Wearable technology reveals gait compensations, unstable walking patterns and fatigue in people with multiple sclerosis

被引:34
|
作者
Psarakis, Michael [1 ]
Greene, David A. [1 ]
Cole, Michael H. [1 ]
Lord, Stephen R. [2 ]
Phu Hoang [1 ,2 ]
Brodie, Matthew [2 ,3 ]
机构
[1] Australian Catholic Univ, Fac Hlth Sci, Sydney, NSW, Australia
[2] Univ New South Wales, Neurosci Res Australia, Sydney, NSW, Australia
[3] UNSW, Grad Sch Biomed Engn, Sydney, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
harmonic ratio; accelerometer; dynamic stability; compensations; gait screening; PASSIVE MECHANICAL-PROPERTIES; PARKINSONS-DISEASE; OLDER-PEOPLE; ACCELERATION PATTERNS; CEREBRAL-PALSY; HEAD; PELVIS; GASTROCNEMIUS; OSCILLATIONS; INDIVIDUALS;
D O I
10.1088/1361-6579/aac0a3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: People with multiple sclerosis (PwMS) often experience a dedine in gait performance, which can compromise their independence and increase falls. Ankle joint contractures in PWMS are common and often result in compensatory gait patterns to accommodate reduced ankle range of motion (ROM). Approach: Using advances in wearable technology, the aim of this study was to quantify head and pelvis movement patterns that occur in PwMS with disability and determine how these secondary gait compensations impact on gait stability. Twelve healthy participants and 12 PwMS participated in the study. Head and pelvis movements were measured using two tri-axial accelerometers. Measures of gait compensation, mobility, variability, asymmetry, stability and fatigue were assessed during a 6 min walking test. Main results: Compared to healthy controls, PwMS had greater vertical asymmetry in their head and pelvic movements (Cohen's d = 1.85 and 1.60). Lower harmonic ratios indicated that PwMS were more unstable than controls (Cohen's d = -1.61 to -3.06), even after adjusting for their slower walking speeds. In the PWMS, increased compensatory movements were correlated with reduced ankle active ROM (r = -0.71), higher disability (EDSS) scores (r = 0.58), unstable gait (r = -0.76), reduced mobility (r = -0.76) and increased variability (r = 0.83). Significance: Wearable device technology provides an efficient and reliable way to screen for excessive compensatory movements often present in PWMS and provides clinically important information that impacts on mobility, stride time variability and gait stability. This information may help clinicians identify PWMS at high risk of falling and develop better rehabilitation interventions that, in addition to improving mobility, may help target the underlying causes of unstable gait.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Fatigue in Japanese people with multiple sclerosis
    Moriya, Rika
    Kutsumi, Masami
    NURSING & HEALTH SCIENCES, 2010, 12 (04) : 421 - 428
  • [32] Depression and fatigue in people with multiple sclerosis
    Bando, Mauricio
    Canzonieri, Ana Maria
    Dias, Alice
    Telles, Juliana
    Silva, Talita
    Massa, Marcelo
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (02) : NP24 - NP24
  • [33] Validation of an Instrumented Shoe Insole to Unobtrusively Monitor Gait Patterns of People with Multiple Sclerosis
    Mavor, Matthew
    Mir-Orefice, Alexandre
    Graham, Ryan
    MULTIPLE SCLEROSIS JOURNAL, 2023, 29 : 913 - 913
  • [34] Risk of falling in walking people with multiple sclerosis
    Gonzalez, FA
    Kwiatkowski, E
    Caceres, E
    Gold, L
    MULTIPLE SCLEROSIS, 2005, 11 : S96 - S96
  • [35] Mobile Technology Use by People Experiencing Multiple Sclerosis Fatigue: Survey Methodology
    Van Kessel, Kirsten
    Babbage, Duncan R.
    Reay, Nicholas
    Miner-Williams, Warren M.
    Kersten, Paula
    JMIR MHEALTH AND UHEALTH, 2017, 5 (02):
  • [36] Monitoring gait in multiple sclerosis with novel wearable motion sensors
    Moon, Yaejin
    McGinnis, Ryan S.
    Seagers, Kirsten
    Motl, Robert W.
    Sheth, Nirav
    Wright, John A., Jr.
    Ghaffari, Roozbeh
    Sosnoff, Jacob J.
    PLOS ONE, 2017, 12 (02):
  • [37] Gait Analysis using Wearable Sensors with Multiple Sclerosis Patients
    Jurisic Skevin, Aleksandra
    Filipovic, Nenad
    Mijailovic, Nikola
    Divjak, Ana
    Nurkovic, Jasmin
    Radakovic, Radivoje
    Gacic, Marija
    Grbovic, Vesna
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2018, 25 : 339 - 342
  • [38] Gait and heart rate: do they measure trait or state physical fatigue in people with multiple sclerosis?
    Galperin, Irina
    Buzaglo, David
    Gazit, Eran
    Shimoni, Nathaniel
    Tamir, Raz
    Regev, Keren
    Karni, Arnon
    Hausdorff, Jeffrey M.
    JOURNAL OF NEUROLOGY, 2024, 271 (07) : 4462 - 4472
  • [39] Manifestations of walking fatigability in people with multiple sclerosis based on gait quality and distance walked during the six minutes walking test
    Santinelli, Felipe Balistieri
    Abasiyanik, Zuhal
    Ramari, Cintia
    Gysemberg, Griet
    Kos, Daphne
    Pau, Massimiliano
    Kalron, Alon
    Meyns, Pieter
    Ozakbas, Serkan
    Feys, Peter
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2024, 91
  • [40] The effect of rhythmic cued motor imagery on walking, fatigue and quality of life in people with multiple sclerosis
    Seebacher, B.
    Kuisma, R.
    Glynn, A.
    Berger, T.
    MULTIPLE SCLEROSIS JOURNAL, 2015, 21 : 48 - 48