Low-cost, smartphone-based frequency doubling technology visual field testing using a head-mounted display

被引:28
|
作者
Alawa, Karam AlRahman [1 ]
Nolan, Ryan P. [1 ]
Han, Elaine [1 ]
Arboleda, Alejandro [2 ]
Durkee, Heather [2 ]
Sayed, Mohamed S. [1 ]
Aguilar, Mariela C. [2 ]
Lee, Richard K. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Ophthalmol, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Univ Miami, Miller Sch Med, Ophthalm Biophys Ctr, Bascom Palmer Eye Inst, Miami, FL 33136 USA
关键词
Glaucoma; Field of vision; Telemedicine;
D O I
10.1136/bjophthalmol-2019-314031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Current visual field screening machines are bulky and expensive, limiting their accessibility, affordability and use. We report the design and evaluation of a novel, portable, cost-effective system for glaucoma screening using smartphone-based visual field screening using frequency doubling technology (FDT) and a head-mounted display. Methods Nineteen eyes of 10 subjects with new-onset or chronic primary open angle glaucoma were tested and compared with the Humphrey Zeiss FDT and the newly developed Mobile Virtual Perimetry (MVP) FDT with the C-20 testing pattern. Mann-Whitney, Bland-Altman and linear regression analyses were performed to assess statistical difference, agreement and correlation, respectively, between the two devices. Results The average age of the participants was 58 +/- 15 years. No statistically significant difference was found between the MVP FDT and the Humphrey Zeiss FDT (p>0.05). Bland-Altman and linear regression analyses demonstrated good agreement and correlation between the two devices. Conclusion The MVP FDT is a low-cost, portable visual field screening device that produces comparable results to the Humphrey Zeiss FDT and may be used as an easily accessible screening tool for glaucoma.
引用
收藏
页码:440 / 444
页数:5
相关论文
共 50 条
  • [31] Concept for Using Eye Tracking in a Head-Mounted Display to Adapt Rendering to the User's Current Visual Field
    Pohl, Daniel
    Zhang, Xucong
    Bulling, Andreas
    Grau, Oliver
    22ND ACM CONFERENCE ON VIRTUAL REALITY SOFTWARE AND TECHNOLOGY (VRST 2016), 2016, : 323 - 324
  • [32] Smartphone-Based Hyperspectral Imaging - Low-Cost Application for Telemedicine
    Vogt J.
    Martin S.
    Franke J.
    Studies in Health Technology and Informatics, 2023, 301 : 69 - 70
  • [33] A Low-cost, Low-latency Approach to Dynamic Immersion in Occlusive Head-Mounted Displays
    Lindeman, Robert W.
    2016 IEEE VIRTUAL REALITY CONFERENCE (VR), 2016, : 221 - 222
  • [34] Visual Field Testing in a Telehealth Setting: Remote Perimetry Using a Head-Mounted Device in Normal Eyes
    McLaughlin, Danielle
    Munshi, Hounsh
    Savatovsky, Eleonore
    Vanner, Elizabeth
    Chang, Ta Chen
    Grajewski, Alana L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [35] Using Visual Intelligence to Automate Maintenance Task Guidance and Monitoring on a Head-mounted Display
    Ng, Lai Xing
    Ng, Jamie
    Tang, Keith T. W.
    Li, Liyuan
    Rice, Mark
    Wan, Marcus
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ROBOTICS AND ARTIFICIAL INTELLIGENCE, ICRAI 2019, 2019, : 70 - 75
  • [36] A Stray Light Detection Model for VR Head-Mounted Display Based on Visual Perception
    Li, Hung-Chung
    Tsai, Meng-Che
    Lee, Tsung-Xian
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [37] A Low-Cost Test Environment for Usability Studies of Head-Mounted Virtual Reality Systems
    Seffah, Ahmed
    Benn, Jonathan
    Mammar, Halima Habieb
    JOURNAL OF USABILITY STUDIES, 2008, 3 (02) : 60 - 73
  • [38] Evaluation of photography using head-mounted display technology (ICAPS) for district Trachoma surveys
    Naufal, Fahd
    Brady, Christopher J.
    Wolle, Meraf A.
    Saheb Kashaf, Michael
    Mkocha, Harran
    Bradley, Christopher
    Kabona, George
    Ngondi, Jeremiah
    Massof, Robert W.
    West, Sheila K.
    PLOS NEGLECTED TROPICAL DISEASES, 2021, 15 (11):
  • [39] The learning effect in visual field testing of healthy subjects using frequency doubling technology
    Horani, A
    Frenkel, S
    Yahalom, C
    Farber, MD
    Ticho, U
    Blumenthal, EZ
    JOURNAL OF GLAUCOMA, 2002, 11 (06) : 511 - 516
  • [40] Test-retest variability in visual field testing using frequency doubling technology
    Horani, A.
    Frenkel, S.
    Blumenthal, E. Z.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (02) : 203 - 207