Aortic and supra-aortic arterial tortuosity and access technique: Impact on time to device deployment in stroke thrombectomy

被引:6
|
作者
Rosa, Joao Alves [1 ]
Roberts, Rachel [1 ]
Wareham, James [1 ]
Crossley, Robert [1 ]
Cox, Anthony [1 ]
Mortimer, Alex [1 ]
机构
[1] Southmead Hosp, North Bristol NHS Trust, Dept Neuroradiol, Southmead Rd, Bristol BS10 5NB, Avon, England
关键词
Thrombectomy; stroke; anatomy; time; reperfusion;
D O I
10.1177/1591019920974183
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Longer intervals to reperfusion in patients treated with mechanical thrombectomy (MT) for emergent large vessel occlusion (ELVO) stroke are associated with worse outcomes and influenced by the operator's ability to navigate individual anatomy. Our aims were to assess the impact of time from puncture to first deployment of the MT device (DT) on technical and clinical outcomes, develop an Anatomical Assessment for Mechanical Thrombectomy Score (ASMETS) that could predict DT and assess how different methods of intracranial access (coaxial-direct or exchange) influence this. Methods Retrospective review of a prospective database of patients treated with MT for ELVO between November 2015 and August 2018. CTAs were assessed for ASMETS. Intracranial access technique was at the discretion of the operator. Technical and clinical outcomes and complications were recorded. Linear and logistic regression analysis was performed. Results 92 patients were included. The impact of DT on clinical outcomes was significant. An unfavourable ASMET score is significantly associated with longer DT (p = 0.002) and linear regression showed DT time can be predicted by ASMETS - F(1,90) = 6.182, p = 0.015. No difference was demonstrated between different access techniques. Conclusion CTA-based ASMETS can predict time between arterial puncture and deployment of the mechanical thrombectomy device in stroke patients, irrespective of the technique used to catheterise the target ICA. This could inform the operator in preparing appropriate strategies to overcome challenging vascular anatomy in patients undergoing MT.
引用
收藏
页码:419 / 426
页数:8
相关论文
共 50 条
  • [21] Combined Angioplasty Technique of the Carotid Territory and Supra-Aortic Trunk by Double Access (Cervical and Limbs) for Tandem Lesions
    Ribeiro, Felipe S.
    Casella, Ivan Benaduce
    Diamante Leiderman, Dafne Braga
    Puech-Leao, Pedro
    De Luccia, Nelson
    ANNALS OF VASCULAR SURGERY, 2020, 68 : 570.e9 - 570.e15
  • [22] Angioplasty and stenting of solitary supra-aortic artery and aortoplasty by kissing balloon technique
    Karthik, R
    Abraham, KA
    Henry, M
    Sudarsana, G
    Chandrasekar, B
    Sriram, R
    JOURNAL OF INVASIVE CARDIOLOGY, 1999, 11 (06): : 375 - 378
  • [23] Thoracic Endovascular Aortic Repair with Supra-Aortic Trunk Revascularization is Associated with Increased Risk of Periprocedural Ischemic Stroke
    Li, Ruojia Debbie
    Chia, Matthew C.
    Eskandari, Mark K.
    ANNALS OF VASCULAR SURGERY, 2022, 87 : 205 - 212
  • [24] Identification of proximal landing zone limit for proper deployment of aortic arch stentgraft after supra-aortic great vessels transposition
    Serag, A. R.
    Bergeron, P.
    Mathieu, X.
    Piret, V.
    Petrosyan, A.
    Gay, J.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2007, 48 (06): : 805 - 807
  • [25] Supra-aortic arterial stenoses: Management with Palmaz balloon-expandable intraluminal stents
    Lyon, RD
    Shonnard, KM
    McCarter, DL
    Hammond, SL
    Ferguson, D
    Rholl, KS
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (06) : 825 - 835
  • [26] A modified frozen elephant trunk hybrid device to facilitate supra-aortic trunk anastomosis
    Masiello, Paolo
    Mastrogiovanni, Generoso
    Chivasso, Pierpaolo
    Triggiani, Donato
    Cafarelli, Francesco
    Iesu, Severino
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (01) : 371 - 373
  • [27] Impact of clinical training on supra-aortic duplex and transcranial doppler examination concordance
    Egido, Jose A.
    Garcia, Ana M.
    del Prado-Gonzalez, Nayade
    Fuentes-Ferrer, Manuel
    Lopez-Herranz, Marta
    Simal-Hernandez, Patricia
    Fernandez-Perez, Cristina
    JOURNAL OF CLINICAL ULTRASOUND, 2016, 44 (09) : 571 - 579
  • [28] A Novel Fenestrating Device: Quick Fenestrater for Reconstructing Supra-aortic Arteries In Situ During Thoracic Endovascular Aortic Repair
    Bai, Jun
    Wang, Chao
    Liu, Yandong
    Jin, Jie
    Wu, Jianjin
    Ji, Xiangguo
    Qu, Lefeng
    CANADIAN JOURNAL OF CARDIOLOGY, 2021, 37 (10) : 1539 - 1546
  • [29] COMPARATIVE ROENTGENOLOGICAL EMBRYOLOGY OF SUPRA-AORTIC ARTERIES OF DOMESTIC MAMMALS WITH A PRENATAL ANGIOGRAPHIC TECHNIQUE
    STOETER, P
    PETERSEN, D
    VOIGT, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1977, 126 (02): : 150 - 156
  • [30] Management of Inadvertent Supra-aortic Arterial Lesions During Central Venous Access Procedures: Report of Six Cases and Proposed Algorithm
    Gabriele, Pagliariccio
    Emanuele, Gatta
    Ilenia, Di Sario
    Carlo, Gnilli Cicilioni
    Luca, Felici
    Luciano, Carbonari
    ANNALS OF VASCULAR SURGERY, 2021, 75 : 308 - 314