-Taeg
    SENSORS, 2008, 8 (07): : 4110 - 4118
  • [10] An H2O2 biosensor based on immobilization of horseradish peroxidase labeled nano-Au in silica sol-gel/alginate composite film
    Lei, CX
    Long, LP
    Can, ZL
    ANALYTICAL LETTERS, 2005, 38 (11) : 1721 - 1734