Dose calculation validation of VMC++ for photon beams

被引:27
|
作者
Gardner, J. [1 ]
Siebers, J.
Kawrakow, I.
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1118/1.2714473
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The radiation therapy specific Voxel Monte Carlo (VMC++) dose calculation algorithm achieves a dramatic improvement in MC dose calculation efficiency for radiation therapy treatment planning dose evaluation compared with other MC algorithms. This work aims to validate VMC++ for radiation therapy photon beam planning. VMC++ was validated with respect to the well-benchmarked EGS-based DOSXYZnrc by comparing depth dose and lateral profiles for field sizes ranging from I x 1 to 40 x 40 cm(2) for 6 and 18 MV beams in a homogeneous water phantom and in a simulated bone-lung-bone phantom. Patient treatment plan dose distributions were compared for five prostate plans and five head-and-neck (H/N) plans, all using intensity-modulated radiotherapy beams. For all tests, the same incident particles were used in both codes to isolate differences due to modeling of the radiation source. Voxel-by-voxel observed differences were analyzed to distinguish between systematic and purely statistical differences. Dose-volume-histogram-derived dose indices were compared for the patient plans. For the homogeneous water phantom and the bone-lung-bone phantom, the depth dose curve predicted by VMC++ agreed with that predicted by DOSXYZnrc within expected statistical uncertainty in all voxels except the surface voxel of the water phantom, where VMC++ predicted a lower dose. When the electron cutoff parameter was decreased for both codes, the surface voxel agreed within expected statistical uncertainty. For prostate plans, the most severe difference between the codes resulted in 55% of the voxels showing a systematic difference of 0.32% of maximum dose. For H/N plans, the largest difference observed resulted in 2% of the voxels showing a systematic difference of 0.98% of maximum dose. For the prostate plans, the most severe difference in the planning target volume D-95 was 0.4%, the rectum D-35 was 0.2%, the rectum D-17 was 0.2%, the bladder D-50 was 0.3% and the bladder D-25 was 0.3%. For the H/N plans, the most severe difference in the gross tumor volume D-98 was 0.4%, the clinical target volume D-90 was 0.2%, the nodes D-90 was 0.2%, the parotids D-95 was 0.8%, and the cord D-2 was 0.8%. All of these differences are clinically insignificant. VMC++ showed an average efficiency gain over DOSXYZnrc of at least an order of magnitude without introducing significant systematic bias. VMC++ can be used for photon beam MC patient dose computations without a clinically significant loss in accuracy. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1809 / 1818
页数:10
相关论文
共 50 条
  • [1] Fast treatment head simulations for photon beams using VMC++
    Kawrakow, I
    MEDICAL PHYSICS, 2004, 31 (06) : 1770 - 1770
  • [2] VMC++ versus BEAMnrc: A comparison of simulated linear accelerator heads for photon beams
    Hasenbalg, F.
    Fix, M. K.
    Born, E. J.
    Mini, R.
    Kawrakow, I.
    MEDICAL PHYSICS, 2008, 35 (04) : 1521 - 1531
  • [3] VMC++, a MC algorithm optimized for electron and photon beam dose calculations for RTP
    Kawrakow, I
    Fippel, M
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1490 - 1493
  • [4] Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    Fippel, M
    MEDICAL PHYSICS, 1999, 26 (08) : 1466 - 1475
  • [5] Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    Abt. für Medizinische Physik, Univ. Klin. Tübingen, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany
    Med. Phys., 8 (1466-1475):
  • [6] Implementation of Monte Carlo code VMC++ for photon beam treatment planning
    Tillikainen, L.
    Siljamaki, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2293 - 2293
  • [7] VMC++, electron and photon Monte Carlo calculations optimized for radiation treatment planning
    Kawrakow, I
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 229 - 236
  • [8] Validation of a commercial TPS based on the VMC++ Monte Carlo code for electron beams: Commissioning and dosimetric comparison with EGSnrc in homogeneous and heterogeneous phantoms
    Ferretti, A.
    Martignano, A.
    Simonato, F.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 25 - 35
  • [9] VMC plus plus Validation for photon beams in the energy range of 20-1000 keV
    Terribilini, Dario
    Fix, Michael K.
    Frei, Daniel
    Volken, Werner
    Manser, Peter
    MEDICAL PHYSICS, 2010, 37 (10) : 5218 - 5227
  • [10] Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams
    Vassiliev, Oleg N.
    Wareing, Todd A.
    McGhee, John
    Failla, Gregory
    Salehpour, Mohammad R.
    Mourtada, Firas
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03): : 581 - 598