Design and Measurement of a New 2.4mm Coaxial Microcalorimeter

被引:0
|
作者
Ding, Sheng [1 ]
Yuan, Wenze [1 ,2 ]
Liu, Jinwen [1 ]
Liu, Xiaomeng [1 ]
Zhao, Wei [1 ]
Cui, Xiaohai [1 ]
机构
[1] Natl Inst Metrol, Beijing, Peoples R China
[2] Beijing Inst Technol, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Microcalorimeter; electromagnetic measurements; power standard;
D O I
10.1109/IWS52775.2021.9499570
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new structure of coaxial microcalorimeter system in 2.4mm coaxial connector is introduced in this paper for metrological purpose, working as primary standard for coaxial radio-frequency (RF) power sensor calibration up to 50 GHz. Proposed apparatus allows direct calibration of the commercial thermoelectric power sensors. Hence assembly procedure is simplified for future calibration service, and traceability chain is shortened as well. Instead of conventional microcalorimeter using thermistor mount as DUT (Device Under Test), proposed microcalorimeter system applies thermoelectric power sensor as DUT which has lower mismatch error, wider working frequency band from 50GHz down to DC and more stable than thermistor mount when working as transfer standard. Eventually, measurement uncertainty is expected to be obviously reduced than thermistor mount.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] 背侧入路2.4mm锁定钢板内固定治疗桡骨远端C3型背侧粉碎性骨折
    彭松明
    黄奎
    临床骨科杂志, 2014, 17 (02) : 224 - 226
  • [42] 2.4mm掌侧双柱锁定加压钢板内固定治疗桡骨远端C型骨折的临床治疗效果
    陈望龙
    季滢瑶
    郑立程
    杨雷
    数理医药学杂志, 2017, 30 (05) : 683 - 684
  • [43] Comparative Analysis of One-Handed and Two-Handed Coaxial Phacoemulsification with 2.4-mm Clear Corneal Incision
    Li, Panpan
    Wu, Jian
    Guan, Yu
    Lu, Zhirong
    Xue, Ying
    Ji, Min
    Guan, Huaijin
    CURRENT EYE RESEARCH, 2019, 44 (03) : 237 - 242
  • [44] 2.4mm万向掌侧双柱锁定加压接骨板内固定治疗老年桡骨远端不稳定骨折
    徐毅
    李海勋
    李智豪
    中医正骨, 2016, (09) : 66 - 69
  • [45] Design of a new phosphate binder, anion exchange resin, based on microcalorimeter measurements
    Inoue, H
    Yamagishi, S
    LETTERS IN DRUG DESIGN & DISCOVERY, 2005, 2 (03) : 250 - 254
  • [46] MEASUREMENT OF VOLTAGE STANDING WAVE RATIO IN A 3.5X1.52-MM COAXIAL WAVEGUIDE
    RYASNYI, YV
    CHEMODANOVA, OB
    MEASUREMENT TECHNIQUES USSR, 1981, 24 (09): : 776 - 779
  • [47] Design, construction, and performance evaluation of a cryogenic 7-mm coaxial noise standard
    Kang, Tae-Weon
    Kim, Jeong-Hwan
    Yurchuk, Eduard F.
    Park, Jeong-II
    Sargsyan, Melik V.
    Arsaev, Igor E.
    Ouzdin, Rinadii I.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) : 439 - 443
  • [48] Improve mm-Wave Measurement Repeatability and Accuracy by Increasing Coaxial Connector Pin Gap
    Wong, Ken
    Hoffmann, Johannes
    2017 IEEE 26TH CONFERENCE ON ELECTRICAL PERFORMANCE OF ELECTRONIC PACKAGING AND SYSTEMS (EPEPS), 2017,
  • [49] A bilateral comparison of measurement of diameters and characteristic impedance of precision 3.5 mm coaxial air lines
    Horibe, Masahiro
    Ridler, Nick
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 474 - +
  • [50] COAXIAL GEOMETRY - A NEW CONCEPT IN EXCIMER LASER DESIGN
    HASTIE, SD
    SANDWELL, R
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1992, 17 (2B): : 297 - 307