HOW MUCH DO I GIVE? REEVALUATION OF INSULIN DOSING ESTIMATION FORMULAS USING CONTINUOUS GLUCOSE MONITORING

被引:17
|
作者
King, Allen B. [1 ]
机构
[1] Diabet Care Ctr, Salinas, CA USA
关键词
D O I
10.4158/EP09308.OR
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To reevaluate current formulas for determining the total basal insulin dosage (TBD), insulin to carbohydrate ratio (ICR), and correction factor (CF) from weight or total daily dosage (TDD) in pump-treated patients with type 1 diabetes mellitus. Methods: From a post hoc analysis of data from 4 previously published studies, subjects who met the inclusion criteria were selected. No subject was duplicated. For all studies, the basal glucose target was to have fewer than 20% of glucose readings greater than 170 mg/dL and to have 10% or fewer glucose readings less than 70 mg/dL. Bolus insulin was adjusted to achieve a 2- to 4-hour postbolus glucose value within 20% of the premeal glucose (ICR) or 80 to 120 mg/dL from premeal hyperglycemia (CF). In the first 2 studies, dosing titration by CGM was performed from 72-hour CGM tracings every week to every 6 weeks. In the other 2 studies, 24- to 72-hour CGM downloads and insulin adjustments were done each weekday. Results: Of 101 participants, 61 (59% women) met the inclusion criteria. Estimation formulas could be rounded to the following: TBD = 0.2 x weight (kg) or 0.4 x TDD; ICR = 300 divided by TDD; and CF = 1500 divided by TDD. In particular the relationship between all 3 dosing factors could be represented as 100 divided by TBD = ICR = CF divided by 4.5. Conclusions: These results suggest that current formulas give a higher estimate for TBD and a lower estimate for the bolus dose. (Endocr Pract. 2010;16:428-432)
引用
收藏
页码:428 / 432
页数:5
相关论文
共 50 条
  • [31] Glycemic Impact of Meal-Dosing Behavior in Users of the InPen Smart Insulin Pen (SIP) Paired with Continuous Glucose Monitoring (CGM)
    Macleod, Janice
    Smith, Madison
    Im, Glen Heungyong
    Cordero, Toni L.
    Vigersky, Robert A.
    DIABETES, 2023, 72
  • [32] Evaluation of the quality of basal insulin replacement with insulin glargine in type 1 diabetes using continuous glucose monitoring system
    Howorka, K
    Pumprla, J
    Gabriel, M
    Grillmayr, H
    Schabmann, A
    DIABETES, 2002, 51 : A123 - A123
  • [33] A qualitative comparison between multiple daily injections and continuous subcutaneous insulin infusion using a continuous glucose monitoring system
    Javor, ED
    Ilic, S
    Lee, SW
    DIABETES, 2001, 50 : A438 - A438
  • [34] A clinical study of meal size estimation analysis using continuous glucose monitoring (CGM) data
    Lee, Hyunjin
    Caswell, Kimberly
    Dassau, Eyal
    Doyle, Francis J., III
    Buckingham, Bruce A.
    Bequette, B. W.
    DIABETES, 2008, 57 : A545 - A545
  • [35] Advancing Telemedicine Using Smart Insulin Pens with Continuous Glucose Monitoring and Telecommunication Systems: A Case Series
    Singh, Lakshmi G.
    Gothong, Chikara
    Ash, Garrett I.
    Hernandez, Reynier
    Spanakis, Elias K.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [36] BENEFITS OF THREE-MONTH CONTINUOUS GLUCOSE MONITORING FOR PERSONS WITH DIABETES USING INSULIN PUMPS AND SENSORS
    Peterson, Karolina
    Zapletalova, Jana
    Kudlova, Pavla
    Matuskova, Veronika
    Bartek, Josef
    Novotny, Dalibor
    Chlup, Rudolf
    BIOMEDICAL PAPERS-OLOMOUC, 2009, 153 (01): : 47 - 51
  • [37] Responses to Continuous Glucose Monitoring in Subjects with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections
    Rodbard, David
    Jovanovic, Lois
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (12) : 757 - 765
  • [38] A Modified Combination Wave Versus a Square Wave Insulin Bolus Compared Using Continuous Glucose Monitoring in Pump and Pramlintide Treated Type I Diabetes
    King, Allen B.
    Genta, Francine
    Wolfe, Gary S.
    DIABETES, 2009, 58 : A120 - A120
  • [39] Simulating the glycaemic impact of meal insulin dose determinations using continuous glucose monitoring vs self-monitored blood glucose
    Price, D.
    Nandagopalan, S.
    DIABETOLOGIA, 2014, 57 : S390 - S391
  • [40] Two-way crossover comparison of insulin glargine and insulin detemir in basal-bolus therapy using continuous glucose monitoring
    Abe, Shinya
    Inoue, Gaku
    Yamada, Satoru
    Irie, Junichiro
    Nojima, Hiroyuki
    Tsuyusaki, Kaoru
    Usui, Kensuke
    Atsuda, Koichiro
    Yamanouchi, Toshikazu
    DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2011, 4 : 283 - 288