Ticlopidine-induced neutropenia mimicking sepsis early after intracoronary stent placement

被引:2
|
作者
Ochoa, AB
Wolfe, M
Lewis, P
Lenihan, DJ [1 ]
机构
[1] Wright Patterson Med Ctr, Div Cardiol, SGOMC, Wright Patterson AFB, OH 45433 USA
[2] Wright Patterson Med Ctr, Dept Internal Med, Wright Patterson AFB, OH 45433 USA
关键词
ticlopidine; sepsis; neutropenia; intracoronary stent;
D O I
10.1002/clc.4960210417
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report a case of ticlopidine-induced profound neutropenia early in the course of therapy, which was manifest as a febrile systemic illness mimicking sepsis. This clinical presentation was potentially indicative of a contaminated intracoronary stent. The patient's signs and symptoms of illness promptly resolved with removal of ticlopidine, and no infection was documented. Review of indications for ticlopidine use, potential adverse effects, and monitoring recommendations are discussed.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 50 条
  • [31] A randomized comparison of cilostazol versus ticlopidine therapy after elective coronary stent placement.
    Park, SW
    Lee, HJ
    Park, HK
    Lee, CW
    Hong, MK
    Kim, JJ
    Park, SJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (7A): : 97S - 97S
  • [32] EARLY DYSPHAGIA AFTER PLACEMENT OF A SELF-EXPANDING ESOPHAGEAL STENT - SEVERE ESOPHAGITIS MIMICKING LUMINAL OCCLUSION
    WISHINGRAD, M
    KIM, M
    TRIADAFILOPOULOS, G
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1995, 90 (09): : 1525 - 1526
  • [33] Frequency and outcome of development of coronary artery aneurysm after intracoronary stent placement and angioplasty
    Slota, PA
    Fischman, DL
    Savage, MP
    Rake, R
    Goldberg, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (08): : 1104 - &
  • [34] Frequency of adverse clinical events in the 12 months following successful intracoronary stent placement in patients treated with aspirin and ticlopidine (without warfarin)
    Berger, PB
    Bell, MR
    Grill, DE
    Melby, S
    Holmes, DR
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (06): : 713 - 718
  • [35] Ticlopidine without coumadin is enough for the prevention of stent thrombosis after elective intracoronary Palmaz-Schatz stent implantation results of NoPAIN trial
    Saito, S
    Nobuyoshi, M
    Oohata, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 92720 - 92720
  • [36] VERY EARLY IN-STENT RESTENOSIS AFTER A BARE METAL STENT PLACEMENT
    Tyagi, Gaurav
    Minnelli, Carrie
    Azarbaijani, Ramin Assadi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A684 - A684
  • [37] Does the timing of myocardial perfusion imaging after intracoronary stent placement impact on the detection of restenosis?
    Poornima, IG
    Hodge, DO
    Miller, TD
    Gibbons, RJ
    Christian, TF
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 402A - 402A
  • [38] Lipoprotein(a), apolipoprotein(a) polymorphism and restenosis after intracoronary stent placement in Type 2 diabetic patients
    Gazzaruso, C
    Garzaniti, A
    Falcone, C
    Puija, A
    Geroldi, D
    Giordanetti, S
    Fratino, P
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2003, 17 (03) : 135 - 140
  • [39] Platelet and leukocyte deactivation after intracoronary stent placement in patients receiving combined antiplatelet therapy
    Atalar, E
    Aytemir, K
    Haznedaroglu, I
    Aksöyek, S
    Övünç, K
    Kirazli, S
    Özmen, F
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2001, 7 (02) : 116 - 121
  • [40] ALTERATIONS OF CORONARY FLOW VELOCITY DISTAL TO CORONARY DISSECTIONS BEFORE AND AFTER INTRACORONARY STENT PLACEMENT
    KERN, MJ
    AGUIRRE, FV
    BACH, RG
    CARACCIOLO, EA
    DONOHUE, TJ
    FLYNN, MS
    MOORE, JA
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 31 (04): : 309 - 315