Continuous flow system for lead determination by faas in spirituous beverages with solid phase extraction and on-line copper removal

被引:30
|
作者
de Peña, YP
Paredes, B
Rondón, W
Burguera, M
Burguera, JL
Rondón, C
Carrero, P
Capote, T
机构
[1] Univ Los Andes, Fac Ciencias, Dept Quim, Lab Espectroscopia Mol, Merida 5101 A, Venezuela
[2] Univ Ctr Occidental Lisandro Alvarado, Dept Quim & Suelos, Unidad Anal Instrumental, Decanato Agr, Barquisimeto, Venezuela
关键词
flame atomic absorption spectrometry; continuous flow system; synthetic zeolite; lead; alcoholic drinks; copper removal; spirituous beverages;
D O I
10.1016/j.talanta.2004.05.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous flow system for the determination of lead in home made spirituous beverages was developed. The determination was based on the formation of a neutral chelate of the element with ammonium pyrrolidine dithiocarbamate, its adsorption onto a minicolumn packed with sodium faujasite type Y synthetic zeolite, followed by elution with methyl isobutyl ketone and determination by flame atomic absorption spectrometry. Ethanol and copper interfere strongly in the determination and therefore, must be separated prior to the analysis. Copper is removed by precipitation with rubeanic acid, while ethanol is eliminated by rotaevaporation. Sample solutions containing Pb2+ in the concentration range from 5 to 120 mug = l(-1) at pH 2.5 could be analyzed, by using a preconcentration time of 3 min. Preconcentration factors from 80 to 140 were achieved for a sample volume of 6 ml and the detection limit varied from 1.4 to 3.5 mug l(-1), depending on the matrix composition. The relative standard deviations for 60 mug l(-1) Pb was 3.2% (n = 10) and the recovery of spikes (20, 40, 60 and 80 mug l(-1)) added to the samples was estimated within 92-105% range, suggesting that lead can be quantitatively determined in such samples. Determining lead in several samples by an alternative technique further checked the accuracy. Finally, the concentrations of Pb2+ determined in 28 samples of Venezuelan spirituous beverages were in 12.6-370.0 mug l(-1) range, depending on the fermenting material based on different mixtures of agave, raw sugar cane and white sugar. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1351 / 1358
页数:8
相关论文
共 50 条
  • [31] Determination of lead by on-line solid phase extraction using a PTFE micro-column and flame atomic absorption spectrometry
    Zachariadis, GA
    Anthemidis, AN
    Bettas, PG
    Stratis, JA
    TALANTA, 2002, 57 (05) : 919 - 927
  • [32] On-line flow injection solid phase extraction using imprinted polymeric nanobeads for the preconcentration and determination of mercury ions
    Rajabi, Hamid Reza
    Shamsipur, Mojtaba
    Zahedi, Mir Mandi
    Roushani, Mahmoud
    CHEMICAL ENGINEERING JOURNAL, 2015, 259 : 330 - 337
  • [33] Molecularly imprinted on-line solid-phase extraction combined with flow-injection chemiluminescence for the determination of tetracycline
    Xiong, Yan
    Zhou, Houjiang
    Zhang, Zhujun
    He, Deyong
    He, Chao
    ANALYST, 2006, 131 (07) : 829 - 834
  • [34] Flow-injection on-line oxidizing fluorimetry and solid phase extraction for determination of thioridazine hydrochloride in human plasma
    Zhang, Zhi-Qi
    Ma, Han
    Lei, Ying
    Lu, Yue-Mei
    TALANTA, 2007, 71 (05) : 2056 - 2061
  • [35] On-Line Solid Phase Extraction and Spectrophotometric Detection with Flow Technique for the Determination of Nanomolar Level Ammonium in Seawater Samples
    Chen, Guohe
    Zhang, Min
    Zhang, Zhen
    Huang, Yongming
    Yuan, Dongxing
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 310 - 326
  • [36] Automatic on-line pre-concentration system using a knotted reactor for the FAAS determination of lead in drinking water
    Souza, Anderson S.
    Brandao, Geovani C.
    dos Santos, Walter N. L.
    Lemos, Valfredo A.
    Ganzarolli, Edgard M.
    Bruns, Roy E.
    Ferreira, Sergio L. C.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 141 (03) : 540 - 545
  • [37] On-line solid phase extraction and determination of copper in food samples using polyurethane foam loaded with Me-BTANC
    Lemos, VA
    de Jesus, AA
    Gama, EM
    David, GT
    Yamaki, RT
    ANALYTICAL LETTERS, 2005, 38 (04) : 683 - 696
  • [38] Synthesis and application of XAD-2/Me-BTAP resin for on-line solid phase extraction and determination of trace metals in biological samples by FAAS
    Azevedo Lemos, Valfredo
    Teixeira David, Graciete
    Santos, Luana Novaes
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (04) : 697 - 704
  • [39] Flow injection determination of copper in mussels by flame atomic absorption spectrometry after on-line continuous ultrasound-assisted extraction
    Moreno-Cid, A
    Yebra, MC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (05) : 967 - 974
  • [40] A Flow-Injection On-line Solid Phase Extraction, Enrichment System for Determination of Melamine in Milk Products Based on High Performance Liquid Chromatography
    Li Yong-Sheng
    Liang Qin-Qin
    Hou Yan-Qiu
    Li Hong-Xing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (02) : 298 - 303