Mono- versus polyaxial locking plates in distal femur fractures - a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate

被引:20
|
作者
El-Zayat, Bilal Farouk [1 ]
Efe, Turgay [1 ]
Ruchholtz, Steffen [2 ]
Khatib, Salim [2 ]
Timmesfeld, Nina [3 ]
Krueger, Antonio [2 ]
Zettl, Ralph [4 ]
机构
[1] Univ Hosp Marburg, Dept Orthopaed & Rheumatol, D-35043 Marburg, Germany
[2] Univ Hosp Marburg, Dept Trauma Hand & Reconstruct Surg, D-35043 Marburg, Germany
[3] Univ Marburg, Inst Med Biometry & Epidemiol, D-35037 Marburg, Germany
[4] Kantonsspital Frauenfeld, Dept Orthopaed Surg, CH-8501 Frauenfeld, Switzerland
关键词
Monoaxial and polyaxial locking plates; Biomechanical study; Distal femur fracture; NCB; PERILOC; INVASIVE STABILIZATION SYSTEM; PERIPROSTHETIC FEMORAL FRACTURES; ANGLED BLADE PLATE; INTERNAL-FIXATION; INTRAMEDULLARY NAIL; VANCOUVER TYPE-B1; COMPRESSION PLATE; TOTAL HIP; LISS; BONE;
D O I
10.1186/1471-2474-15-369
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The aim of this cadaveric study was to compare a polyaxial (NCB (R), Zimmer) to a fixed-angle monoaxial locking plate (PERILOC (R), Smith & Nephew) in comminuted fractures of the distal femur regarding stability of the construct. Up to date there is no published biomechanical data concerning polyaxial plating in cadaveric distal femurs. Methods: Fourteen formalin fixed femora were scanned by dual-energy x-ray absorptiometry. As fracture model an unstable supracondylar comminuted fracture was simulated. Fractures were pairwise randomly fixed either with a mono- (group A) or a polyaxial (group B) distal femur plate. The samples were tested in a servohydraulic mechanical testing system starting with an axial loading of 200 N following an increase of 200 N in every step with 500 cycles in every sequence up to a maximum of 2 000 N. The end points were implant failure or relevant loss of reduction. Data records included for each specimen time, number of cycles, axial load and axial displacement. Statistical analysis was performed using the exact Wilcoxon signed rank test. Results: The mean donor age at the time of death was 75 years. The bone mass density (BMD) of the femurs in both groups was comparable and showed no statistically significant differences. Five bones failed before reaching the maximum applied force of 2000 N. Distribution curves of all samples in both groups, showing the plastic deformation in relation to the axial force, showed no statistically significant differences. Conclusions: Operative stabilization of distal femur fractures can be successfully and equally well achieved using either a monoaxial or a polyaxial locking plate. Polyaxial screw fixation may have advantages if intramedullary implants are present.
引用
收藏
页数:7
相关论文
共 27 条
  • [21] A comparison of outcomes of locking versus non-locking plate fixation for the distal fibula fractures: a systematic review and meta-analysis
    Dhillon, Mandeep Singh
    Rajnish, Rajesh Kumar
    Kumar, Prasoon
    Sharma, Siddhartha
    Singh, Gagan Preet
    Srivastava, Amit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01): : 75 - 89
  • [22] A comparison of outcomes of locking versus non-locking plate fixation for the distal fibula fractures: a systematic review and meta-analysis
    Mandeep Singh Dhillon
    Rajesh Kumar Rajnish
    Prasoon Kumar
    Siddhartha Sharma
    Gagan Preet Singh
    Amit Srivastava
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 75 - 89
  • [23] Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model
    Rudig, Lothar
    Mehling, Isabella
    Klitscher, Daniela
    Mehler, Dorothea
    Prommersberger, Karl-Josef
    Rommens, Pol M.
    Mueller, Lars Peter
    BIOMEDIZINISCHE TECHNIK, 2009, 54 (03): : 150 - 158
  • [24] Comparison of three surgical methods in the treatment of intraarticular comminuted distal radius fractures: Volar locking plate, non-bridging external fixator, and bridging external fixator
    Talmac, Mehmet Ali
    Gorgel, Mehmet Akif
    Kanar, Muharrem
    Tok, Okan
    Ozdemir, Haci Mustafa
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2019, 30 (03): : 224 - 232
  • [25] Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression
    Marshall, Tyler
    Momaya, Amit
    Eberhardt, Alan
    Chaudhari, Nilesh
    Hunt, Thomas R., III
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10): : 2032 - 2038
  • [26] Comparison of outcomes of retrograde intramedullary nailing versus locking plate fixation in distal femur fractures: A Systematic Review and Meta-analysis of 936 patients in 16 studies
    Aggarwal, Sameer
    Rajnish, Rajesh Kumar
    Kumar, Prasoon
    Srivastava, Amit
    Rathor, Kuldeep
    Ul Haq, Rehan
    JOURNAL OF ORTHOPAEDICS, 2023, 36 : 36 - 48
  • [27] Letter Regarding "Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression"
    Spiegel, Adrian
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (07): : E225 - E225