Study on the operation performance of STATCOM under unbalanced and distorted system voltage

被引:0
|
作者
Shen, D [1 ]
Liu, WH [1 ]
Wang, ZH [1 ]
机构
[1] Univ Toronto, Dept Elect & Comp Engn, Toronto, ON M5S 3G4, Canada
关键词
STATCOM; voltage distortion; digital simulation; experimental test;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The operation performance of Static Synchronous Compensators (STATCOMs) under unbalanced and distorted system voltage is a great concern of designers and operation engineers. Based on a novel per-unit STATCOM mathematical model, this paper makes a theoretical analysis of STATCOM performance under distorted system voltage. Algebraic expressions as well as the 3-D curves are given to reveal the relationship between STATCOM harmonics and the main circuit parameters. The theoretical analysis was verified by digital simulation results of PSCAD/EMTDC and tests on a 10kvar prototype experimental device. The good agreement between the analytical results and the experimental results show that the approach proposed in this paper can be used to select the passive elements and assess the operation performance of STATCOM under unbalanced or distorted system voltage.
引用
收藏
页码:2630 / 2635
页数:2
相关论文
共 50 条
  • [21] Performance Study of Different PLL Schemes Under Unbalanced Grid Voltage
    Singh, Utsava Kumar
    Basak, Abhinandan
    PROCEEDINGS OF 2019 IEEE REGION 10 SYMPOSIUM (TENSYMP), 2019, : 66 - 71
  • [22] A new mathematical model and control of D-StatCom for operation under unbalanced conditions
    Blazic, B
    Papic, I
    ELECTRIC POWER SYSTEMS RESEARCH, 2004, 72 (03) : 279 - 287
  • [23] Voltage Control of a StatCom at a Fixed Speed Wind Farm under Unbalanced Grid Faults
    Wessels, Christian
    Fuchs, Friedrich W.
    Molinas, Marta
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 979 - 984
  • [24] STATCOM operation strategy under power system faults
    Xi, Zhengping
    Bhattacharya, Subhashish
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 4308 - +
  • [25] Enhancement of DFIG Operation Using a STATCOM Under a Voltage Grid Faults
    Kamel, Sayahi
    Mansour, Baazouzi
    Faouzi, Bacha
    2022 8TH INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT'22), 2022, : 1550 - 1555
  • [26] Response of D-STATCOM under unbalanced voltage condition caused by SLG fault
    Wahab, NIA
    Mariun, N
    Mohamed, A
    Mohamad, M
    SCORED 2003: STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT, PROCEEDINGS: NETWORKING THE FUTURE MIND IN CONVERGENCE TECHNOLOGY, 2003, : 395 - 400
  • [27] A Control Scheme for H-bridge STATCOM Under Unbalanced System
    Jie, Zhou
    Yong, Wang
    Liu Ruidong
    Shi Zhiyong
    2012 2ND INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY (CARPI), 2012, : 98 - 101
  • [28] Voltage Support Provided by STATCOM in Unbalanced Power Systems
    Rodriguez, Ana
    Bueno, Emilio J.
    Mayor, Alvar
    Rodriguez, Francisco J.
    Garcia-Cerrada, Aurelio
    ENERGIES, 2014, 7 (02) : 1003 - 1026
  • [29] Rotor current controller with voltage harmonics compensation for a DFIG operating under unbalanced and distorted stator voltage
    Ramos, C. J.
    Martins, A. P.
    Carvalho, A. S.
    IECON 2007: 33RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, CONFERENCE PROCEEDINGS, 2007, : 1287 - 1292
  • [30] Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller
    Lee, Jong-Hyun
    Jeong, Hae-Gwang
    Lee, Kyo-Beum
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (06) : 918 - 925