Accuracy in the determination of isoelectric points of some proteins and a peptide by capillary isoelectric focusing: Utility of synthetic peptides as isoelectric point markers

被引:54
|
作者
Shimura, K [1 ]
Zhi, W
Matsumoto, H
Kasai, K
机构
[1] Teikyo Univ, Fac Pharmaceut Sci, Sagamihara, Kanagawa 1990195, Japan
[2] Lab Mol Biophoton, Shizuoka 434, Japan
关键词
D O I
10.1021/ac000387o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To evaluate the accuracy of isoelectric point determination by capillary isoelectric focusing, the pi values of nine proteins and a peptide, the pI values of which had been determined by other methods and ranging pI 3.55-9.60, were determined by capillary isoelectric focusing by cofocusing of recently developed peptide pI markers ranging 3.38-10.17, and the consistency of the pI values was examined. Isoelectric focusing was carried oud in neutral polymer-coated capillaries, and the pH gradient was mobilized by pressure toward the cathode, to detect samples with absorption at 280 nm at a fixed detection point. Carrier ampholytes from two different suppliers and in different pH ranges were used. The sharp peaks of the highly pure peptide pI markers greatly facilitated the unambiguous identification of the peaks. When a carrier ampholyte ranging over the acidic side was used, the detection of acidic pI samples was anomalously delayed. This could be partly mitigated by reducing the viscosity of the anode solution in comparison with the pH gradient formed in the capillary. Since the detection times vs the pH relationships were not linear in most cases, the use of a linear calibration line over an entire pH gradient would be erroneous. Instead, the pI values of samples were calculated by assuming a linear relation for pH against detection time between two nanking marker peptides. Close agreement between the pI values, determined by capillary isoelectric focusing, and the reference values of the samples was observed within an average difference range of 0.04-0.08 pH unit with a sample consumption of 10-100 ng within 30-60 min. Some carrier ampholytes were preferentially more effective at either the acidic or the basic side of the pH gradient. For confirmation of the completion of focusing, the use of two different focusing times is recommended.
引用
收藏
页码:4747 / 4757
页数:11
相关论文
共 50 条
  • [21] ISOELECTRIC POINTS OF PROTEINS, DETERMINED BY ISOELECTRIC-FOCUSING IN THE PRESENCE OF UREA AND ETHANOL
    GELSEMA, WJ
    DELIGNY, CL
    VANDERVEEN, NG
    JOURNAL OF CHROMATOGRAPHY, 1979, 171 (APR): : 171 - 181
  • [22] Current trends in capillary isoelectric focusing of proteins
    Righetti, PG
    Gelfi, C
    Conti, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 699 (1-2): : 91 - 104
  • [23] Recent advances in isoelectric focusing of proteins and peptides
    Farmerie, Lily
    Rustandi, Richard R.
    Loughney, John W.
    Dawod, Mohamed
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1651
  • [24] DETERMINATION OF ISOELECTRIC POINTS OF THE BEET PROTEINS
    SVACHULA, V
    SVACHULOVA, J
    LISTY CUKROVARNICKE A REPARSKE, 1983, 99 (05): : 97 - 99
  • [25] ISOELECTRIC POINTS OF PROTEINS - THEORETICAL DETERMINATION
    SILLERO, A
    RIBEIRO, JM
    ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) : 319 - 325
  • [26] Peak identification in capillary isoelectric focusing using the concept of relative peak position as determined by two isoelectric point markers
    Wu, Jiaqi
    Huang, Tiemin
    ELECTROPHORESIS, 2006, 27 (18) : 3584 - 3590
  • [27] High-efficiency capillary isoelectric focusing of peptides
    Shen, YF
    Berger, SJ
    Anderson, GA
    Smith, RD
    ANALYTICAL CHEMISTRY, 2000, 72 (09) : 2154 - 2159
  • [28] Simultaneous determination of ionization constants and isoelectric points of 12 hydroxy-s-triazines by capillary zone electrophoresis and capillary isoelectric focusing
    Schmitt, P
    Poiger, T
    Simon, R
    Freitag, D
    Kettrup, A
    Garrison, AW
    ANALYTICAL CHEMISTRY, 1997, 69 (13) : 2559 - 2566
  • [29] Capillary isoelectric focusing with whole column imaging detection for analysis of proteins and peptides
    Mao, QL
    Pawliszyn, J
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1999, 39 (1-2): : 93 - 110
  • [30] Capillary isoelectric focusing as a tool in the examination of antibodies, peptides and proteins of pharmaceutical interest
    Liu, X
    Sosic, Z
    Krull, IS
    JOURNAL OF CHROMATOGRAPHY A, 1996, 735 (1-2) : 165 - 190