Dynamic modeling of a water tube boiler

被引:4
|
作者
Jha, R. S. [1 ,2 ]
Lele, Mandar M. [1 ]
机构
[1] Dr Vishwanath Karad MIT World Peace Univ, Sch Mech Engn, Pune, Maharashtra, India
[2] Thermax Ltd, Heating, Innovat, Pune, Maharashtra, India
关键词
circulation; condensation enthalpy; downcomer; drift velocity; drum; dryness fraction; rate of condensation; riser; steam volume fraction; void fraction;
D O I
10.1002/htj.22581
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present work aims to develop an integrated heat transfer and hydrodynamic model for the study of boiler dynamics in fluctuating load conditions. A transient heat transfer model has been developed to estimate water side heat transfer and it is directly integrated with the hydrodynamic model. Two independent natural circulation circuits for furnace water wall and convection tube bank have been considered due to differences in heat transfer, dryness fraction, and void fraction. The transient heat transfer model calculates the heat transfer and water wall temperature of the various sections to calculate total gas side heat transfer, gas temperature profile, and waterside heat transfer in the furnace water wall and convection tube bank. Mass momentum and energy conservation equations are generated for both natural circulation circuits using the estimated value of waterside heat transfer of the transient heat transfer model. These equations are integrated with mass and energy conservation equations for the drum below water level and drum above water level to generate a system of equations to estimate drum pressure and water level fluctuation. This model has been extended for boiler feedback control systems, including the load management and the water level control system.
引用
收藏
页码:6087 / 6121
页数:35
相关论文
共 50 条
  • [41] Research on Dynamic Water Level Model Based on Supercharged Boiler
    Zhu, Qidan
    Leng, Xin
    Lei, Yanmin
    Liu, Gang
    2008 INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION: (ICMA), VOLS 1 AND 2, 2008, : 391 - +
  • [42] COMBUSTION OF CWSF IN A 1000 LB/H STEAM WATER-TUBE BOILER
    MILLER, BG
    WINCEK, RT
    SCARONI, AW
    KINNEMAN, WP
    JENKINS, RG
    13TH INTERNATIONAL CONFERENCE ON COAL AND SLURRY TECHNOLOGY, 1988, : 119 - 129
  • [43] ACOUSTIC EMISSION DETECTION AND SIGNAL SOURCE ANALYSIS OF BOILER WATER WALL TUBE
    Yuan, Yilin
    Shen, Gongtian
    Shen, Yongna
    Zhang, Wenjun
    Wan, Qiang
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 13, 2021,
  • [44] An Overheat Boiler Tube Failure
    Perdomo, J. J.
    Spry, T. D.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2005, 5 (02) : 25 - 28
  • [45] FIRE-TUBE BOILER
    MOORE, BR
    ENGINEERING, 1978, 218 (07): : 681 - 683
  • [46] DEVELOPMENT AND INVESTIGATION OF A HOT WATER TUBE CONTACT BOILER FOR CENTRALIZED HEAT SUPPLY
    YAKIMOV, OL
    LYAKHOV, OG
    THERMAL ENGINEERING, 1974, 21 (06) : 115 - 119
  • [47] Failure analysis of the water-wall tube in KIVCET waste heat boiler
    Li, Jiadong
    Zhou, Ping
    Yu, Gang
    Yan, Hongjie
    Chen, Zhuo
    Song, Guomeng
    Liao, Zhou
    ENGINEERING FAILURE ANALYSIS, 2021, 121
  • [48] FIRE-TUBE BOILER
    FOX, GR
    ENGINEERING, 1978, 218 (12): : 1281 - 1281
  • [49] ANALYSIS OF THE REASONS FOR THE LEAKAGE OF A BOILER WATER-WALL TUBE IN A POWER PLANT
    Guo, Ruidong
    Xue, Song
    Yang, Tao
    Liu, Xuedong
    MATERIALI IN TEHNOLOGIJE, 2020, 54 (02): : 221 - 226
  • [50] The optimization of design of fire-tube shell hot-water boiler
    Naumejko, A.V.
    Ryzhkov, A.F.
    Gofman, M.S.
    Dejnezhenko, V.I.
    Promyshlennaya Energetika, 2002, (10): : 37 - 41