Flow in coronary bypass conduits on-pump and off-pump

被引:18
|
作者
Kjaergard, HK [1 ]
Irmukhamedov, A [1 ]
Christensen, JB [1 ]
Schmidt, TA [1 ]
机构
[1] Univ Copenhagen, Gentofte Hosp, Dept Cardiothorac Surg, DK-2900 Hellerup, Denmark
来源
ANNALS OF THORACIC SURGERY | 2004年 / 78卷 / 06期
关键词
D O I
10.1016/j.athoracsur.2004.06.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of the study was to measure the blood flow in coronary artery bypass grafting conduits on-pump and off-pump and to estimate the total conduit flow. Methods. In a 3.5-year period, 120 patients having coronary artery bypass grafting on-pump and 97 patients having coronary artery bypass grafting off-pump with the left internal mammary artery anastomosed to the left anterior descending artery and saphenous vein grafts to the remaining diseased coronary arteries were included in the study. Flow in the bypass conduits was measured with the transit-time method. Results. In men the left internal mammary artery flow (mean +/- standard error of the mean) was 33.7 +/- 2.0 mL/min on-pump and 34.4 +/- 2.9 off-pump (p > 0.05). In women the left internal mammary artery flow was 29.4 +/- 3.0 mL/min on-pump and 22.8 +/- 1.9 mL/min off-pump (p > 0.05). In men the vein graft flow per anastomosis was 30.4 +/- 1.3 mL/min on-pump and 37.8 +/- 5.4 mL/min off-pump (p > 0.05). In women the vein graft flow per anastomosis was 28.0 +/- 2.9 mL/min on-pump and 23.2 +/- 2.9 mL/min off-pump (p > 0.05). Consistently in women, the mean conduit flows were numerically lower than in men. In patients undergoing coronary artery bypass grafting on-pump the total conduit flows (left internal mammary artery plus vein grafts) were 131.4 +/- 2.5 mL/min in men and 108.4 +/- 3.2 mL/min in women. Conclusions. There were no major differences in conduit flow on-pump versus off-pump. Conventional coronary artery bypass grafting on-pump may restore up to approximately half of the normal resting coronary artery blood flow (250 mL/min). (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:2054 / 2056
页数:3
相关论文
共 50 条
  • [41] On-pump and off-pump bypass surgery - Tools for Revascularization
    Lytle, BW
    Sabik, JF
    CIRCULATION, 2004, 109 (07) : 810 - 812
  • [42] Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days
    Lamy, Andre
    Devereaux, P. J.
    Prabhakaran, Dorairaj
    Taggart, David P.
    Hu, Shengshou
    Paolasso, Ernesto
    Straka, Zbynek
    Piegas, Leopoldo S.
    Akar, Ahmet Ruchan
    Jain, Anil R.
    Noiseux, Nicolas
    Padmanabhan, Chandrasekar
    Bahamondes, Juan-Carlos
    Novick, Richard J.
    Vaijyanath, Prashant
    Reddy, Sukesh
    Tao, Liang
    Olavegogeascoechea, Pablo A.
    Airan, Balram
    Sulling, Toomas-Andres
    Whitlock, Richard P.
    Ou, Yongning
    Ng, Jennifer
    Chrolavicius, Susan
    Yusuf, Salim
    NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (16): : 1489 - 1497
  • [43] Comparison of the oxidative stress produced by on-pump and off-pump coronary bypass surgery
    Fontaine, David
    Hacquebard, Miriam
    Pradier, Olivier
    Stefanidis, Constantin
    de Caniere, Didier
    Carpentier, Yvon
    Fontaine, Jeanine
    Berkenboom, Guy
    ACTA CARDIOLOGICA, 2008, 63 (01) : 119 - 120
  • [44] A comparison of off-pump and on-pump coronary bypass surgery in patients with low EuroSCORE
    Abdulkadir Ercan
    Ilker Hasan Karal
    Orcun Gurbuz
    Gencehan Kumtepe
    Tolga Onder
    Davit Saba
    Journal of Cardiothoracic Surgery, 9
  • [45] On-Pump Versus Off-Pump Coronary Artery Bypass Surgery in Elderly Patients Results From the Danish On-Pump Versus Off-Pump Randomization Study
    Houlind, Kim
    Kjeldsen, Bo Juul
    Madsen, Susanne Norgaard
    Rasmussen, Bodil Steen
    Holme, Susanne Juel
    Nielsen, Per Hostrup
    Mortensen, Poul Erik
    CIRCULATION, 2012, 125 (20) : 2431 - +
  • [46] Conversion From Off-Pump Coronary Artery Bypass Grafting to On-Pump Coronary Artery Bypass Grafting
    Keeling, Brent
    Thourani, Vinod
    Aliawadi, Gorav
    Kim, Sunghee
    Cyr, Derek
    Badhwar, Vinay
    Jacobs, Jeff
    Brennan, J. Matthew
    Meza, James
    Matsouaka, Roland
    Halkos, Michael E.
    ANNALS OF THORACIC SURGERY, 2017, 104 (04): : 1267 - 1273
  • [47] Results of On-Pump Versus Off-Pump Coronary Artery Bypass Grafting Reply
    Chu, Danny
    Bakaeen, Faisal G.
    ANNALS OF THORACIC SURGERY, 2010, 90 (01): : 358 - 359
  • [48] A comparison of off-pump and on-pump coronary bypass surgery in patients with low EuroSCORE
    Ercan, Abdulkadir
    Karal, Ilker Hasan
    Gurbuz, Orcun
    Kumtepe, Gencehan
    Onder, Tolga
    Saba, Davit
    JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9
  • [49] Off-pump versus on-pump coronary artery bypass grafting—a surreal controversy?
    Kundu A.
    Yadava O.P.
    Taggart D.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2018, 34 (Suppl 3) : 266 - 271
  • [50] Systematic off-pump coronary artery bypass: Risk factor for on-pump conversion
    Hirose, H
    Amano, A
    Li, RZ
    CHEST, 2004, 126 (04) : 828S - 829S