The effects of the shallow and the deep endotracheal suctioning on oxygen saturation and heart rate in high-risk infants

被引:9
|
作者
Youngmee, A
Yonghoon, J
机构
[1] Inha Univ, Dept Nursing, Coll Med, Nam Ku, Inchon 402751, South Korea
[2] Inha Univ, Coll Med, Chung Ku, Inchon 400103, South Korea
关键词
premature infants; endotracheal suctioning; oxygen saturation; heart rate;
D O I
10.1016/S0020-7489(02)00034-2
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
An experimental study involving repeated-measures within subjects was conducted to examine the effects of shallow and deep endotracheal suctioning (ETS) on the SpO2 and HR in 27 ventilated high-risks infants. The order in which subjects received the ETS protocol was randomly assigned. The results showed no significant changes in both the SpO2 and HR responses before, during and after ETS between the two ETS protocols. It is concluded that when there is no beneficial effect of performing deep ETS, it should not be carried out due to the potential hazard of direct irritation with more negative pressure on the airways in high-risk infants. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [41] Measuring Cerebral and Splanchnic Oxygen Saturation of High-Risk Infants During Oral Feeding Near the Time of Discharge From Neonatal Intensive Care
    Sannareddy, Prashamsa
    ADVANCES IN NEONATAL CARE, 2022, 22 (03) : E85 - E85
  • [42] Longitudinal Changes in Suck-Swallow-Breathe, Oxygen Saturation, and Heart Rate Patterns in Term Breastfeeding Infants
    Sakalidis, Vanessa S.
    Kent, Jacqueline C.
    Garbin, Catherine P.
    Hepworth, Anna R.
    Hartmann, Peter E.
    Geddes, Donna T.
    JOURNAL OF HUMAN LACTATION, 2013, 29 (02) : 236 - 245
  • [43] A Physiological/Model Study on the Effects of Deep Breathing on the Respiration Rate, Oxygen Saturation, and Cerebral Oxygen Delivery in Humans
    K. S. Cheng
    P. F. Lee
    Neurophysiology, 2018, 50 : 351 - 356
  • [44] Low signal quality pulse oximetry measurements in newborn infants are reliable for oxygen saturation but underestimate heart rate
    Narayen, Ilona C.
    Smit, Marrit
    van Zwet, Erik W.
    Dawson, Jennifer A.
    Blom, Nico A.
    te Pas, Arjan B.
    ACTA PAEDIATRICA, 2015, 104 (04) : E158 - E163
  • [45] Reference Ranges for Preductal Oxygen Saturation and Heart Rate in Moderate and Late Preterm Infants with Deferred Cord Clamping
    Valles-Murcia, Nerea
    Solaz-Garcia, Alvaro
    Pinilla-Gonzalez, Alejandro
    Torrejon-Rodriguez, Laura
    Gormaz, Maria
    Escrig-Fernandez, Raquel
    Gonzalez-Timoneda, Alba
    Cernada, Maria
    Vento, Maximo
    NEONATOLOGY, 2024,
  • [46] EFFECTS OF SINGLE-PARENT STATUS ON MOTHERS AND THEIR HIGH-RISK INFANTS
    ALLEN, DA
    AFFLECK, G
    MCGRADE, BJ
    MCQUEENEY, M
    INFANT BEHAVIOR & DEVELOPMENT, 1984, 7 (03): : 347 - 359
  • [47] One hour effects of salbutamol and formoterol on blood pressure, heart rate and oxygen saturation in asthmatics
    Capuchinho-Junior, Geraldo Andrade
    Dias, Ricardo Marques
    da Silva de Carvalho, Sonia Regina
    REVISTA PORTUGUESA DE PNEUMOLOGIA, 2008, 14 (03) : 353 - 361
  • [49] Effects of Slow Deep Breathing at High Altitude on Oxygen Saturation, Pulmonary and Systemic Hemodynamics
    Bilo, Grzegorz
    Revera, Miriam
    Bussotti, Maurizio
    Bonacina, Daniele
    Styczkiewicz, Katarzyna
    Caldara, Gianluca
    Giglio, Alessia
    Faini, Andrea
    Giuliano, Andrea
    Lombardi, Carolina
    Kawecka-Jaszcz, Kalina
    Mancia, Giuseppe
    Agostoni, Piergiuseppe
    Parati, Gianfranco
    PLOS ONE, 2012, 7 (11):
  • [50] Can heart rate variability identify a high-risk state of upcoming seizure?
    Cousyn, Louis
    Dono, Fedele
    Navarro, Vincent
    Chavez, Mario
    EPILEPSY RESEARCH, 2023, 197