A Marker-Less Registration Approach for Mixed Reality-Aided Maxillofacial Surgery: a Pilot Evaluation

被引:59
|
作者
Pepe, Antonio [1 ,2 ]
Trotta, Gianpaolo Francesco [2 ,3 ]
Mohr-Ziak, Peter [1 ,4 ]
Gsaxner, Christina [1 ,2 ]
Wallner, Juergen [2 ,5 ]
Bevilacqua, Vitoantonio [6 ]
Egger, Jan [1 ,2 ,5 ]
机构
[1] Graz Univ Technol, Fac Comp Sci & Biomed Engn, Inst Comp Graph & Vis, A-8010 Graz, Austria
[2] Comp Algorithms Med Lab, Graz, Austria
[3] Polytech Univ Bari, Dept Mech Math & Management, Via Orabona 4, Bari, Italy
[4] VRVis Zentrum Virtual Real & Visualisierung Forsc, Donau City Str 11, A-1220 Vienna, Austria
[5] Med Univ Graz, Dept Oral & Maxillofacial Surg, Auenbruggerpl 5-1, A-8036 Graz, Styria, Austria
[6] Polytech Univ Bari, Dept Elect & Informat Engn, Via Orabona 4, Bari, Italy
基金
奥地利科学基金会;
关键词
Computer Assisted Surgery; Microsoft HoloLens; Pattern Recognition; Head and Neck Cancer; Augmented Reality; Visualization; Facial Landmarks; Registration; SEGMENTATION; HEAD;
D O I
10.1007/s10278-019-00272-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As of common routine in tumor resections, surgeons rely on local examinations of the removed tissues and on the swiftly made microscopy findings of the pathologist, which are based on intraoperatively taken tissue probes. This approach may imply an extended duration of the operation, increased effort for the medical staff, and longer occupancy of the operating room (OR). Mixed reality technologies, and particularly augmented reality, have already been applied in surgical scenarios with positive initial outcomes. Nonetheless, these methods have used manual or marker-based registration. In this work, we design an application for a marker-less registration of PET-CT information for a patient. The algorithm combines facial landmarks extracted from an RGB video stream, and the so-called Spatial-Mapping API provided by the HMD Microsoft HoloLens. The accuracy of the system is compared with a marker-based approach, and the opinions of field specialists have been collected during a demonstration. A survey based on the standard ISO-9241/110 has been designed for this purpose. The measurements show an average positioning error along the three axes of (x, y, z) = (3.3 +/- 2.3, - 4.5 +/- 2.9, - 9.3 +/- 6.1) mm. Compared with the marker-based approach, this shows an increment of the positioning error of approx. 3 mm along two dimensions (x, y), which might be due to the absence of explicit markers. The application has been positively evaluated by the specialists; they have shown interest in continued further work and contributed to the development process with constructive criticism.
引用
收藏
页码:1008 / 1018
页数:11
相关论文
共 21 条
  • [21] Automated Marker-Less Patient-to-Preoperative Medical Image Registration Approach Using RGB-D Images and Facial Landmarks for Potential Use in Computed-Aided Surgical Navigation of the Paranasal Sinus
    Kim, Suhyeon
    An, Haill
    Song, Myungji
    Lee, Sungmin
    Jung, Hoijoon
    Kim, Seontae
    Jung, Younhyun
    ADVANCES IN COMPUTER GRAPHICS, CGI 2023, PT IV, 2024, 14498 : 135 - 145