Examination of musculoskeletal chest pain - An inter-observer reliability study

被引:9
|
作者
Brunse, Mads Hostrup [1 ,2 ]
Stochkendahl, Mette Jensen [1 ,2 ]
Vach, Werner [1 ,3 ]
Kongsted, Alice [1 ]
Poulsen, Erik [1 ,2 ]
Hartvigsen, Jan [1 ,2 ]
Christensen, Henrik Wulff [1 ,2 ]
机构
[1] Nord Inst Chiropract & Clin Biomech, Odense, Denmark
[2] Univ So Denmark, Inst Sports Sci & Clin Biomech, Odense, Denmark
[3] Univ So Denmark, Dept Stat, Odense, Denmark
关键词
Reliability; Palpation procedure; Physical examination; Chest pain; CLINICAL-PREDICTION RULE; LOW-BACK-PAIN; THORACIC SPINE; INTERRATER RELIABILITY; INTERVERTEBRAL MOTION; CLASSIFICATION-SYSTEM; LUMBAR SPINE; NECK PAIN; PALPATION; TESTS;
D O I
10.1016/j.math.2009.10.003
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Chest pain may be caused by joint and muscle dysfunction of the neck and thorax (termed musculoskeletal chest pain). The objectives of this study were (1) to determine inter-observer reliability of the diagnosis 'musculoskeletal chest pain' in patients with acute chest pain of non-cardiac origin using a standardized examination protocol, (2) to determine inter-observer reliability of single components of the protocol, and (3) to determine the effect of observer experience. Eighty patients were recruited from an emergency cardiology department. Patients were eligible if an obvious cardiac or non-cardiac diagnosis could not be established at the cardiology department. Four observers (two chiropractors and two chiropractic students) performed general health and manual examination of the spine and chest wall. Percentage agreement, Cohen's Kappa and ICC were calculated for observer pairs (chiropractors and students) and all. Musculoskeletal chest pain was diagnosed in 45 percent of patients. Inter-observer kappa values were substantial for the chiropractors and overall (0.73 and 0.62, respectively), and moderate for the students (0.47). For single items of the protocol, the overall kappa ranged from 0.01 to 0.59. Provided adequate training of observers, the examination protocol can be used in carefully selected patients in clinical settings and should be included in pre- and post-graduate clinical training. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [31] Inter-observer Reliability of the Pediatric NIH Stroke Scale (PedNIHSS) in a Multicenter Study
    Ichord, Rebecca N.
    Bastian, Rachel
    Abraham, Lisa
    Askalan, Rand
    Benedict, Susan
    Bernard, Timothy
    Beslow, Lauren
    deVeber, Gabrielle
    Dowling, Michael
    Friedman, Neil
    Fullerton, Heather
    Jordan, Lori
    Kan, Li
    Kirton, Adam
    Amlie-Lefond, Catherine
    Licht, Daniel
    Lo, Warren
    McClure, Chalmer
    Pavlakis, Steve
    Smith, Sabrina E.
    Tan, Marilyn
    Jawad, Abbas F.
    STROKE, 2011, 42 (03) : E98 - E98
  • [32] A Study of Inter-observer Agreements of Spiral Chest Computed Tomography in Diagnosing Pulmonary Embolism
    Kim, Yang-Ki
    Lee, Young Mok
    Kim, Ki-up
    Uh, Soo-taek
    Kim, Yong Hoon
    Park, Choon Sik
    Hwang, Jung-Hwa
    Kim, Dong Hun
    Goo, Dong-Erk
    Choi, Deuk-Lin
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2005, 59 (05) : 473 - 479
  • [33] INTRA-OBSERVER AND INTER-OBSERVER VARIATION IN FUNCTIONAL EXAMINATION OF THE MASTICATORY SYSTEM
    CARLSSON, GE
    EGERMARKERIKSSON, I
    MAGNUSSON, T
    SWEDISH DENTAL JOURNAL, 1980, 4 (05) : 187 - 194
  • [34] Intra-observer and inter-observer agreement of the manual examination of the lumbar spine in chronic low-back pain
    Etienne Qvistgaard
    Jens Rasmussen
    Jes Lætgaard
    Steen Hecksher-Sørensen
    Henning Bliddal
    European Spine Journal, 2007, 16 : 277 - 282
  • [35] Intra-observer and inter-observer agreement of the manual examination of the lumbar spine in chronic low-back pain
    Qvistgaard, Etienne
    Rasmussen, Jens
    Laetgaard, Jes
    Hecksher-Sorensen, Steen
    Bliddal, Henning
    EUROPEAN SPINE JOURNAL, 2007, 16 (02) : 277 - 282
  • [36] Inter-observer and Intra-observer Reliability of Measurements of the Obliquity of Palpebral Fissures
    Davis, Amy Livingston
    Twelker, John Daniel
    Miller, Joseph M.
    Harvey, Erin M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [37] Probing the effect of OSCE checklist length on inter-observer reliability and observer accuracy
    Hurley, Katrina F.
    Giffin, Nick A.
    Stewart, SamuelA.
    Bullock, Graham B.
    MEDICAL EDUCATION ONLINE, 2015, 20
  • [38] Intra- and inter-observer reliability of MRI examination of intervertebral disc abnormalities in patients with cervical myelopathy
    Braga-Baiak, Andresa
    Shah, Arland
    Pietrobon, Ricardo
    Braga, Larissa
    Neto, Arnolfo Carvalho
    Cook, Chad
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) : 91 - 98
  • [39] Inter-observer reliability of localization of recorded stridor sounds in children
    Zwartenkot, Joost W.
    Hoeve, Hans L. J.
    Borgstein, Johannes
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2010, 74 (10) : 1184 - 1188
  • [40] Care protocols with risk classification in pediatrics: inter-observer reliability
    Magalhaes, Fernanda Jorge
    Teixeira Lima, Francisca Elisagela
    Almeida, Paulo Cesar
    Ximenes, Lorena Barbosa
    Pessoa Chaves, Caroline Magna
    ACTA PAULISTA DE ENFERMAGEM, 2017, 30 (03) : 262 - 270