Problems with modern air-cooled generator stator windings

被引:0
|
作者
Tucker, S [1 ]
Milsom, J [1 ]
Griffith, G [1 ]
Stone, G [1 ]
机构
[1] Natl Power PLC, Selby, England
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The widespread use of air-cooled turbine generators has reduced the capital cost of modern gas-fired and combined cycle plants. However problems have recently been experienced in some of the stator windings in such generators. These problems include deterioration and failure of the insulation in the stator slot due to coil vibration. This has occurred in both conventional and global VPI stators. In addition, some machines have seen problems with partial discharge in the endwinding and lead area due to insufficient spacing between high voltage components. This paper presents examples of these problems, and discusses some repair alternatives.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [21] Application of air-cooled generators to modern power plants
    Gott, BEB
    IEMDC'99 - IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, PROCEEDINGS, 1999, : 317 - 319
  • [22] WORLDS LARGEST CAPACITY AIR-COOLED HYDRO-GENERATOR
    ANAN, T
    FUJITA, J
    SUZUKI, N
    SAKAI, K
    MORI, Y
    GOHDA, K
    SCHMATLOCH, W
    TOSHIBA REVIEW, 1979, (122): : 6 - 10
  • [23] Heat transfer coefficient distribution in inner surface of stator ventilation duct for large capacity air-cooled turbine generator
    Su Ying
    Weili Li
    Wenmao Liu
    Yong Li
    Dong Li
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 146 (05) : 2279 - 2289
  • [24] Research on Stator Main Insulation Temperature Field of Air-Cooled Turbo-Generator after Main Insulation Shelling
    Li, Weili
    Li, Yong
    Su, Ying
    Wang, Purui
    Liu, Wenmao
    ENERGIES, 2018, 11 (05)
  • [25] Hollow Direct Air-Cooled Rotor Windings: Conjugate Heat Transfer Analysis
    Reinap, Avo
    Estenlund, Samuel
    Hogmark, Conny
    MACHINES, 2025, 13 (02)
  • [26] Heat transfer coefficient distribution in inner surface of stator ventilation duct for large capacity air-cooled turbine generator
    Ying Su
    Weili Li
    Wenmao Liu
    Yong Li
    Dong Li
    Journal of Thermal Analysis and Calorimetry, 2021, 146 : 2279 - 2289
  • [27] Experience on the periodic wet bar diagnosis of water-cooled generator stator windings
    Kim, Hee-Soo
    Bae, Yong-Chae
    BALTICA VIII: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 2, 2010, 265 : 253 - 269
  • [28] An Experimental Study on the Dryness Judgement Criterion for Water-cooled Generator Stator Windings
    Kim, Hee Soo
    Bae, Yong Chae
    Lee, Wook Ryun
    Lee, Doo Young
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2010, 34 (02) : 137 - 143
  • [29] Calculation and Analysis of Heat Transfer Coefficients and Temperature Fields of Air-Cooled Large Hydro-Generator Rotor Excitation Windings
    Li Weili
    Zhang Yu
    Chen Yuhong
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (03) : 946 - 952
  • [30] PROBLEMS IN CONSTRUCTING AND DESIGNING COMPONENTS FOR AIR-COOLED EXCHANGERS
    DUMMERSDORF, H
    NOACK, J
    MULLER, G
    CHEMISCHE TECHNIK, 1975, 27 (05): : 310 - 310