The efficacy of contrast-enhanced harmonic endoscopic ultrasonography in diagnosing gallbladder cancer

被引:16
|
作者
Sugimoto, Mitsuru [1 ]
Takagi, Tadayuki [1 ]
Konno, Naoki [1 ]
Suzuki, Rei [1 ]
Asama, Hiroyuki [1 ]
Hikichi, Takuto [2 ]
Watanabe, Ko [1 ,2 ]
Waragai, Yuichi [1 ,2 ]
Kikuchi, Hitomi [1 ]
Takasumi, Mika [1 ]
Ohira, Hiromasa [1 ]
机构
[1] Fukushima Med Univ, Sch Med, Dept Gastroenterol & Rheumatol, Fukushima, Japan
[2] Fukushima Med Univ Hosp, Dept Endoscopy, Fukushima, Japan
来源
SCIENTIFIC REPORTS | 2016年 / 6卷
关键词
MULTIDETECTOR COMPUTED-TOMOGRAPHY; SMALL POLYPOID LESIONS; DIFFERENTIAL-DIAGNOSIS; EUS; PANCREATITIS; TUMORS;
D O I
10.1038/srep25848
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to review the efficacy of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) in diagnosing gallbladder (GB)-protruded lesions. Thirty-eight patients underwent CH-EUS for the diagnosis of GB-protruded lesions. Twenty-four patients whose major axes of their largest lesions were longer than 10 mm were recruited. The ability of CH-EUS to diagnose malignant or benign lesions was reviewed. We treated lesions with brindled enhanced patterns as malignant and those with uniformly enhanced or unenhanced patterns as benign. Furthermore, three gastroenterologists who were not familiar with pancreaticobiliary EUS compared the diagnostic abilities of CH-EUS and conventional EUS using photographs. The sensitivity, specificity, and malignant accuracy of CH-EUS were 100, 94.4, and 95.8%, respectively. The number of lesions that presented with enhanced patterns was significantly different between the malignant lesions and the benign lesions (P < 0.001). In the comparison of diagnostic abilities between CH-EUS and conventional EUS by the three gastroenterologists, CH-EUS was significantly superior to conventional EUS in terms of sensitivity, specificity, and accuracy (76.1 vs. 42.9%, P = 0.029; 66.7 vs. 39.2%, P = 0.005; and 69.4 vs. 40.3%, P < 0.001; respectively). In conclusion, CH-EUS was useful for diagnosing malignant and benign GB-protruded lesions.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Tumor Vessel Depiction With Contrast-Enhanced Endoscopic Ultrasonography Predicts Efficacy of Chemotherapy in Pancreatic Cancer
    Yamashita, Yasunobu
    Ueda, Kazuki
    Itonaga, Masahiro
    Yoshida, Takeichi
    Maeda, Hiroki
    Maekita, Takao
    Iguchi, Mikitaka
    Tamai, Hideyuki
    Ichinose, Masao
    Kato, Jun
    PANCREAS, 2013, 42 (06) : 990 - 995
  • [42] Contrast-enhanced endoscopic ultrasonography in digestive diseases
    Yoshiki Hirooka
    Akihiro Itoh
    Hiroki Kawashima
    Eizaburo Ohno
    Yuya Itoh
    Yosuke Nakamura
    Takeshi Hiramatsu
    Hiroyuki Sugimoto
    Hajime Sumi
    Daijiro Hayashi
    Naoki Ohmiya
    Ryoji Miyahara
    Masanao Nakamura
    Kohei Funasaka
    Masatoshi Ishigami
    Yoshiaki Katano
    Hidemi Goto
    Journal of Gastroenterology, 2012, 47 : 1063 - 1072
  • [43] Contrast-enhanced endoscopic ultrasonography in digestive diseases
    Hirooka, Yoshiki
    Itoh, Akihiro
