Limulus Amebocyte Lysate Assay for Endotoxins by an Adsorption Method with Polycation-immobilized Cellulose Beads

被引:13
|
作者
Sakata, Masayo [1 ]
Inoue, Tomofumi [1 ]
Todokoro, Masami [2 ]
Kunitake, Masashi [1 ]
机构
[1] Kumamoto Univ, Grad Sch Sci & Technol, Dept Appl Chem & Biochem, Kumamoto 8608555, Japan
[2] Chisso Co Ltd, Chiyoda Ku, Tokyo 1008105, Japan
关键词
AFFINITY-CHROMATOGRAPHY; CHROMOGENIC SUBSTRATE; PROTEIN SOLUTIONS; REMOVAL; HISTIDINE; PARTICLES;
D O I
10.2116/analsci.26.291
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To assay lipopolysaccharides (LPSs) in solutions containing Limulus amebocyte lysate (LAL)-inhibiting or LAL-enhancing compounds, we developed a selective endotoxin (LPS) assay using poly(E-lysine)-immobilized cellulose beads (PL-Cellufine) and LAL. The PL-Cellufine can adsorb LPSs in a solution containing certain compounds (NaCl, proteins and amino acids) at an ionic strength of mu = 0.05 - 0.4 at neutral pH. The LPSs adsorbed on the PL-Cellufine were separated from the compounds by centrifugation and then the PL-Cellufine was suspended in LPS-free water. The LPS activities of the suspension are directly assayed by a turbidimetric time assay with the LAL reagent. The accuracy of the adsorption method was high compared with those of common solution methods. As for the common method, the apparent recovery of LPS from the compounds was 40 - 95%. This suggests that these compounds inhibit the LAL procedure. By contrast, the adsorption method showed good LPS recovery (88 - 120%) in all cases, without being inhibited or enhanced by the compounds.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 50 条
  • [31] Limulus amebocyte lysate assay for detection of endotoxin in patients with sepsis syndrome
    Bates, DW
    Parsonnet, J
    Ketchum, PA
    Miller, EB
    Novitsky, TJ
    Sands, K
    Hibberd, PL
    Graman, PS
    Lanken, PN
    Schwartz, JS
    Kahn, K
    Snydman, DR
    Moore, R
    Black, E
    Platt, R
    CLINICAL INFECTIOUS DISEASES, 1998, 27 (03) : 582 - 591
  • [32] AUTOMATION OF CHROMOGENIC SUBSTRATE LIMULUS AMEBOCYTE LYSATE ASSAY-METHOD FOR ENDOTOXIN BY ROBOTIC SYSTEM
    TSUJI, K
    MARTIN, PA
    BUSSEY, DM
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (03) : 550 - 555
  • [33] ASSAY OF BACTERIAL-ENDOTOXIN IN HEMOGLOBIN SAMPLES BY A KINETIC TURBIDIMETRIC LIMULUS AMEBOCYTE LYSATE METHOD
    MCGOWN, EL
    WOOD, FE
    FASEB JOURNAL, 1992, 6 (04): : A1339 - A1339
  • [34] DETECTION OF PLASMA ENDOTOXIN WITH A LIMULUS AMEBOCYTE LYSATE (LAL)-CHROMOGENIC SUBSTRATE ASSAY
    STEMBERGER, A
    STRASSER, F
    VONHUNDELSHAUSEN, B
    TEMPEL, G
    BLUMEL, G
    ACTA CHIRURGICA SCANDINAVICA, 1982, : 49 - 53
  • [35] METHODOLOGICAL ASPECTS OF THE ENDOTOXIN DETERMINATION WITH THE LIMULUS AMEBOCYTE LYSATE CHROMOGENIC SUBSTRATE ASSAY
    STEMBERGER, A
    STRASSER, F
    VONHUNDELSHAUSEN, B
    BLUMEL, G
    THROMBOSIS AND HAEMOSTASIS, 1983, 50 (01) : 467 - 467
  • [36] RAPID DETECTION OF SIGNIFICANT BACTERIURIA BY USE OF AN AUTOMATED LIMULUS AMEBOCYTE LYSATE ASSAY
    JORGENSEN, JH
    ALEXANDER, GA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1982, 16 (03) : 587 - 589
  • [37] Interference of silica nanoparticles with the traditional Limulus amebocyte lysate gel clot assay
    Kucki, Melanie
    Cavelius, Christian
    Kraegeloh, Annette
    INNATE IMMUNITY, 2014, 20 (03) : 327 - 336
  • [38] RAPID DETECTION OF GRAM-NEGATIVE BACTERIURIA BY LIMULUS AMEBOCYTE LYSATE ASSAY
    NACHUM, R
    SHANBROM, E
    JOURNAL OF CLINICAL MICROBIOLOGY, 1981, 13 (01) : 158 - 162
  • [39] LIMULUS AMEBOCYTE LYSATE TEST FOR ENDOTOXEMIA - INVESTIGATIONS WITH A FEMOTOGRAM SENSITIVE SPECTROPHOTOMETRIC ASSAY
    FINK, PC
    LEHR, L
    URBASCHEK, RM
    KOZAK, J
    KLINISCHE WOCHENSCHRIFT, 1981, 59 (05): : 213 - 218
  • [40] APPLICATIONS OF THE LIMULUS AMEBOCYTE LYSATE ASSAY TO TESTING OF HUMAN-SERUM ALBUMIN
    PEARSON, FC
    BACICH, J
    SRIGLEY, W
    MAGLALANG, E
    GRAFF, E
    ABROSON, F
    GARCIA, D
    DEVELOPMENTS IN INDUSTRIAL MICROBIOLOGY, 1981, 22 : 371 - 380