Examination of musculoskeletal chest pain - An inter-observer reliability study

被引:9
|
作者
Brunse, Mads Hostrup [1 ,2 ]
Stochkendahl, Mette Jensen [1 ,2 ]
Vach, Werner [1 ,3 ]
Kongsted, Alice [1 ]
Poulsen, Erik [1 ,2 ]
Hartvigsen, Jan [1 ,2 ]
Christensen, Henrik Wulff [1 ,2 ]
机构
[1] Nord Inst Chiropract & Clin Biomech, Odense, Denmark
[2] Univ So Denmark, Inst Sports Sci & Clin Biomech, Odense, Denmark
[3] Univ So Denmark, Dept Stat, Odense, Denmark
关键词
Reliability; Palpation procedure; Physical examination; Chest pain; CLINICAL-PREDICTION RULE; LOW-BACK-PAIN; THORACIC SPINE; INTERRATER RELIABILITY; INTERVERTEBRAL MOTION; CLASSIFICATION-SYSTEM; LUMBAR SPINE; NECK PAIN; PALPATION; TESTS;
D O I
10.1016/j.math.2009.10.003
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Chest pain may be caused by joint and muscle dysfunction of the neck and thorax (termed musculoskeletal chest pain). The objectives of this study were (1) to determine inter-observer reliability of the diagnosis 'musculoskeletal chest pain' in patients with acute chest pain of non-cardiac origin using a standardized examination protocol, (2) to determine inter-observer reliability of single components of the protocol, and (3) to determine the effect of observer experience. Eighty patients were recruited from an emergency cardiology department. Patients were eligible if an obvious cardiac or non-cardiac diagnosis could not be established at the cardiology department. Four observers (two chiropractors and two chiropractic students) performed general health and manual examination of the spine and chest wall. Percentage agreement, Cohen's Kappa and ICC were calculated for observer pairs (chiropractors and students) and all. Musculoskeletal chest pain was diagnosed in 45 percent of patients. Inter-observer kappa values were substantial for the chiropractors and overall (0.73 and 0.62, respectively), and moderate for the students (0.47). For single items of the protocol, the overall kappa ranged from 0.01 to 0.59. Provided adequate training of observers, the examination protocol can be used in carefully selected patients in clinical settings and should be included in pre- and post-graduate clinical training. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [1] INTER-OBSERVER RELIABILITY
    CARO, TM
    ROPER, R
    YOUNG, M
    DANK, GR
    BEHAVIOUR, 1979, 69 : 303 - 315
  • [2] Inter-observer reliability of two pain scales for newborns
    Bellieni, Carlo V.
    Cordelli, Duccio M.
    Caliani, Caterina
    Palazzi, Camilla
    Franci, Nadia
    Perrone, Serafina
    Bagnoli, Franco
    Buonocore, Giuseppe
    EARLY HUMAN DEVELOPMENT, 2007, 83 (08) : 549 - 552
  • [3] The Allen test: A study of inter-observer reliability
    Vu-Rose, Taryn
    Ebramzadeh, Edward
    Lane, Charles S.
    Kuschner, Stuart H.
    Bulletin: Hospital for Joint Diseases, 1997, 56 (02): : 99 - 101
  • [4] Inter-vendor and inter-observer reliability of diffusion tensor imaging in the musculoskeletal system: a multiscanner MR study
    Chianca, Vito
    Albano, Domenico
    Rizzo, Stefania
    Maas, Mario
    Sconfienza, Luca Maria
    Del Grande, Filippo
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [5] Inter-vendor and inter-observer reliability of diffusion tensor imaging in the musculoskeletal system: a multiscanner MR study
    Vito Chianca
    Domenico Albano
    Stefania Rizzo
    Mario Maas
    Luca Maria Sconfienza
    Filippo Del Grande
    Insights into Imaging, 14
  • [6] The inter-observer reliability is very low at clinical examination of parastomal hernia
    Gurmu, Ambatchew
    Matthiessen, Peter
    Nilsson, Sven
    Pahlman, Lars
    Rutegard, Jorgen
    Gunnarsson, Ulf
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2011, 26 (01) : 89 - 95
  • [7] The inter-observer reliability is very low at clinical examination of parastomal hernia
    Ambatchew Gurmu
    Peter Matthiessen
    Sven Nilsson
    Lars Påhlman
    Jörgen Rutegård
    Ulf Gunnarsson
    International Journal of Colorectal Disease, 2011, 26 : 89 - 95
  • [8] A PRACTICE ORAL EXAMINATION RATING-SCALE - INTER-OBSERVER RELIABILITY
    MCCORMICK, WO
    CANADIAN JOURNAL OF PSYCHIATRY-REVUE CANADIENNE DE PSYCHIATRIE, 1981, 26 (04): : 236 - 239
  • [9] Inter-observer reliability of PASI scoring
    Chinniah, N.
    Cabrera, S.
    Descallar, J.
    Cains, G. D.
    AUSTRALASIAN JOURNAL OF DERMATOLOGY, 2014, 55 : 31 - 32
  • [10] International spondyloarthritis inter-observer reliability exercise - The inspire study
    Gladman, D. D.
    Inman, R. D.
    Cook, R. R.
    Maksymowych, W.
    Van der Heijde, D.
    Landewe, R.
    Braun, J.
    Davis, J.
    Mease, P.
    Brandt, J.
    Burgos Vargas, R.
    Chandran, V.
    Helliwell, R.
    Kavanaugh, A.
    O'Shea, F. D.
    Khan, M. A.
    Pipitone, N.
    Rahman, P.
    Reveille, J. D.
    Stone, M.
    Taylor, W.
    Veale, D. J.
    ANNALS OF THE RHEUMATIC DISEASES, 2006, 65 : 217 - 217