Adequacy of haemodialysis with cuffed central-vein catheters

被引:58
|
作者
Atherikul, K [1 ]
Schwab, SJ [1 ]
Conlon, PJ [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Med, Div Nephrol, Durham, NC 27710 USA
关键词
adequacy; catheter; ESRD; haemodialysis; Kt/V; recirculation; renal failure; PermCath;
D O I
10.1093/ndt/13.3.745
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Cuffed central-venous haemodialysis catheters are emerging as an alternative permanent haemodialysis vascular access. There is limited data regarding the adequacy of dialysis with prolonged used of these catheters. We conducted a prospective study comparing three commonly used cuffed central-venous haemodialysis catheters: (1) PermCath(TM), Quinton Instrument Co, Seattle; (2) Tesio(TM), Med Comp, Inc, Harleysville PA; (3) VasCath Soft Cell(TM), Bard Instrument Company, Toronto, and compared them with control patients dialysing with arteriovenous access (AV) prolonged temporary vascular access to placement of one of three catheters. The control group comprised of 222 patients dialysing simultaneously in the same units with AV access. Methods: All patients were dialysed with identical machines and kidneys. Maximal effort were made with every catheter to optimize achievable blood flow. Catheters with mechanical problems were treated first with urokinase and then fibrin sheath catheter stripping. The mean blood flow was determined by averaging mean blood flows from 30 consecutive treatments. Reliability of catheter was defined as percentage of treatments that were performed at a median blood flow of 350 ml/min or above during these 30 treatments. Kt/V was measured monthly and calculated using the single-pool Daugirdas formula. haemodialysis prescription were adjusted for Kt/V above 1.2. Recirculation was measured using two-nedle low-blood-flow technique. Results: The mean blood flows were (PermCath 383.6 ml/min, Tesio 396.3 ml/min, VasCath 320.4 ml/min). PermCath and Tesio had comparable mean blood flows and were significantly higher than VasCath (P<0.005). Reliability of catheters were (PermCath 86.9%, Tesio 81.6%, VasCath 42.3%). Tesio and PermCath were equally reliable and both were more reliable than VasCath (P<0.005). Had the target for reliability been 300 ml/min all three catheters would have been equally reliable. Negative arterial pressure in excess of 300 mmHg prevented faster blood flows in 98% of instances. None of the catheters performed as well as the control population with AV access (mean blood flow 437 ml/min, reliability 96%, P<0.005). Recirculation rates were 3.7% for PermCath, 3.9% for Tesio, and 4% for VasCath. All patients weighing less than 85kg achieved a Kt/V of 1.2 with a 4-h treatment. For comparison purposes when Kt/V was normalized to a 70 kg patient the results were PermCath 1.42, Tesio 1.44, VasCath 1.19, AV access 1.64. Summary: All three catheters are capable of providing adequate haemodialysis although large patients will need extended treatment times. The PermCath(TM) and Tesio(TM) provide blood flow and reliability superior to the VasCath(TM). Blood flow is limited in all catheters by inflow, as evidenced by negative arterial pressure. All catheters had acceptable recirculation. AV access is superior in terms of blood flow and reliability to all tested catheters.
引用
收藏
页码:745 / 749
页数:5
相关论文
共 50 条
  • [1] Cuffed central venous hemodialysis catheters and adequacy of dialysis
    Athirakul, K
    Conlon, P
    Schwab, S
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0785 - A0785
  • [2] 10 YEARS EXPERIENCE IN THE USE OF CUFFED-TUNNELED CENTRAL VASCULAR CATHETERS IN PAEDIATRIC HAEMODIALYSIS
    Morante Martinez, Diego
    Fernandez Camblor, Carlota
    Espinosa Roman, Laura
    Melgosa Hijosa, Marta
    Camarena Pinero, Ascension
    Herretes Balsa, Ana Isabel
    Lopez Font, Miriam
    Alonso Melgar, Angel
    PEDIATRIC NEPHROLOGY, 2023, 38 : S99 - S99
  • [3] DO TUNNELED CUFFED HAEMODIALYSIS CATHETERS JUST FALL OUT?
    Saunders, J.
    Aravindan, A. N.
    Gonzalez, N.
    Howlin, K. J.
    Jefferys, A.
    Makris, A.
    Spicer, S. T.
    Suranyi, M. G.
    Cleland, B. G.
    Wong, J.
    NEPHROLOGY, 2007, 12 : A24 - A25
  • [4] Iliac cuffed tunnelled catheters for chronic haemodialysis vascular access
    Betz, Christoph
    Kraus, Daniel
    Mueller, Cindy
    Geiger, Helmut
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (07) : 2009 - 2012
  • [5] A prospective study of complications associated with cuffed, tunnelled haemodialysis catheters
    Little, MA
    O'Riordan, A
    Lucey, B
    Farrell, M
    Lee, M
    Conlon, PJ
    Walshe, JJ
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (11) : 2194 - 2200
  • [6] FATAL THROMBOEMBOLISM AFTER CENTRAL-VEIN CATHETERIZATION
    MULLER, KM
    BLAESER, B
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1976, 101 (11) : 411 - 413
  • [7] LOWDOSE UROKINASE INFUSION TO RESTORE THE PATENCY OF TUNNELED CENTRAL VEIN HAEMODIALYSIS CATHETERS
    Spanos, Georgios
    Singh, Seema
    Charif, Rawya
    McLean, Adam
    Frankel, Andrew
    Clutterbuck, Elaine
    Ashby, Damien
    Levy, Jeremy
    Duncan, Neill
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [8] Tunnelled (cuffed) haemodialysis catheters: a questionnaire survey of policies and outcomes in the UK
    Kumwenda, MJ
    Wright, FK
    KIDNEY INTERNATIONAL, 1999, 55 (06) : 2595 - 2596
  • [9] TREATMENT WITH TISSUE PLASMINOGEN ACTIVATOR FOR DYSFUNCTIONAL CUFFED TUNNELED HAEMODIALYSIS CATHETERS
    Todorov, Verica
    Jankovic, Aleksandar
    Bulatovic, Ana
    Djuric, Petar
    Mitrovic, Milos
    Maslarevic, Vesna
    Dragovic, Jelena Tosic
    Popovic, Verica Stankovic
    Dimkovic, Nada
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 269 - 269
  • [10] HAEMODIALYSIS BY 2 PERCUTANEOUS CATHETERS IN FEMORAL VEIN
    SERF, B
    TOMASEK, R
    LANCET, 1964, 1 (733): : 476 - &