Adequacy of haemodialysis with cuffed central-vein catheters

被引:58
|
作者
Atherikul, K [1 ]
Schwab, SJ [1 ]
Conlon, PJ [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Med, Div Nephrol, Durham, NC 27710 USA
关键词
adequacy; catheter; ESRD; haemodialysis; Kt/V; recirculation; renal failure; PermCath;
D O I
10.1093/ndt/13.3.745
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Cuffed central-venous haemodialysis catheters are emerging as an alternative permanent haemodialysis vascular access. There is limited data regarding the adequacy of dialysis with prolonged used of these catheters. We conducted a prospective study comparing three commonly used cuffed central-venous haemodialysis catheters: (1) PermCath(TM), Quinton Instrument Co, Seattle; (2) Tesio(TM), Med Comp, Inc, Harleysville PA; (3) VasCath Soft Cell(TM), Bard Instrument Company, Toronto, and compared them with control patients dialysing with arteriovenous access (AV) prolonged temporary vascular access to placement of one of three catheters. The control group comprised of 222 patients dialysing simultaneously in the same units with AV access. Methods: All patients were dialysed with identical machines and kidneys. Maximal effort were made with every catheter to optimize achievable blood flow. Catheters with mechanical problems were treated first with urokinase and then fibrin sheath catheter stripping. The mean blood flow was determined by averaging mean blood flows from 30 consecutive treatments. Reliability of catheter was defined as percentage of treatments that were performed at a median blood flow of 350 ml/min or above during these 30 treatments. Kt/V was measured monthly and calculated using the single-pool Daugirdas formula. haemodialysis prescription were adjusted for Kt/V above 1.2. Recirculation was measured using two-nedle low-blood-flow technique. Results: The mean blood flows were (PermCath 383.6 ml/min, Tesio 396.3 ml/min, VasCath 320.4 ml/min). PermCath and Tesio had comparable mean blood flows and were significantly higher than VasCath (P<0.005). Reliability of catheters were (PermCath 86.9%, Tesio 81.6%, VasCath 42.3%). Tesio and PermCath were equally reliable and both were more reliable than VasCath (P<0.005). Had the target for reliability been 300 ml/min all three catheters would have been equally reliable. Negative arterial pressure in excess of 300 mmHg prevented faster blood flows in 98% of instances. None of the catheters performed as well as the control population with AV access (mean blood flow 437 ml/min, reliability 96%, P<0.005). Recirculation rates were 3.7% for PermCath, 3.9% for Tesio, and 4% for VasCath. All patients weighing less than 85kg achieved a Kt/V of 1.2 with a 4-h treatment. For comparison purposes when Kt/V was normalized to a 70 kg patient the results were PermCath 1.42, Tesio 1.44, VasCath 1.19, AV access 1.64. Summary: All three catheters are capable of providing adequate haemodialysis although large patients will need extended treatment times. The PermCath(TM) and Tesio(TM) provide blood flow and reliability superior to the VasCath(TM). Blood flow is limited in all catheters by inflow, as evidenced by negative arterial pressure. All catheters had acceptable recirculation. AV access is superior in terms of blood flow and reliability to all tested catheters.
引用
收藏
页码:745 / 749
页数:5
相关论文
共 50 条
  • [41] Intrahospital infection as a risk in haemodialysis patients with central venous catheters
    V Gerasimovska
    K Popovska-Jovanovska
    BMC Proceedings, 5 (Suppl 6)
  • [42] Six cases of retained central venous haemodialysis access catheters
    Hassan, Amir
    Khalifa, Mohammed
    Al-Akraa, Mahmoud
    Lord, Rozanne
    Davenport, Andrew
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (07) : 2005 - 2008
  • [43] POSITIONING CENTRAL VENOUS CATHETERS THROUGH BASILIC VEIN - COMPARISON OF CATHETERS
    NG, WS
    ROSEN, M
    BRITISH JOURNAL OF ANAESTHESIA, 1973, 45 (12) : 1211 - 1214
  • [44] Translumbar central venous catheters for long-term haemodialysis
    Power, Albert
    Singh, Seema
    Ashby, Damien
    Hamady, Mohamed
    Moser, Steve
    Gedroyc, Wady
    Taube, David
    Duncan, Neill
    Cairns, Thomas
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2010, 25 (05) : 1588 - 1595
  • [45] Central venous catheters for haemodialysis: looking for optimal blood flow
    Jean, G
    Chazot, C
    Vanel, T
    Charra, B
    Terrat, JC
    Calemard, E
    Laurent, G
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1997, 12 (08) : 1689 - 1691
  • [46] Tunnelled haemodialysis catheters in central Free State: Epidemiology and complications
    Fox, John
    Joubert, Gina
    Loggenberg, Eugene
    SA JOURNAL OF RADIOLOGY, 2019, 23 (01):
  • [47] Reducing infections associated with central vein catheters
    Canaud, B
    SEMINARS IN DIALYSIS, 2000, 13 (03) : 206 - 207
  • [48] Infections related to central vein dialysis catheters
    Syrganis, Christos
    Argiraki, Elefteria
    Koutroubas, George
    Daitzikis, Konstantinos
    Petridou, Pelagia
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 465 - 465
  • [49] A TECHNIQUE FOR CORRECT POSITIONING OF CENTRAL VEIN CATHETERS
    GUI, D
    INTENSIVE CARE MEDICINE, 1985, 11 (05) : 274 - 275
  • [50] HEMOLYSIS DUE TO CENTRAL VEIN HEMODIALYSIS CATHETERS
    KORZETS, A
    ZEVIN, D
    SEMINARS IN DIALYSIS, 1991, 4 (04) : 286 - 287