Long-Term Clinical Outcomes and Survivorship of Press-Fit Condylar Sigma Fixed-Bearing and Mobile-Bearing Total Knee Prostheses in the Same Patients

被引:30
|
作者
Kim, Young-Hoo [1 ]
Park, Jang-Won [1 ]
Kim, Jun-Shik [1 ]
Kulkarni, Sourabh S. [1 ]
Kim, Yoon-Hong [1 ]
机构
[1] Ewha Womans Univ, Sch Med, Ctr Joint Replacement, Seoul 158710, South Korea
来源
关键词
IN-VIVO KINEMATICS; ROTATING-PLATFORM; JOINT REPLACEMENT; OXFORD KNEE; VALGUS KNEE; FOLLOW-UP; ARTHROPLASTY; DISLOCATION; SYSTEM;
D O I
10.2106/JBJS.M.01130
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. Methods: The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 +/- 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. Results: Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129 degrees +/- 6.3 degrees and 127 degrees +/- 6.8 degrees), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. Conclusions: The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and fixed-bearing cruciate-retaining total knee designs. We found no significant clinical advantage for a mobile-bearing over a fixed-bearing total knee prosthesis.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Higher forgotten joint score for fixed-bearing than for mobile-bearing total knee arthroplasty
    Thienpont, E.
    Zorman, D.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2641 - 2645
  • [32] Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy
    Hernigou, Philippe
    Huys, Maxime
    Pariat, Jacques
    Roubineau, Francois
    Lachaniette, Charles Henri Flouzat
    Dubory, Arnaud
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (02) : 317 - 322
  • [33] Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy
    Philippe Hernigou
    Maxime Huys
    Jacques Pariat
    François Roubineau
    Charles Henri Flouzat Lachaniette
    Arnaud Dubory
    International Orthopaedics, 2018, 42 : 317 - 322
  • [34] Long-Term (Up to 27 Years) Prospective, Randomized Study of Mobile-Bearing and Fixed-Bearing Total Knee Arthroplasties in Patients <60 Years of Age With Osteoarthritis
    Kim, Young-Hoo
    Park, Jang-Won
    Jang, Young-Soo
    JOURNAL OF ARTHROPLASTY, 2021, 36 (04): : 1330 - 1335
  • [35] Patellofemoral kinematics in mobile-bearing and fixed-bearing posterior stabilised total knee replacements: a cadaveric study
    Heinert, G.
    Kendoff, D.
    Preiss, S.
    Gehrke, T.
    Sussmann, P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (06) : 967 - 972
  • [36] Long-term followup after mobile-bearing total knee replacement
    Buechel, FF
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) : 40 - 50
  • [37] Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis: a matched pair analysis
    Florian Geiger
    Hans Mau
    Marlis Krüger
    Marc Thomsen
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 285 - 291
  • [38] Patellofemoral kinematics in mobile-bearing and fixed-bearing posterior stabilised total knee replacements: a cadaveric study
    G. Heinert
    D. Kendoff
    S. Preiss
    T. Gehrke
    P. Sussmann
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 967 - 972
  • [39] Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis:: a matched pair analysis
    Geiger, Florian
    Mau, Hans
    Krueger, Marlis
    Thomsen, Marc
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (03) : 285 - 291
  • [40] Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses
    D. Biau
    M. M. Mullins
    T. Judet
    P. Piriou
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 927 - 933