Cadmium ion-selective sorbent preconcentration method using ion imprinted poly(ethylene glycol dimethacrylate-co-vinylimidazole)

被引:87
|
作者
Segatelli, Mariana Gava [1 ]
Santos, Vivian Silva [1 ]
Teixeira Presotto, Amanda Braga [1 ]
Pagotto Yoshida, Inez Valeria
Teixeira Tarley, Cesar Ricardo [1 ,2 ]
机构
[1] Univ Fed Alfenas UNIFAL MG, Dept Ciencias Exatas, BR-37130000 Alfenas, MG, Brazil
[2] Univ Estadual Campinas UNICAMP, Inst Nacl Ciencia & Tecnol Bioanalit, Inst Quim, Dept Quim Analit, BR-13083970 Campinas, SP, Brazil
来源
REACTIVE & FUNCTIONAL POLYMERS | 2010年 / 70卷 / 06期
关键词
Cadmium; Ion imprinted polymer; Sorbent preconcentration; SOLID-PHASE EXTRACTION; INORGANIC HYBRID SORBENT; AQUEOUS-SOLUTION; ONLINE PRECONCENTRATION; ANALYTICAL-CHEMISTRY; DOEHLERT MATRIX; POLYMERS; SEPARATION; OPTIMIZATION; RECOGNITION;
D O I
10.1016/j.reactfunctpolym.2010.02.006
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The present study focuses on the preparation of an Cd2+-imprinted poly(ethylene glycol dimethacrylate-co-vinylimidazole) for selective extraction/preconcentration of Cd2+ ions from aqueous solution, with further determination by FAAS using a flow system Sorbent extraction/preconcentration system was optimized by using chemometric tools (factorial design and Doehlert matrix). Under optimized conditions, the method presented a limit of detection of 0.11 mu g L-1 and linear analytical curve from 1.0 up to 50 0 mu g L-1 (r = 0.993). The preconcentration factor (PF), consumptive index (CI) and concentration efficiency (CE) were found to be 38.4, 0.39 mL and 14 3 min(-1), respectively. The selectivity coefficient of ion imprinted polymer was compared with the selectivity coefficient of NIP (non-imprinted polymer) for the Cd2+/Pb2+, Cd2+/Cu2+ and Cd2+/Zn2+ binary mixtures, where the respective values of relative selectivity coefficient (k') of 1575, 4.44 and 1.38 were obtained. The proposed method was successfully applied for cadmium determination in different types of water samples, urine and certified reference material (Lobster Hepatopancreas). Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved
引用
收藏
页码:325 / 333
页数:9
相关论文
共 50 条
  • [21] Investigation of chromium preconcentration conditions by solid phase extraction method using activated carbon based ion-imprinted sorbent
    Canlidinc, Rukiye Saygili
    Turan, Kubra
    Kalfa, Orhan Murat
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 104 (17) : 5316 - 5336
  • [22] Ion-Selective Organic Electrochemical Transistor Sensors Using Molecularly Imprinted Polymers
    Woeppel, Aaron B.
    Schaefer, Janessa
    Kim, Ho Joong
    Boudouris, Bryan W.
    Beaudoin, Stephen P.
    ACS APPLIED POLYMER MATERIALS, 2022, 4 (09) : 6667 - 6674
  • [23] Determination of trace amounts of Co(II) after preconcentration with surface ion imprinted sorbent based on activated carbon
    Turan, Kubra
    Canlidinc, Rukiye Saygili
    Kalfa, Orhan Murat
    SEPARATION SCIENCE AND TECHNOLOGY, 2018, 53 (05) : 707 - 716
  • [24] Insight into the morphology, pore structure and sorption properties of 4-hydroxy-3-nitrophenylacetic acid imprinted poly(acrylic acid-co-ethylene glycol dimethacrylate) sorbent
    Janczura, Marta
    Sobiech, Monika
    Lulinski, Piotr
    POLYMER TESTING, 2021, 93
  • [25] ALKALI AND ALKALINE-EARTH METAL-ION ADDUCTS OF POLY(PROPYLENE GLYCOL) AS SENSORS FOR ION-SELECTIVE ELECTRODES
    JABER, AMY
    MOODY, GJ
    THOMAS, JDR
    ANALYST, 1977, 102 (1221) : 943 - 948
  • [26] Influence of solvents on chiral discriminative gate effect of molecularly imprinted poly(ethylene glycol dimethacrylate-co-methacrylic acid)
    Sekine, Shinichi
    Watanabe, Yuta
    Yoshimi, Yasuo
    Hattori, Koji
    Sakai, Kiyotaka
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (02) : 512 - 517
  • [27] Improved Ion-Selective Detection Method Using Nanopipette with Poly(vinyl chloride)-Based Membrane
    Kang, Eun Ji
    Takami, Tomohide
    Deng, Xiao Long
    Son, Jong Wan
    Kawai, Tomoji
    Park, Bae Ho
    JOURNAL OF PHYSICAL CHEMISTRY B, 2014, 118 (19): : 5130 - 5134
  • [28] Using of hydrogen ion-selective poly(vinyl chloride) membrane electrode based on calix[4]arene as thiocyanate ion-selective electrode
    Erden, S
    Demirel, A
    Memon, S
    Yilmaz, M
    Canel, E
    Kiliç, E
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) : 290 - 296
  • [29] A numerical study of sample preconcentration using ion concentration polarization in single microfluidic channels with dual ion-selective membranes
    Van-Truong Dang
    Van-Sang Pham
    AIP ADVANCES, 2023, 13 (09)
  • [30] Development of a Dysprosium (III) Ion-selective Electrode Using a Dysprosium (III)-imprinted Polymer
    Fujiwara, Isamu
    Takeuchi, Kenjiro
    Murakami, Yoshiko
    BUNSEKI KAGAKU, 2016, 65 (09) : 527 - 531