Effect of nitrous oxide on propofol requirement during target-controlled infusion for oocyte retrieval

被引:8
|
作者
Handa-Tsutsui, F. [1 ]
Kodaka, M. [1 ]
机构
[1] Saitama Med Ctr, Dept Anesthesiol, Kawagoe, Saitama, Japan
关键词
target-controlled infusion; in-vitro fertilization; propofol;
D O I
10.1016/j.ijoa.2006.08.001
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Oocyte (egg) retrieval for in-vitro fertilization is a relatively short procedure, usually performed as an outpatient. Propofol is a suitable anesthetic agent. Target-controlled infusion is a recently developed system that aids rapid recovery from propofol anesthesia. This study sought to determine the target concentration of propofol required to prevent movement in 50% (Cp50) and 95% (Cp95) of women during oocyte retrieval, and investigated whether supplemental nitrous oxide (N2O) modified the Cp50 and Cp95. Methods: Forty-seven women scheduled for oocyte retrieval were randomly selected to receive either O-2-air mixture (control group; n = 23) or 50% O-2-N2O mixture (Nitrous oxide group; n = 24). Propofol was infused using a target-controlled infusion system with the concentration determined by up-down sequential allocation using 0.5 mu g/mL step size. Transvaginal oocyte retrieval was performed after reaching target blood concentration. Patient responses to oocyte retrieval were noted as either no movement or movement. Results: Using target-controlled infusion the Cp50 was 4.1 mu g/mL in the control group and 3.3 mu g/mL in the nitrous oxide group. Calculated Cp95 values were 4.0 mu g/mL and 5.1 mu g/mL with and without 50% nitrous oxide respectively. Conclusions: The Cp50 value for target-controlled infusion propofol during oocyte retrieval was significantly reduced by a factor of 1.24 (95% CI 1.07-1.44) with the use of 50% nitrous oxide. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 16
页数:4
相关论文
共 50 条
  • [11] Optimization of target-controlled infusion of propofol for sedation
    Casaletti, E
    Casati, A
    Colnaghi, E
    Cedrati, V
    Passaretta, R
    Magistris, L
    Torri, G
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 : 12 - 12
  • [12] Propofol target-controlled infusion for gastrointestinal endoscopy
    Paramitha, Maharani Pradnya
    Waloejo, Christrijogo Sumartono
    Hamzah
    INTERNATIONAL JOURNAL OF GASTROINTESTINAL INTERVENTION, 2024, 13 (03): : 82 - 85
  • [13] Target-controlled infusion of propofol for fibreoptic intubation
    Knolle, E
    Oehmke, MJ
    Gustorff, B
    Hellwagner, K
    Kress, HG
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2003, 20 (07) : 565 - 569
  • [14] Pharmacokinetics of propofol during conscious sedation using target-controlled infusion
    Oei-Lim, VLB
    BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (04) : 659 - 659
  • [15] Propofol Target-controlled Infusion in Anesthesia Induction during Painless Gastroscopy
    Li, Dong-Ni
    Zhao, Guo-Qing
    Su, Zhen-Bo
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2019, 29 (07): : 604 - 607
  • [16] A comparison of three pharmacokinetic models during target-controlled infusion of propofol
    Glen, J. B.
    White, M.
    ANAESTHESIA, 2012, 67 (06) : 690 - 690
  • [17] MANUAL VS TARGET-CONTROLLED PROPOFOL INFUSION - A COMPARISON OF THE QUALITY OF ANESTHESIA ACHIEVED BY THE INFUSION OF PROPOFOL USING MANUAL OR TARGET-CONTROLLED SYSTEMS
    RUSSELL, D
    WILKES, MP
    GLEN, JB
    HUTTON, P
    KENNY, GNC
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 84 - 84
  • [18] Propofol consumption and recovery from target-controlled anaesthesia:: influence of the nitrous oxide administration
    Harbut, P
    Wysoczanska-Harbut, J
    Boroch, M
    Kübler, A
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 : 144 - 145
  • [19] Propofol sedation with a target-controlled infusion pump in ERCP
    Ogawa, Taiji
    Tomoda, Takeshi
    Kato, Hironari
    Akimoto, Yutaka
    Tanaka, Shoichi
    Okada, Hiroyuki
    GASTROINTESTINAL ENDOSCOPY, 2020, 92 (02) : 301 - 307
  • [20] Setting targets for sedation with a target-controlled propofol infusion
    Janzen, PRM
    Hall, WJ
    Hopkins, PM
    ANAESTHESIA, 2000, 55 (07) : 666 - 669