Haemodynamic effects of patent foramen ovale and atrial septal defect closure: a comparison during percutaneous shunt closure

被引:4
|
作者
Luermans, Justin G. L. M. [1 ]
Bos, Willem J. W. [2 ]
Post, Martijn C. [1 ]
ten Berg, Jurrien M. [1 ]
Plokker, H. W. Thijs [1 ]
Suttorp, Maarten J. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Internal Med, NL-3435 CM Nieuwegein, Netherlands
关键词
atrial septal defect; Finometer; haemodynamics; patent foramen ovale; transcatheter closure; TRANSCATHETER CLOSURE; ARTERIAL-PRESSURE; FINGER; HUMANS; FLOW;
D O I
10.1111/j.1475-097X.2009.00905.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
P>Objectives: We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Background: Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Methods: Twenty-five consecutive patients (mean age 49 +/- 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer (R). Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow (R) methodology. Results: Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7 center dot 1 +/- 5 center dot 4 (P = 0 center dot 003), 3 center dot 8 +/- 3 center dot 5 (P = 0 center dot 007) and 2 center dot 0 +/- 3 center dot 0 mmHg (P = ns) respectively. HR decreased 5 center dot 1 +/- 5 center dot 3 beats per minute (P = 0 center dot 01). SV, CO and TPR increased 8 center dot 5 +/- 6 center dot 4 ml (13 center dot 5%; P = 0 center dot 002), 0 center dot 21 +/- 0 center dot 45 l min-1 (5 center dot 6%; P = ns) and 0 center dot 02 +/- 0 center dot 14 dynes (4 center dot 1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0 center dot 009). Conclusions: Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [41] A Retrospective Analysis of Self-Limiting Fever following Percutaneous Patent Foramen Ovale and Atrial Septal Defect Closure
    Galasso, Francesca
    Wassenaar, Felicia
    Barry, Timothy
    Baqal, Omar J.
    Hagler, Donald J.
    Sweeney, John P.
    Fortuin, F. David
    CARDIOLOGY RESEARCH AND PRACTICE, 2024, 2024
  • [42] Patent foramen ovale/atrial septal defect closure and migraine: Searching the rationale for the procedure - Reply
    Tobis, J
    Azarbal, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (04) : 738 - 739
  • [43] Adverse events associated with nickel allergy in patients undergoing percutaneous atrial septal defect or patent foramen ovale closure
    Wertman, B
    Azarbal, B
    Riedl, M
    Tobis, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) : 1226 - 1227
  • [44] Feasibility and early outcomes of atrial septal defect prostheses use for percutaneous closure of widely open patent foramen ovale
    Dupuy, M.
    Guedeney, P.
    Silvain, J.
    Zeitouni, M.
    Devos, P.
    Wallet, T.
    Bouziri, N.
    Procopi, N.
    Hammoudi, N.
    Montalescot, G.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [45] Current indications and contraindications for transcatheter atrial septal defect and patent foramen ovale device closure
    Valente, Anne Marie
    Rhodes, John F.
    AMERICAN HEART JOURNAL, 2007, 153 (04)
  • [46] Value of Intracardiac Echocardiography in the Interventional Closure of Patent Foramen Ovale with Adjacent Atrial Septal Defect
    Zhu, Boqian
    Zhu, Tao
    Fan, Jianing
    Zhang, Xiaochun
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2024, 2024
  • [47] Surgical management of complications after transcatheter closure of an atrial septal defect or patent foramen ovale
    Berdat, PA
    Chatterjee, T
    Pfammatter, JP
    Windecker, S
    Meier, B
    Carrel, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (06): : 1034 - 1039
  • [48] Intracardiac Echocardiography during Atrial Septal Defect and Patent Foramen Ovale Device Closure in Pediatric and Adolescent Patients
    Medford, Beth A.
    Taggart, Nathaniel W.
    Cabalka, Allison K.
    Cetta, Frank
    Reeder, Guy S.
    Hagler, Donald J.
    Johnson, Jonathan N.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (09) : 984 - 990
  • [49] Interventional closure of atrial septal defect and patent foramen ovale in adults with the ASDOS-umbrella
    Rux, S
    Dirks, J
    Keppeler, P
    Babic, U
    Fach, WA
    Scherer, D
    Schrader, R
    Sievert, H
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 : TC244 - TC244
  • [50] Modified Technique to Control the Eutachian Valve During Transcatheter Closure of Atrial Septal Defect/Patent Foramen Ovale
    El Shedoudy, Sahar
    Abo Elsoud, Fatma
    El Dokhlaha, Eman
    Rashed, Reem
    Abdelghani, Mohammad
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0D)