Electrochemical Detection of Paracetamol Using Graphene Oxide -Modified Glassy Carbon Electrode

被引:0
|
作者
Zidan, Mohammed [1 ]
Zawawi, Ruzniza Mohd [2 ]
Erhayem, Mohamed [1 ]
Salhin, Abdussalam [3 ]
机构
[1] Univ Sebha, Dept Chem, Fac Sci, Sabha, Libya
[2] Univ Putra Malaysia, Dept Chem, Fac Sci, Upm 43400, Serdang, Malaysia
[3] Sirte Univ, Fac Sci, Dept Chem, Sirte, Libya
来源
关键词
graphene oxide (GO); Modified GC electrode; paracetamol; Cyclic Voltammetry (CV); ACETAMINOPHEN; OXIDATION; SENSOR;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A very sensitive electrochemical sensor has been developed by modification of glassy carbon electrode (GCE) with graphene oxide (GO). The electrochemical behavior of paracetamol was studied at GO/GCE using cyclic voltammetry (CV) and square-wave voltammetric techniques (SWV). A well defined oxidation peak was observed in 0.1 M KH2PO4 electrolyte solution by solid phase voltammetry. Under the CV techniques, it appears that the catalytic effect of the modification on graphene oxide GO/GCE shows higher current response as compared to bare GCE. Observed peak potential was shifted to less positive value by about 220 mV and current was significantly enhanced by about 2 folds. Square-wave voltammetry showed higher sensitive response than CV techniques, where current was significantly enhanced by more than 2 folds. Under the optimum conditions, the oxidation peak current of paracetamol varied linearly with concentration over a wide range of 5 x 10(-8) mol L-1 to 1 x10(-6) mol L-1 and the detection limit of this method was as low as 4.9 x 10(-8) M.
引用
收藏
页码:7605 / 7613
页数:9
相关论文
共 50 条
  • [31] The graphene/polypyrrole/chitosan-modified glassy carbon electrode for electrochemical nitrite detection
    Qi Xiao
    Mengmeng Feng
    Yi Liu
    Shuangyan Lu
    Yingzi He
    Shan Huang
    Ionics, 2018, 24 : 845 - 859
  • [32] Electrochemical detection of bisphenol A at graphene/melamine nanoparticle-modified glassy carbon electrode
    Rongyan Shen
    Weiming Zhang
    Yuan Yuan
    Guangyu He
    Haiqun Chen
    Journal of Applied Electrochemistry, 2015, 45 : 343 - 352
  • [33] The graphene/polypyrrole/chitosan-modified glassy carbon electrode for electrochemical nitrite detection
    Xiao, Qi
    Feng, Mengmeng
    Liu, Yi
    Lu, Shuangyan
    He, Yingzi
    Huang, Shan
    IONICS, 2018, 24 (03) : 845 - 859
  • [34] Electrochemical detection of bisphenol A at graphene/melamine nanoparticle-modified glassy carbon electrode
    Shen, Rongyan
    Zhang, Weiming
    Yuan, Yuan
    He, Guangyu
    Chen, Haiqun
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2015, 45 (04) : 343 - 352
  • [35] Enhancing Dopamine Detection Using Glassy Carbon Electrode Modified with Graphene Oxide, Nickel and Gold Nanoparticles
    Hassine, Chedia Ben Ali
    Kahri, Hamza
    Barhoumi, Houcine
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [36] Chemically modified glassy carbon electrode for electrochemical sensing paracetamol in acidic solution
    Guocheng Yang
    Lu Wang
    Jianbo Jia
    Defeng Zhou
    Dongfeng Li
    Journal of Solid State Electrochemistry, 2012, 16 : 2967 - 2977
  • [37] Chemically modified glassy carbon electrode for electrochemical sensing paracetamol in acidic solution
    Yang, Guocheng
    Wang, Lu
    Jia, Jianbo
    Zhou, Defeng
    Li, Dongfeng
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (09) : 2967 - 2977
  • [38] Electrochemical determination of imidacloprid using poly(carbazole)/chemically reduced graphene oxide modified glassy carbon electrode
    Lei, Wu
    Wu, Qiuju
    Si, Weimeng
    Gu, Zhenyan
    Zhang, Yuehua
    Deng, Jiping
    Hao, Qingli
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 102 - 109
  • [39] Electrochemical determination of dopamine using a glassy carbon electrode modified with TiN-reduced graphene oxide nanocomposite
    Haldorai, Yuvaraj
    Vilian, A. T. Ezhil
    Rethinasabapathy, Muruganantham
    Huh, Yun Suk
    Han, Young-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 61 - 69
  • [40] Electrochemical behavior and voltammetric determination of paracetamol on Nafion/TiO2-graphene modified glassy carbon electrode
    Fan, Yang
    Liu, Jin-Hang
    Lu, Hai-Ting
    Zhang, Qin
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 85 (02) : 289 - 292