Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved

被引:126
|
作者
Sassoon, Adam [1 ]
Nam, Denis [1 ]
Nunley, Ryan [1 ]
Barrack, Robert [1 ]
机构
[1] Washington Univ, Dept Orthopaed Surg, St Louis, MO 63110 USA
关键词
CONVENTIONAL INSTRUMENTATION; MATCHED INSTRUMENTATION; CUTTING BLOCKS; ALIGNMENT; GUIDES; NAVIGATION; ACCURACY; ROTATION; OUTCOMES; SURGEON;
D O I
10.1007/s11999-014-3804-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific cutting blocks have been touted as a more efficient and reliable means of achieving neutral mechanical alignment during TKA with the proposed downstream effect of improved clinical outcomes. However, it is not clear to what degree published studies support these assumptions. We asked: (1) Do patient-specific cutting blocks achieve neutral mechanical alignment more reliably during TKA when compared with conventional methods? (2) Does patient-specific instrumentation (PSI) provide financial benefit through improved surgical efficiency? (3) Does the use of patient-specific cutting blocks translate to improved clinical results after TKA when compared with conventional instrumentation? We performed a systematic review in accordance with Cochrane guidelines of controlled studies (prospective and retrospective) in MEDLINEA (R) and EMBASE(A (R)) with respect to patient-specific cutting blocks and their effect on alignment, cost, operative time, clinical outcome scores, complications, and survivorship. Sixteen studies (Level I-III on the levels of evidence rubric) were identified and used in addressing the first question, 13 (Level I-III) for the second question, and two (Level III) for the third question. Qualitative assessment of the selected Level I studies was performed using the modified Jadad score; Level II and III studies were rated based on the Newcastle-Ottawa scoring system. The majority of studies did not show an improvement in overall limb alignment when PSI was compared with standard instrumentation. Mixed results were seen across studies with regard to the prevalence of alignment outliers when PSI was compared with conventional cutting blocks with some studies demonstrating no difference, some showing an improvement with PSI, and a single study showing worse results with PSI. The studies demonstrated mixed results regarding the influence of PSI on operative times. Decreased operative times were not uniformly observed, and when noted, they were found to be of minimal clinical or financial significance. PSI did reliably reduce the number of instrument trays required for processing perioperatively. The accuracy of the preoperative plan, generated by the PSI manufacturers, was found lacking, often leading to multiple intraoperative changes, thereby disrupting the flow of the operation and negatively impacting efficiency. Limited data exist with regard to the effect of PSI on postoperative function, improvement in pain, and patient satisfaction. Neither of the two studies we identified provided strong evidence to support an advantage favoring the use of PSI. No identified studies addressed survivorship of components placed with PSI compared with those placed with standard instrumentation. PSI for TKA has not reliably demonstrated improvement of postoperative limb or component alignment when compared with standard instrumentation. Although decisive evidence exists to support that PSI requires fewer surgical trays, PSI has not clearly been shown to improve overall surgical efficiency or the cost-effectiveness of TKA. Mid- and long-term data regarding PSI's effect on functional outcomes and component survivorship do not exist and short-term data are scarce. Limited available literature does not clearly support any improvement of postoperative pain, activity, function, or ROM when PSI is compared with traditional instrumentation.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 50 条
  • [21] Improved Radiographic Outcomes With Patient-Specific Total Knee Arthroplasty
    Ivie, Conrad B.
    Probst, Patrick J.
    Bal, Amrit K.
    Stannard, James T.
    Crist, Brett D.
    Bal, B. Sonny
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11): : 2100 - 2103
  • [22] Patient-specific instrumentation in total ankle arthroplasty
    Mazzotti, Antonio
    Arceri, Alberto
    Zielli, Simone
    Bonelli, Simone
    Viglione, Valentina
    Faldini, Cesare
    WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (03): : 230 - 237
  • [23] Patient-specific instrumentation for total shoulder arthroplasty
    Gomes, Nuno Sampaio
    EFORT OPEN REVIEWS, 2016, 1 (05): : 177 - 182
  • [24] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Chen, Jerry Yongqiang
    Yeo, Seng Jin
    Yew, Andy Khye Soon
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Chin, Pak Lin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) : 630 - 635
  • [25] Patient-Specific Instrumentation in Total Knee Arthroplasty Provides No Improvement in Component Alignment
    Stronach, Benjamin M.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1705 - 1708
  • [26] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Jerry Yongqiang Chen
    Seng Jin Yeo
    Andy Khye Soon Yew
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Pak Lin Chin
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 630 - 635
  • [27] Reducing Blood Loss in Bilateral Total Knee Arthroplasty with Patient-Specific Instrumentation
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Cushner, Fred D.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 343 - +
  • [28] Preoperative corrections are required for planning of patient-specific instrumentation in total knee arthroplasty
    Okada, Yohei
    Teramoto, Atsushi
    Suzuki, Tomoyuki
    Kii, Yuichiro
    Watanabe, Kota
    Yamashita, Toshihiko
    KNEE, 2017, 24 (06): : 1492 - 1497
  • [29] Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation
    Sébastien Parratte
    Guillaume Blanc
    Thomas Boussemart
    Matthieu Ollivier
    Thomas Le Corroller
    Jean-Noël Argenson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2213 - 2219
  • [30] Patient-Specific Instrumentation Affects Perioperative Blood Loss in Total Knee Arthroplasty
    Cucchi, Davide
    Menon, Alessandra
    Zanini, Beatrice
    Compagnoni, Riccardo
    Ferrua, Paolo
    Randelli, Pietro
    JOURNAL OF KNEE SURGERY, 2019, 32 (06) : 483 - 489