Realigning the Nile River to provide cooling water to a power plant

被引:0
|
作者
Khondker, SA
ElDesouky, I
Kanakaris, GA
机构
关键词
D O I
暂无
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The Egyptian Electric Authority (EEA) is constructing a two-unit (2x600 MW) thermal power plant with a provision to build a total of four units (4x600 MW) on the east (right) bank of the Nile River near El-Kureimat, about 90 km south of Cairo. The total cooling water requirement is 80 cubic meter per second (m(3)/s). A site visit in 1992 revealed that the available now depth in front of the selected intake canal was not adequate to provide required cooling water. After considering various concepts of open canal, it was decided to realign the Nile River locally to increase the now depth in front of the intake. A movable bed scale model was built at the Hydraulic & Sediment Research Institute (HSRI) in Delta Barrage, Egypt to investigate various concepts of deflecting structures and training works. A unique solution was eventually obtained by reshaping the existing island in front of the proposed intake to provide a wider opening between the island and the right bank to increase the flow along the right bank to assure continuous supply of cooling water.
引用
收藏
页码:238 / 245
页数:2
相关论文
共 50 条
  • [41] Water Quality Modeling of a Power Generating Plant's Cooling Reservoir
    Samothrakis, Periandros
    Zheng, Yifan
    Ng, Kit
    WORLD ENVIRONMENTAL AND WATER RESOURCES CONGRESS 2019: HYDRAULICS, WATERWAYS, AND WATER DISTRIBUTION SYSTEMS ANALYSIS, 2019, : 348 - 354
  • [42] Hydraulic Balancing of the Cooling Water System of a Pumped Storage Power Plant
    Georgescu, Sanda-Carmen
    Bucur, Diana Maria
    Dunca, Georgiana
    Georgescu, Andrei-Mugur
    Nicolae, Alina Alexandrina
    Ciuc, Petre-Ovidiu
    2017 8TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT (CIEM), 2017, : 246 - 250
  • [43] ECOLOGICAL EFFECTS OF COOLING WATER OF A POWER-PLANT AT KIEL FJORD
    MOLLER, H
    MEERESFORSCHUNG-REPORTS ON MARINE RESEARCH, 1978, 26 (3-4): : 117 - 130
  • [44] REUSING POWER-PLANT COOLING WATER TO REDUCE MAIN BREAKS
    WETTERING, LA
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1985, 77 (11): : 47 - 52
  • [45] A CONVENIENT ARRANGEMENT OF SECONDARY COOLING WATER SYSTEM IN POWER PLANT UNITS
    MEYERKAHRWEG, H
    BRENNSTOFF-WARME-KRAFT, 1970, 22 (05): : 239 - +
  • [46] REUSING POWER PLANT COOLING WATER TO REDUCE MAIN BREAKS.
    Wettering, Lawrence A.
    1600, (77):
  • [47] Design of the reclaimed water reuse project for recirculating cooling water in a thermal power plant
    Pang, Hui-Cong
    Zhang, Can-Can
    Gao, Tai-Zhong
    SUSTAINABLE DEVELOPMENT OF URBAN AND RURAL AREAS, 2014, 507 : 688 - 692
  • [48] Water bankruptcy in the mighty Nile river basin
    Degefu, Dagmawi Mulugeta
    He, Weijun
    SUSTAINABLE WATER RESOURCES MANAGEMENT, 2016, 2 (01) : 29 - 37
  • [49] Exploitation of water and hydropower resources of the Nile river
    Novozhenin V.D.
    Lapshin A.M.
    Hydrotechnical Construction, 2000, 34 (8-9) : 457 - 463
  • [50] Hydropolitics in Water Governance of the Nile River in Africa
    Kansal, Mitthan Lal
    Ekadu, Silas
    WORLD ENVIRONMENTAL AND WATER RESOURCES CONGRESS 2018: INTERNATIONAL PERSPECTIVES, HISTORY AND HERITAGE, EMERGING TECHNOLOGIES, AND STUDENT PAPERS, 2018, : 277 - 290