Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils

被引:1
|
作者
Masaryk, AM
Frayne, R
Unal, O
Rappe, AH
Strother, CM
机构
[1] Univ Arizona, Ctr Hlth Sci, Dept Radiol, Tucson, AZ 85724 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Phys Med, Madison, WI 53706 USA
[4] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[5] Univ Calgary, Dept Radiol, Calgary, AB, Canada
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Previous studies have depicted arterial and aneurysmal anatomy with three-dimensional time-of-flight (3D-TOF) MR angiography before and after treatment with Guglielmi detachable coils (GDCs) and with CT angiography before and after treatment with stents and stent-grafts, We investigated the ability of time-resolved contrast-enhanced SD MR angiography (3D MR digital subtraction angiography [DSA]) to accurately depict the anatomy of experimental lateral aneurysms before and after treatment with GDCs and a variety of stents or stent-grafts, and compared these findings with 3D-TOF MR angiography without and with contrast enhancement and CT angiography. METHODS: Two nitinol stents, two nitinol-polytetrafluoroethylene (PTFE) stent-grafts, and two stainless steel stents were deployed in three dogs with experimental carotid aneurysms, In a fourth animal, one of three aneurysms was completely occluded with GDCs, The other two aneurysms were loosely packed to ensure persistence of some residual aneurysmal lumen. Cut-film angiography, CT angiography, 3D-TOF MR angiography without and with contrast enhancement, and 3D MR DSA were performed in all dogs before and 3 weeks after treatment. RESULTS: SD MR DSA was superior to conventional SD-TOF MR angiography without and with contrast enhancement in accurately depicting experimental lateral aneurysms and superior to CT angiography in depicting aneurysms treated by GDCs, SD MR DSA and CT angiography were comparable in depicting vessels treated with nitinol stents and stent-grafts, whereas CT angiography was superior for showing vessels treated by stainless steel stents. CONCLUSION: We recommend further development and clinical evaluation of 3D MR DSA For imaging cerebral aneurysms before and after treatment with GDCs, 3D MR DSA or CT angiography may be useful for evaluating vessels containing nitinol stents or nitinol-PTFE stent-grafts, whereas CT angiography should be used for follow-up of vessels treated by stainless steel stents.
引用
收藏
页码:1523 / 1531
页数:9
相关论文
共 50 条
  • [31] MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms
    Manfred Cejna
    Christian Loewe
    Maria Schoder
    Albert Dirisamer
    Thomas Hölzenbein
    Georg Kretschmer
    Johannes Lammer
    Siegfried Thurnher
    European Radiology, 2002, 12 : 2443 - 2450
  • [32] MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms
    Cejna, M
    Loewe, C
    Schoder, M
    Dirisamer, A
    Hölzenbein, T
    Kretschmer, G
    Lammer, J
    Thurnher, S
    EUROPEAN RADIOLOGY, 2002, 12 (10) : 2443 - 2450
  • [33] Subtraction CT angiography in the follow-up of treated cerebral aneurysms
    Meijer, Frederick J. A.
    van Maren, Emiel A.
    Boogaarts, Hieronymus D.
    NEURORADIOLOGY, 2019, 61 (07) : 735 - 736
  • [34] Subtraction CT angiography in the follow-up of treated cerebral aneurysms
    Frederick J. A. Meijer
    Emiel A. van Maren
    Hieronymus D. Boogaarts
    Neuroradiology, 2019, 61 : 735 - 736
  • [35] Angiographic follow-up of cerebral aneurysms treated with Guglielmi detachable coils(GDCs): An analysis of 162 cases of 173 aneurysms
    Giuseppe Scotti
    介入放射学杂志, 2005, (05) : 472 - 479
  • [36] Follow-up of intracranial aneurysms treated with detachable coils: Comparison of gadolinium-enhanced 3D time-of-flight MR angiography and digital subtraction angiography
    Boulin, A
    Pierot, L
    RADIOLOGY, 2001, 219 (01) : 108 - 113
  • [37] MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils
    Kähärä, VJ
    Seppänen, SK
    Ryymin, PS
    Mattila, P
    Kuurne, T
    Laasonen, EM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (08) : 1470 - 1475
  • [38] Cerebral aneurysm embolized with Guglielmi detachable coils evaluation with MR-angiography
    Aprile, I
    Biasizzo, E
    Lavaroni, A
    Petralia, B
    DeColle, MC
    Iaiza, F
    Fabris, G
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 140 - 141
  • [39] Follow-up of intracranial aneurysms selectively treated with coils: Prospective evaluation of contrast-enhanced MR angiography
    Pierot, L
    Delcourt, C
    Bouquigny, F
    Breidt, D
    Feuillet, B
    Lanoix, O
    Gallas, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (04) : 744 - 749
  • [40] Magnetic resonance angiography (MRA) of intracranial aneurysms treated with Guglielmi detachable coils: Our experience in 103 cases
    Villanua, JA
    Masso, J
    Larrea, JA
    Recondo, JA
    RADIOLOGY, 2001, 221 : 243 - 243