    Kawashima, Hiroki
    Ohno, Eizaburo
    Itoh, Yuya
    Nakamura, Yosuke
    Hiramatsu, Takeshi
    Sugimoto, Hiroyuki
    Sumi, Hajime
    Hayashi, Daijiro
    Ohmiya, Naoki
    Miyahara, Ryoji
    Nakamura, Masanao
    Funasaka, Kohei
    Ishigami, Masatoshi
    Katano, Yoshiaki
    Goto, Hidemi
    JOURNAL OF GASTROENTEROLOGY, 2012, 47 (10) : 1063 - 1072
  • [44] RETRACTED ARTICLE: Meta-analysis of contrast-enhanced ultrasound and contrast-enhanced harmonic endoscopic ultrasound for the diagnosis of gallbladder malignancy
    Xue Liang
    Xiang Jing
    BMC Medical Informatics and Decision Making, 20
  • [45] Contrast-Enhanced Endoscopic Ultrasonography for Pancreatic Tumors
    Yamashita, Yasunobu
    Kato, Jun
    Ueda, Kazuki
    Nakamura, Yasushi
    Kawaji, Yuki
    Abe, Hiroko
    Nuta, Junya
    Tamura, Takashi
    Itonaga, Masahiro
    Yoshida, Takeichi
    Maeda, Hiroki
    Maekita, Takao
    Iguchi, Mikitaka
    Tamai, Hideyuki
    Ichinose, Masao
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [46] Retraction Note: Meta-analysis of contrast-enhanced ultrasound and contrast-enhanced harmonic endoscopic ultrasound for the diagnosis of gallbladder malignancy
    Xue Liang
    Xiang Jing
    BMC Medical Informatics and Decision Making, 22
  • [47] Contrast-enhanced harmonic endoscopic ultrasonography for predicting the efficacy of first-line gemcitabine and nab-paclitaxel chemotherapy in pancreatic cancer
    Emori, Tomoya
    Ashida, Reiko
    Tamura, Takashi
    Kawaji, Yuki
    Hatamaru, Keiichi
    Itonaga, Masahiro
    Yamashita, Yasunobu
    Shimokawa, Toshio
    Higashino, Nobuyuki
    Ikoma, Akira
    Sonomura, Tetsuo
    Kawai, Manabu
    Kitano, Masayuki
    PANCREATOLOGY, 2022, 22 (04) : 525 - 533
  • [48] Quantitative Perfusion Analysis of Contrast-Enhanced Harmonic Endoscopic Ultrasonography in Solid Lesions of the Pancreas
    Fukasawa, Mitsuharu
    Takano, Shinichi
    Kadokura, Makoto
    Takahashi, Ei
    Sato, Tadashi
    Enomoto, Nobuyuki
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 132 - 132
  • [49] Characterization of Pancreatic Tumors with Quantitative Perfusion Analysis in Contrast-Enhanced Harmonic Endoscopic Ultrasonography
    Omoto, Shunsuke
    Takenaka, Mamoru
    Kitano, Masayuki
    Miyata, Takeshi
    Kamata, Ken
    Minaga, Kosuke
    Arizumi, Tadaaki
    Yamao, Kentaro
    Imai, Hajime
    Sakamoto, Hiroki
    Harwani, Yogesh
    Sakurai, Toshiharu
    Watanabe, Tomohiro
    Nishida, Naoshi
    Takeyama, Yoshifumi
    Chiba, Yasutaka
    Kudo, Masatoshi
    ONCOLOGY, 2017, 93 : 55 - 60
  • [50] Interobserver agreement of contrast-enhanced harmonic endoscopic ultrasonography in the evaluation of solid pancreatic lesions
    Soares, Joao-Bruno
    Iglesias-Garcia, Julio
    Goncalves, Bruno
    Lindkvist, Bjorn
    Larino-Noia, Jose
    Bastos, Pedro
    Caetano, Ana Celia
    Ferreira, Anbal
    Pimentel-Nunes, Pedro
    Lopes, Luis
    Moutinho, Pedro
    Enrique Dominguez-Munoz, J.
    ENDOSCOPY INTERNATIONAL OPEN, 2015, 3 (03) : E205 - E209