Experimental study on the performance of an epithermal neutron flux monitor for BNCT

被引:14
|
作者
Guan, Xingcai [1 ]
Manabe, Masanobu [2 ]
Tamaki, Shingo [2 ]
Liu, Shuangtong [1 ]
Sato, Fuminobu [2 ]
Murata, Isao [2 ]
Wang, Tieshan [1 ]
机构
[1] Lanzhou Univ, Sch Nucl Sci & Technol, Tianshui South Rd 222, Lanzhou 730000, Gansu, Peoples R China
[2] Osaka Univ, Div Sustainable Energy & Environm Engn, Grad Sch Engn, Yamada Oka 2-1, Suita, Osaka 5650871, Japan
关键词
Epithermal neutron; Neutron flux monitor; BNCT neutron source; OKTAVIAN;
D O I
10.1016/j.apradiso.2016.04.003
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The performance of an epithermal neutron (0.5 eV < E-n < 10 keV) flux monitor designed for boron neutron capture therapy (BNCT) was experimentally studied by using a prototype monitor in an appropriate neutron field at the intense deuterium-tritium neutron source facility OKTAVIAN of Osaka University, Japan. It was convinced from the experimental results that the developed monitor worked well and the epithermal neutron fluxes in BNCT neutron sources can be measured within 5% by the monitor. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [41] The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields
    Schmitz, T.
    Bassler, N.
    Blaickner, M.
    Ziegner, M.
    Hsiao, M. C.
    Liu, Y. H.
    Koivunoro, H.
    Auterinen, I.
    Seren, T.
    Kotiluoto, P.
    Palmans, H.
    Sharpe, P.
    Langguth, P.
    Hampel, G.
    MEDICAL PHYSICS, 2015, 42 (01) : 400 - 411
  • [42] Design of an epithermal neutron beam for BNCT in thermal column of Tehran research reactor
    Kasesaz, Yaser
    Khalafi, Hossein
    Rahmani, Faezeh
    ANNALS OF NUCLEAR ENERGY, 2014, 68 : 234 - 238
  • [43] The neutron flux monitors from 20 keV to 1 MeV for BNCT: performance study using accelerator-based neutron sources
    Guan, X. C.
    Gong, Y.
    Murata, I.
    Wang, T. S.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [44] Dosimetry chain for the dogs irradiated in the epithermal neutron beam at the Finnish BNCT facility
    Savolainen, S
    Auterinen, I
    Aschan, C
    Hiismäki, P
    Kortesniemi, M
    Kosunen, AK
    Kotiluoto, P
    Lampinen, J
    Seppälä, T
    Serén, T
    Tanner, V
    Toivonen, M
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1245 - 1250
  • [45] Conceptual design of epithermal neutron beam for BNCT in the TRIGA reactor thermalizing column
    Maucec, M
    Glumac, B
    PROCEEDINGS OF THE WORKSHOP "MONTE CARLO METHODS AND MODELS FOR APPLICATIONS IN ENERGY AND TECHNOLOGY", 1999, 6266 : 281 - +
  • [46] Application of an ultra-miniature thermal neutron monitor for BNCT irradiation field study
    Ishikawa, Masayori
    Kumada, Hiroaki
    Yamamoto, Kazuyoshi
    Kaneko, Junichi H.
    Takahashi, Hiroyuki
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2917 - 2919
  • [47] Clinical significance of in-phantom evaluation parameters for epithermal neutron beams in BNCT
    Gupta, N
    Gahbauer, R
    Blue, TE
    Woollard, J
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A264 - A270
  • [48] Spectrum measurements and calculations in the epithermal neutron beam at the FiR 1 BNCT facility
    Serén, T
    Auterinen, L
    Seppälä, T
    Kotiluoto, P
    15TH EUROPEAN TRIGA CONFERENCE, 1999, 197 : 167 - 179
  • [49] Scintillation Detector for Neutron Flux Monitoring at the BNCT Facility
    Leonov, V. V.
    Porosev, V. V.
    Savinov, G. A.
    Taskaev, S. Yu.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2024, 67 (SUPPL2) : S311 - S315
  • [50] A novel digital neutron flux monitor for international thermonuclear experimental reactor
    周翔
    刘子豪
    陈超
    朱仁杰
    赵丽
    魏凌峰
    阴泽杰
    Plasma Science and Technology, 2018, 20 (06) : 198 - 203