Flow in coronary bypass conduits on-pump and off-pump

被引:18
|
作者
Kjaergard, HK [1 ]
Irmukhamedov, A [1 ]
Christensen, JB [1 ]
Schmidt, TA [1 ]
机构
[1] Univ Copenhagen, Gentofte Hosp, Dept Cardiothorac Surg, DK-2900 Hellerup, Denmark
来源
ANNALS OF THORACIC SURGERY | 2004年 / 78卷 / 06期
关键词
D O I
10.1016/j.athoracsur.2004.06.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of the study was to measure the blood flow in coronary artery bypass grafting conduits on-pump and off-pump and to estimate the total conduit flow. Methods. In a 3.5-year period, 120 patients having coronary artery bypass grafting on-pump and 97 patients having coronary artery bypass grafting off-pump with the left internal mammary artery anastomosed to the left anterior descending artery and saphenous vein grafts to the remaining diseased coronary arteries were included in the study. Flow in the bypass conduits was measured with the transit-time method. Results. In men the left internal mammary artery flow (mean +/- standard error of the mean) was 33.7 +/- 2.0 mL/min on-pump and 34.4 +/- 2.9 off-pump (p > 0.05). In women the left internal mammary artery flow was 29.4 +/- 3.0 mL/min on-pump and 22.8 +/- 1.9 mL/min off-pump (p > 0.05). In men the vein graft flow per anastomosis was 30.4 +/- 1.3 mL/min on-pump and 37.8 +/- 5.4 mL/min off-pump (p > 0.05). In women the vein graft flow per anastomosis was 28.0 +/- 2.9 mL/min on-pump and 23.2 +/- 2.9 mL/min off-pump (p > 0.05). Consistently in women, the mean conduit flows were numerically lower than in men. In patients undergoing coronary artery bypass grafting on-pump the total conduit flows (left internal mammary artery plus vein grafts) were 131.4 +/- 2.5 mL/min in men and 108.4 +/- 3.2 mL/min in women. Conclusions. There were no major differences in conduit flow on-pump versus off-pump. Conventional coronary artery bypass grafting on-pump may restore up to approximately half of the normal resting coronary artery blood flow (250 mL/min). (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:2054 / 2056
页数:3
相关论文
共 50 条
  • [1] On-pump and off-pump coronary bypass surgery
    Lytle, Bruce W.
    CIRCULATION, 2007, 116 (10) : 1108 - 1109
  • [2] On-pump and off-pump coronary artery bypass grafting
    Shekar, PS
    CIRCULATION, 2006, 113 (04) : E51 - E52
  • [3] Off-pump versus on-pump coronary bypass surgery
    Desai, ND
    Fremes, SE
    NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (17): : 1792 - 1792
  • [4] Routine Off-Pump Coronary Artery Bypass: Reasons for On-Pump Conversion Routine Off-Pump Coronary Artery Bypass: Reasons for On-Pump Conversion
    Hirose, Hitoshi
    Amano, Atsushi
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2005, 1 (01) : 28 - 31
  • [5] Off-pump versus on-pump coronary bypass surgery - Response
    van Dijk, D
    de Jaegere, PPT
    Jansen, EWL
    Nathoe, HM
    Diephuis, JC
    Borst, C
    Buskens, E
    Grobbee, DE
    Nierich, AP
    Suyker, WJL
    van Boven, WJ
    CIRCULATION, 2002, 105 (25) : A198 - A198
  • [6] Off-Pump Versus On-Pump Coronary Artery Bypass Grafting
    Moller, Christian H.
    Steinbruechel, Daniel A.
    CURRENT CARDIOLOGY REPORTS, 2014, 16 (03)
  • [7] On-pump versus off-pump coronary artery bypass grafting
    Gardner, Timothy J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (01): : 1 - 1
  • [8] Role of coronary collaterals in off-pump and on-pump coronary bypass surgery
    Nathoe, HM
    Buskens, E
    Jansen, EWL
    Suyker, WJL
    Stella, PR
    Lahpor, JR
    van Boven, WJ
    van Dijk, D
    Diephuis, JC
    Borst, C
    Moons, KGM
    Grobbee, DE
    de Jaegere, PPT
    CIRCULATION, 2004, 110 (13) : 1738 - 1742
  • [9] Off-Pump or On-Pump Coronary-Artery Bypass Grafting
    Sun, Xiaoning
    Wang, Chunsheng
    NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (02): : 194 - 194
  • [10] Off-pump versus on-pump coronary bypass surgery - Reply
    Khan, NE
    DeSouza, AC
    NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (17): : 1793 - 1793