Patient dose from barium procedures

被引:51
|
作者
Ruiz-Cruces, R
Ruiz, F
Pérez-Martínez, M
López, J
Ausina, IT
de los Ríos, AD
机构
[1] Univ Malaga, Sch Med, Radiol & Med Phys Dept, E-29071 Malaga, Spain
[2] Univ Malaga, Sch Med, Res Grp Radioprotect & Med Phys, E-29071 Malaga, Spain
[3] Virgen Victoria Univ Hosp, Dept Radiol, Digest Radiol Unit, Malaga, Spain
来源
BRITISH JOURNAL OF RADIOLOGY | 2000年 / 73卷 / 871期
关键词
D O I
10.1259/bjr.73.871.11089468
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this work was to estimate patient doses (dose-area product. organ dose, effective dose and entrance surface dose) for barium procedures. A total of 175 procedures. in 175 patients, for five different examination categories was analysed. Dose-area product was determined using a transmission ionization chamber. Organ dose and effective dose were assessed using a knowledge of the examination and the software. For all patients, the contribution of fluoroscopy to the total dose was greater than that from radiography. Dose-area product from double contrast barium enema, enteroclysis and intestinal tract procedures was higher than that obtained for the other procedures. The average effective dose was 1.04 mSv and 13.99 mSv for oesophageal tract and enteroclysis examinations, respectively. Entrance surface dose in the oesophageal tract was 16 mGy, 10 times lower than for the other four procedures. Patient dose reduction in barium procedures may be achieved by improved training of resident radiologists, senior radiologists and other specialists in radiation protection.
引用
收藏
页码:752 / 761
页数:10
相关论文
共 50 条
  • [41] PATIENT DOSAGES FROM TOMOGRAPHIC PROCEDURES
    CROSBY, EH
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (02): : 370 - &
  • [42] Patient doses from neuroradiological procedures
    Boal, T.
    Dixon, R.
    Australasian Physical and Engineering Sciences in Medicine, 1999, 22 (04): : 153 - 162
  • [43] ABSORBED DOSE TO THE RADIOLOGIST FROM ANGIOGRAPHIC PROCEDURES
    TRYHUS, M
    METTLER, FA
    KELSEY, CA
    STEVENS, GF
    ORRISON, W
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S31 - S31
  • [44] GONAD RADIATION DOSE FROM DIAGNOSTIC PROCEDURES
    ARDRAN, GM
    CROOKS, HE
    BRITISH JOURNAL OF RADIOLOGY, 1957, 30 (354): : 295 - 297
  • [45] Patient's skin dose estimation and investigation of factors for dose reduction in fluoroscopy guided procedures
    Nana, Ruth Njantang
    Gyekye, Prince Kwabena
    Inkoom, Stephen
    Hasford, Francis
    Fokou, Mvoufo
    Ndontchueng, Maurice Moyo
    Motapon, Ousmanou
    HEALTH AND TECHNOLOGY, 2024, 14 (03) : 487 - 494
  • [46] Patient’s skin dose estimation and investigation of factors for dose reduction in fluoroscopy guided procedures
    Ruth Njantang Nana
    Prince Kwabena Gyekye
    Stephen Inkoom
    Francis Hasford
    Mvoufo Fokou
    Maurice Moyo Ndontchueng
    Ousmanou Motapon
    Health and Technology, 2024, 14 : 487 - 494
  • [47] Effective dose to patient during cardiac interventional procedures (Prague workplaces)
    Stisova, V
    RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) : 271 - 274
  • [48] A mathematical model for patient skin dose assessment in cardiac catheterization procedures
    Morrell, R. E.
    Rogers, A. T.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (945): : 756 - 761
  • [49] Patient skin dose in interventional procedures as measured by a portal film technique
    Kuan, HM
    Lawson, WE
    Manzione, JV
    Ferretti, JA
    Birk, JW
    Dignam, VA
    RADIOLOGY, 2000, 217 : 591 - 591
  • [50] Dose reduction for fluoroscopically guided injections: phantom simulation and patient procedures
    C. Y. Chang
    F. J. Simeone
    M. C. DeLorenzo
    W. E. Palmer
    M. A. Bredella
    A. J. Huang
    Skeletal Radiology, 2018, 47 : 223 - 231