Scatter correction for flat detector cone-beam CT based on simulated sphere models

被引:16
|
作者
Bertram, M. [1 ]
Hohmann, S. [1 ]
Wiegert, J. [1 ]
机构
[1] Philips Res Europe, Aachen, Germany
关键词
D O I
10.1118/1.2760399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Uncompensated scattered radiation is one of the major image quality deteriorating factors in flat detector cone‐beam CT. Purpose of this work is to develop a fast, practical, and accurate method for a posteriori correction of X‐ray scatter. Method and Materials: Scatter estimation and correction is carried out using a novel approach based on locally approximating the imaged object by water sphere models. In each projection, the scatter contribution of each ray from the source to the individual detector pixels is derived from a pre‐calculated database of pencil‐beam Monte‐Carlo simulations. The different sphere configurations have the advantage over related existing methods that they allow to accurately reproduce scatter contributions of individual rays regardless of the position of object penetration. Systematic evaluation was carried out by constructing an extensive database of Monte‐Carlo patient simulations, by performing scatter measurements of 15 phantoms on a bench‐top X‐ray system, and based on rotational C‐arm acquisitions from clinical interventional procedures. Results: The novel method was found to produce far superior results than related state‐of‐the‐art approaches. Based on simulated projections of 13 CT data sets of different body regions (head, thorax, abdomen, liver, pelvis), an average reduction of scatter‐caused inhomogeneities from 117 HU to 11 HU per‐voxel deviation from the ground truth was achieved. For individual data sets, the average level of the estimated scatter deviated from the respective optimum by only 5% as compared to a minimum of 14% for tested state‐of‐the‐art approaches. Experimental evaluation and application to clinical data confirmed robustness and efficient reduction of cupping and streak artifacts in reconstructed images. Conclusion: A practical software‐based method was developed allowing to accurately estimate scatter contributions in X‐ray projections. Utilization of this method efficiently reduces scatter‐caused artifacts, and thus substantially improves image quality in flat detector cone‐beam CT. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2342 / 2343
页数:2
相关论文
共 50 条
  • [11] Scatter correction for cone-beam CT in radiation therapy
    Zhu, Lei
    Xie, Yaoqin
    Wang, Jing
    Xing, Lei
    MEDICAL PHYSICS, 2009, 36 (06) : 2258 - 2268
  • [12] Noise Suppression in Scatter Correction for Cone-Beam CT
    Xing, L.
    Wang, J.
    Zhu, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [13] Image lag modeling and correction method for flat panel detector in cone-beam CT
    Huang Kui-Dong
    Zhang Ding-Hua
    Li Ming-Jun
    Zhang Hua
    ACTA PHYSICA SINICA, 2013, 62 (21)
  • [14] Scatter correction method for cone-beam CT based on interlacing-slit scan
    黄魁东
    张华
    史仪凯
    张亮
    徐哲
    Chinese Physics B, 2014, (09) : 519 - 525
  • [15] Scatter measurement and correction method for cone-beam CT based on single grating scan
    Huang, Kuidong
    Shi, Wenlong
    Wang, Xinyu
    Dong, Yin
    Chang, Taoqi
    Zhang, Hua
    Zhang, Dinghua
    OPTICAL ENGINEERING, 2017, 56 (06)
  • [16] Local filtration based scatter correction for cone-beam CT using primary modulation
    Zhu, Lei
    MEDICAL PHYSICS, 2016, 43 (11) : 6199 - 6209
  • [17] Scatter correction method for cone-beam CT based on interlacing-slit scan
    Huang Kui-Dong
    Zhang Hua
    Shi Yi-Kai
    Zhang Liang
    Xu Zhe
    CHINESE PHYSICS B, 2014, 23 (09)
  • [18] Scatter characterization in cone-beam CT systems with offset flat panel imagers
    Virshup, G.
    Suri, R.
    Star-Lack, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2288
  • [19] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [20] Model based scatter correction for cone-beam computed tomography
    Wiegert, J
    Bertram, M
    Rose, G
    Aach, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 271 - 282