Design and Measurement of a New 2.4mm Coaxial Microcalorimeter

被引:0
|
作者
Ding, Sheng [1 ]
Yuan, Wenze [1 ,2 ]
Liu, Jinwen [1 ]
Liu, Xiaomeng [1 ]
Zhao, Wei [1 ]
Cui, Xiaohai [1 ]
机构
[1] Natl Inst Metrol, Beijing, Peoples R China
[2] Beijing Inst Technol, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Microcalorimeter; electromagnetic measurements; power standard;
D O I
10.1109/IWS52775.2021.9499570
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new structure of coaxial microcalorimeter system in 2.4mm coaxial connector is introduced in this paper for metrological purpose, working as primary standard for coaxial radio-frequency (RF) power sensor calibration up to 50 GHz. Proposed apparatus allows direct calibration of the commercial thermoelectric power sensors. Hence assembly procedure is simplified for future calibration service, and traceability chain is shortened as well. Instead of conventional microcalorimeter using thermistor mount as DUT (Device Under Test), proposed microcalorimeter system applies thermoelectric power sensor as DUT which has lower mismatch error, wider working frequency band from 50GHz down to DC and more stable than thermistor mount when working as transfer standard. Eventually, measurement uncertainty is expected to be obviously reduced than thermistor mount.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Realization of 2.4mm coaxial microcalorimeter system as national standard of microwave power from 1 MHz to 50 GHz
    Ahmad, Saood
    Charles, Michael
    Allal, Djamel
    Negi, P. S.
    Ojha, V. N.
    MEASUREMENT, 2018, 116 : 106 - 113
  • [2] The Design and Realization of 2.4mm Switch Blocking Programmable Attenuator
    Wang, Jinlong
    Wen, Chunhua
    Zheng, Wenfeng
    2018 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT2018), 2018,
  • [3] DEVELOPMENT OF A 2.4 mm COAXIAL MICROCALORIMETER FOR POWER MEASUREMENTS UP TO 50 GHz
    Bourghes, M.
    Allal, D.
    Belieres, D.
    Kazemipour, A.
    Litwin, A.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 324 - 325
  • [4] A new microcalorimeter for measurements in 3.5 mm coaxial line
    Brunetti, L
    Vremera, E
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 196 - 197
  • [5] A new microcalorimeter for measurements in 3.5-mm coaxial line
    Brunetti, L
    Vremera, ET
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 320 - 323
  • [6] A 2.4-mm Coaxial Microcalorimeter for Use as Millimeter-Wave Power Standard at CENAM
    Botello-Perez, Mariano
    Kwon, Jae-Yong
    Garcia-Ruiz, Israel
    Jardon-Aguilar, Hildeberto
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70 (70)
  • [7] Effects of pin depth in LCP 3.5mm, 2.4mm, and 1.0mm connectors
    Szendrenyi, BB
    2000 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2000, : 1859 - 1862
  • [8] A design and implementation of 3.5 mm coaxial microcalorimeter for RF and microwave power standards at KRISS
    Kwon, Jae-Yong
    Kang, Tae-Weon
    Kim, Jeong-Hwan
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 422 - 423
  • [9] 2.4mm锁定钢板治疗跟骨关节内骨折
    孔祥喆
    管得印
    蒋刚
    中外医疗, 2015, 34 (04) : 24 - 25
  • [10] 2.4mm锁定钢板治疗跟骨关节内骨折
    孔祥喆
    管得印
    蒋刚
    辽宁医学杂志, 2015, 29 (01) : 15 - 16