Effect of Interfacial Pressure on Electrical Tree between XLPE and Silicone Rubber

被引:0
|
作者
Su, Yu [1 ]
Liu, Ying [1 ]
Xie, Dongri [1 ]
Zhong, Lisheng [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Shaanxi, Peoples R China
关键词
XLPE cable accessory; silicone rubber; interfacial pressure; electrical tree; INSULATION; FAILURE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
XLPE and silicone rubber (SIR) have been widely used in power cables and accessories for their excellent mechanical and electrical performance. However, the interface between them in accessories remains one of the weakest parts in the cable system. Electrical treeing is an important destructive factor for HV insulation structures, and it always leads to final breakdown. Therefore, it is essential to investigate the effects of interfacial pressure on electrical tree. In this paper, tests were carried out by pressing XLPE and SIR samples together under different interfacial pressures with a specific pressing device. AC voltage was applied on a pair of pin-plane electrodes placed at the interface. The pin-plane distance was 2 mm. The needle diameter was 0.25 mm and the tip curvature radius was (10 +/- 1) mu m. Under different interfacial pressures, the voltages for electrical trees to initiate were recorded and statistically analyzed. Meanwhile, the tree morphology and breakdown channel were also captured by using a digital micro-imaging system. The results show that at a low interfacial pressure of 50 kPa, no electrical trees can be observed. Instead, discharge light can be seen at the interface. As the interfacial pressure increases, electrical tree begins to appear. It is found that at 75 kPa, electrical tree initiates and grows, which finally leads to a severe breakdown along the interface. While at pressures above 100 kPa, electrical tree tends to grow into SIR side, and the breakdown channel is slender, only observed in the SIR. Besides, the electrical tree initiation voltage increases with the increase of the interfacial pressure. It indicates that a high interfacial pressure can effectively delay the initiation of electrical trees, and for the two materials that constitute the interface, XLPE seems to have a better electrical treeing endurance than the SIR.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Influence of Absorbed Gas in Silicone Rubber on Electrical Tree Initiation
    Kamiya, Y.
    Muramoto, Y.
    Shimizu, N.
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 134 - 137
  • [22] Electrical Tree Initiation of Silicone Rubber after Thermal Aging
    Zhou, Yuanxiang
    Zhang, Yunxiao
    Zhang, Ling
    Guo, Dawei
    Zhang, Xu
    Wang, Mingyuan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (02) : 748 - 756
  • [23] The relationship between electrical characteristics and electrical tree degradation in XLPE insulation
    Kang, DS
    Sun, JH
    Lee, HS
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 546 - 549
  • [24] Effect of Voltage Stabilizer on Electrical Tree Properties of XLPE
    Chen X.
    Zhang M.
    Meng F.
    Hong Z.
    Shi Y.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (06): : 2159 - 2167
  • [25] Effect of liquid impregnation on electrical tree initiation in XLPE
    Shimizu, N
    Tanaka, H
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (02) : 239 - 243
  • [26] Electrical tree at high temperature in XLPE and effect of oxygen
    Shimizu, N
    Shibata, Y
    Ito, K
    Imai, K
    Nawata, M
    2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 329 - 332
  • [27] The Effect of Mechanical Strain on Electrical Tree Development in XLPE
    Hu, Frances
    Emersic, Christopher
    Smith, Dominic
    Chen, Lujia
    Rowland, Simon
    Cunningham, Lee
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (01) : 313 - 321
  • [28] Effect of liquid impregnation on electrical tree initiation in XLPE
    Shimizu, N
    Izumitani, M
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 301 - 304
  • [29] Effect of Degassing Time on Initiation of Electrical Tree in XLPE
    He, J. X.
    Fang, J.
    Yang, F.
    Zhang, M.
    2022 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP 2022), 2022, : 353 - 355
  • [30] Effect of Pressure on AC Leakage Current at Interface Between XLPE-Silicon and Rubber
    Gu, L.
    Wang, Y. C.
    Jiang, X.
    Chen, X. G.
    Lei, S. L.
    INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION (ICECA 2014), 2014, : 854 - 859