Introduction: Transfemoral amputation leads to a series of functional changes in the body biomechanics that can interfere with the daily life of the amputee, generating patterns of posture and gait to compensate for the loss of the limb. Objective: This study aims to evaluate and compare the muscular responses of the hip during isometric contractions in transfemoral amputees, using an isokinetic dynamometer. Method: The study included four volunteers, two amputees and two non-amputees. Evaluation was performed using an isokinetic dynamometer in isometric angles of 30 and 60 degrees of 10 seconds duration. Each series was made of six repetitions, composed by three pushups and three extensions with a 20 seconds interval between each sequence. Results: The amputated limb showed a lower peak torque compared to the non-amputee, both in flexion and in extension of the hip at 30 and 60 degrees. Conclusion: Due to amputation, individuals have less hip muscle strength, which may impair daily activities such as walking, sitting and standing, climbing and descending stairs.
引用
收藏
页码:336 / 339
页数:4
相关论文
共 50 条
  • [41] Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking
    Lee, Winson C. C.
    Frossard, Laurent A.
    Hagberg, Kerstin
    Haggstrom, Eva
    Gow, David Lee
    Gray, Steven
    Branemark, Rickard
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (07) : 825 - 833
  • [42] Leg stiffness during sprinting in transfemoral amputees with running specific prosthesis
    Sano, Yoko
    Makimoto, Atsushi
    Hashizume, Satoru
    Murai, Akihiko
    Kobayashi, Yoshiyuki
    Takemura, Hiroshi
    Hobara, Hiroaki
    GAIT & POSTURE, 2017, 56 : 65 - 67
  • [43] MYOELECTRIC ACTIVATION DIFFERENCES IN TRANSFEMORAL AMPUTEES DURING LOCOMOTOR STATE TRANSITIONS
    Nakamura, Bryson H.
    Hahn, Michael E.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2016, 28 (06):
  • [44] Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer
    de Carvalho Froufe Andrade, Alberto Cesar Pereira
    Caserotti, Paolo
    Pereira de Carvalho, Carlos Manuel
    de Azevedo Abade, Eduardo Andre
    da Eira Sampaio, Antonio Jaime
    JOURNAL OF HUMAN KINETICS, 2013, 37 : 47 - 53
  • [45] Effect of different muscle contraction interventions using an isokinetic dynamometer on muscle recovery following muscle injury
    Kang, Min-Suk
    Kim, Jooyoung
    Lee, Joohyung
    JOURNAL OF EXERCISE REHABILITATION, 2018, 14 (06) : 1080 - 1084
  • [46] Reliability of Maximal Voluntary Contraction Related Parameters Measured by a Novel Portable Isometric Knee Dynamometer
    Sarabon, N.
    Rosker, J.
    Fruhmann, H.
    Burggraf, S.
    Loefler, S.
    Kern, H.
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2013, 23 (01) : 22 - 27
  • [47] An examination of mechanomyographic signal stationarity during concentric isokinetic, eccentric isokinetic and isometric muscle actions
    Beck, Travis W.
    DeFreitas, Jason M.
    Stock, Matt S.
    Dillon, Michael A.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (03) : 339 - 361
  • [48] ISOMETRIC HIP ABDUCTOR STRENGTH OF ABOVE-KNEE AMPUTEES AS A FUNCTION OF FEMUR ANGLE
    RYSER, DK
    ERICKSON, RR
    CAHALAN, T
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1986, 67 (09): : 640 - 640
  • [49] TORQUE CURVES PRODUCED AT THE KNEE DURING ISOMETRIC AND ISOKINETIC EXERCISE
    SCUDDER, GN
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1980, 61 (02): : 68 - 73
  • [50] Reliability of a Portable Fixed Dynamometer During Different Isometric Hamstring Assessments
    Woodbridge, Ryan
    Ryan, Chloe
    Burkitt, Josh
    Ye-Lee, Dana
    Cronin, John
    APPLIED SCIENCES-BASEL, 2024, 14 (22):