Zero Energy Building Economic and Energetic Assessment with Simulated and Real Data Using Photovoltaics and Water Flow Glazing

被引:4
|
作者
Gonzalo, Fernando del Ama [1 ]
Moreno Santamaria, Belen [2 ]
Gea, Jose Antonio Ferrandiz [3 ]
Griffin, Matthew [1 ]
Hernandez Ramos, Juan A. [4 ]
机构
[1] Keene State Coll, Sch Sci Sustainabil & Hlth, Dept Sustainable Prod Design & Architecture, 229 Main St, Keene, NH 03435 USA
[2] Tech Univ Madrid UPM, Tech Sch Architecture Madrid, Dept Construct & Architectural Technol, Av Juan de Herrera 4, Madrid 28040, Spain
[3] Norfolk State Univ, Dept Technol, 700 Pk Ave, Norfolk, VA 23504 USA
[4] Tech Univ Madrid UPM, Sch Aeronaut & Space Engn, Escuela Dept Appl Math, Plaza Cardenal Cisneros 3, Madrid 28040, Spain
关键词
water flow glazing; building integrated PV panels; levelized cost of energy; NET-ZERO; THERMAL PERFORMANCE; SELF-CONSUMPTION; BIPV SYSTEM; COST; GLASS; INSTALLATION; ELECTRICITY; DEPENDENCE; ENVELOPE;
D O I
10.3390/en14113272
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The new paradigm of Net Zero Energy buildings is a challenge for architects and engineers, especially in buildings with large glazing areas. Water Flow Glazing (WFG) is a dynamic facade technology shown to reduce heating and cooling loads for buildings significantly. Photovoltaic panels placed on building roofs can generate enough electricity from solar energy without generating greenhouse gases in operation or taking up other building footprints. This paper investigates the techno-economic viability of a grid-connected solar photovoltaic system combined with water flow glazing. An accurate assessment of the economic and energetic feasibility is carried out through simulation software and on-site tests on an actual prototype. The assessment also includes the analysis of global warming potential reduction. A prototype with WFG envelope has been tested. The WFG prototype actual data reported primary energy savings of 62% and 60% CO2 equivalent emission reduction when comparing WFG to a reference triple glazing. Finally, an economic report of the Photovoltaic array showed the Yield Factor and the Levelized Cost of Energy of the system. Savings over the operating lifetime can compensate for the high initial investment that these two technologies require.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Advanced hybrid assessment of glazing systems: A comparative analysis using differential and global methods for precise thermal optimization and energy efficiency in building
    Salazar, Samanta Lopez
    Yang, Ruitong
    Li, Dong
    Chagolla-Aranda, M. A.
    Chavez-Chena, Y.
    Sima, E.
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [22] Energy Consumption Analysis Using Measured Data from a Net-Zero Energy Commercial Building in a Cold and Dry Climate
    Oh, Sukjoon
    Gardner, John F.
    SUSTAINABILITY, 2022, 14 (16)
  • [23] Indoor environmental quality and energy consumption real-time assessment: A field measurement of a nearly zero-energy building in cold region of China
    Liu, Zhijian
    Zhou, Qingxu
    Yin, Hang
    Xu, Wei
    Yang, Xinyan
    Gao, Jun
    ENERGY AND BUILDINGS, 2021, 246
  • [24] Energy-water nexus strategies for the energetic valorization of orange peels based on techno-economic and environmental impact assessment
    Martinez-Hernandez, Elias
    Magdaleno Molina, Moises
    Melgarejo Flores, Luis A.
    Palmerin Ruiz, Ma Esther
    Zermeno EguiaLis, Juan A.
    Rosas Molina, Andres
    Aburto, Jorge
    Amezcua-Allieri, Myriam A.
    FOOD AND BIOPRODUCTS PROCESSING, 2019, 117 : 380 - 387
  • [25] Kinematic orbit determination of LEOs based on zero or double-difference algorithms using simulated and real SST GPS data
    Svehla, D
    Rothacher, M
    VISTAS FOR GEODESY IN THE NEW MILLENNIUM, 2002, 125 : 322 - 328
  • [26] Automated water content reconstruction of zero-offset borehole ground penetrating radar data using simulated annealing
    Rucker, DF
    Ferré, TPA
    JOURNAL OF HYDROLOGY, 2005, 309 (1-4) : 1 - 16
  • [27] Energy, exergy, economic and environmental (4E) analysis using a renewable multi-generation system in a near-zero energy building with hot water and hydrogen storage systems
    Nikitin, Andrey
    Deymi-Dashtebayaz, Mahdi
    Baranov, Igor, V
    Sami, Sourena
    Nikitina, Veronika
    Abadi, Majid Kheir
    Rumiantceva, Olga
    JOURNAL OF ENERGY STORAGE, 2023, 62
  • [28] Building energy performance assessment using linked data and cross-domain semantic reasoning
    Hu, Shushan
    Wang, Jiale
    Hoare, Cathal
    Li, Yehong
    Pauwels, Pieter
    O'Donnell, James
    AUTOMATION IN CONSTRUCTION, 2021, 124
  • [29] Parameter estimation and assessment of bias in genetic evaluation of carcass traits in Hanwoo cattle using real and simulated data
    Bedhane, Mohammed
    van der Werf, Julius
    de las Heras-Saldana, Sara
    Ackerson, Leland
    Lim, Dajeong
    Park, Byoungho
    Park, Mi Na
    Roh, Seunghee
    Clark, Samuel
    JOURNAL OF ANIMAL SCIENCE AND TECHNOLOGY, 2023, 65 (06) : 1180 - 1193
  • [30] Performance analysis of upgraded university building of FERIT Osijek microgrid achieving nearly zero energy standard based on real measurement data
    Margus, Heidi
    Znidarec, Matej
    Sljivac, Damir
    Stojkov, Marinko
    2019 2ND INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES (SEST 2019), 2019,