Pump and pipeline performance when pumping slurries with different particle gradings

被引:3
|
作者
Sellgren, Anders [1 ]
Visintainer, Robert [2 ,3 ]
Furlan, John [2 ,3 ]
Matousek, Vaclav [4 ]
机构
[1] Lulea Univ Technol, Lulea, Sweden
[2] GIW Ind, Dept Engn, Grovetown, GA USA
[3] GIW Ind, R&D, Grovetown, GA USA
[4] Czech Tech Univ, CR-16635 Prague, Czech Republic
来源
关键词
slurry friction loss; multi-component modelling; pump performance derating;
D O I
10.1002/cjce.22489
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A pipeline slurry friction loss model consisting of three regimes was initially proposed by Wilson then extended to four components consisting of fluid, pseudo-homogeneous, heterogeneous, and fully stratified regimes. The weighting technique using up to four regime-related components often works well for friction loss estimations based on simple input data and model parameters. This also holds for the Hydraulic Institute's pump performance derating procedure for settling slurries. The comparisons and discussion focus on coarse particle slurries and some cases where the modelling estimations for pipeline and pump performance were not particularly accurate.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 50 条
  • [41] DYNAMIC PUMPING PERFORMANCE OF THE HEMOPUMP(R) - A SMALL INTRAVENTRICULAR BLOOD PUMP
    KUNST, EE
    VANALSTE, JA
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (08): : 493 - 498
  • [42] Effect of pumping chamber on performance of non-overload centrifugal pump
    Yun-qing Gu
    Jie-gang Mou
    Dong-shun Dai
    Shui-hua Zheng
    Deng-hao Wu
    Lan-fang Jiang
    Han-yu Shi
    Evan Wang
    Journal of Central South University, 2015, 22 : 2989 - 2997
  • [43] Performance prediction for large low-head pump and pumping installation
    Li, Yanjun
    Yan, Dengfeng
    Yuan, Shouqi
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2007, 38 (10): : 36 - 40
  • [44] A Study on the Pumping Performance of a Helical-type Molecular Drag Pump
    Kim, Do-Haeng
    Kwon, Myoung-Keun
    Hwang, Young-Kyu
    RAREFIED GAS DYNAMICS, 2009, 1084 : 1141 - 1146
  • [45] Effect of pumping chamber on performance of non-overload centrifugal pump
    谷云庆
    牟介刚
    代东顺
    郑水华
    吴登昊
    蒋兰芳
    施瀚昱
    WANG Evan
    Journal of Central South University, 2015, 22 (08) : 2989 - 2997
  • [46] DIFFERENT SIMULATION MODELS IN EXEMPLARY EMPLOYMENT FOR "PUMP AGGREGATE - PIPELINE" SYSTEMS
    Koziorowska, Anna
    Bartman, Jacek
    ECT 2009: ELECTRICAL AND CONTROL TECHNOLOGIES, 2009, : 135 - 138
  • [47] Impacts of different diameter combinations on the temperature of a crude oil pipeline when colocating with a products pipeline
    Yu B.
    Shi Y.
    Liu X.
    Zhang J.
    Wei J.
    Frontiers of Energy and Power Engineering in China, 2010, 4 (2): : 192 - 197
  • [48] Correcting rated pump performance improves heavy oil pipeline efficiency
    Yu, Yang
    Wu, Changchun
    Xing, Xiaokai
    Shi, Yangchen
    Li, Yanping
    Zuo, Lili
    OIL & GAS JOURNAL, 2014, 112 (07) : 108 - +
  • [49] Experimental Study of Loss Coefficients of Hydraulic Parameters for a Centrifugal Pump when Pumping Viscous Liquids
    Poursharifi, Zahra
    Bonab, Mir Buyuk Ehghaghi
    Majidi, Seyyed Hojjat
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2012, 39 (01) : 75 - 84
  • [50] The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
    Zhang, Bowen
    Cheng, Li
    Xu, Chunlei
    Wang, Mo
    ENERGIES, 2021, 14 (04)