Does the placement of an Amplatzer septal occluder device confer benefit in patients with a post-infarction ventricular septal defect?

被引:10
|
作者
Dawson, Alan G. [1 ]
Williams, Stuart G. [2 ]
Cole, Daisy [3 ]
机构
[1] Aberdeen Royal Infirm, Dept Cardiothorac Surg, Aberdeen AB25 2ZN, Scotland
[2] Aberdeen Royal Infirm, Dept Anaesthet, Aberdeen AB25 2ZN, Scotland
[3] Univ Aberdeen, Aberdeen Med Sch, Aberdeen, Scotland
关键词
Myocardial infarction; Ventricular septal defect; Amplatzer; TRANSCATHETER CLOSURE; MYOCARDIAL-INFARCTION;
D O I
10.1093/icvts/ivu293
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was `Is the placement of an Amplatzer septal occluder device across a post-infarction ventricular septal defect a suitable alternative for patients not eligible for surgical repair?' Altogether, 31 papers were found using the reported search, of which 17 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that the insertion of an Amplatzer occluder device in patients with a post-infarction ventricular septal defect (VSD) not amenable to surgical repair can offer benefit in selected patients. Patients with cardiogenic shock frequently have an unfavourable outcome and closure should be considered cautiously. From the literature available, patients have a better outcome if the intervention is delayed by 2 weeks or more possibly due to the maturation of the VSD and recovery of myocardial function. In certain situations, device closure may be complicated by device dislocation or embolization, residual shunting or a tortuous course not amenable to device implantation. In such settings, surgical repair is the only option. In patients who proceed straight to surgical repair with no attempt at percutaneous closure, the overall mortality lies in the region of 43% and similar to percutaneous closure, there is an association observed between those operated within 7 days of the VSD occurrence and those greater than this time. Patients presenting in cardiogenic shock experienced an increased risk of death and if the timing of myocardial infarction to VSD closure could be delayed by 3 weeks, there was a statistically significant reduction in operative mortality. Percutaneous closure of a post-infarction VSD may avoid the requirement for surgical closure. However, in some cases, it provides time to allow the VSD to mature and the patient to stabilize and be optimized acting as a bridge to surgery to offer the best possible outcome for the patient.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 50 条
  • [41] Managing a traumatic ventricular septal defect with atrial septal defect occluder device
    Alidoosti, Mohammad
    Hoseini, Seyed K.
    Shafiee, Akbar
    CARDIOLOGY IN THE YOUNG, 2013, 23 (03) : 436 - 439
  • [42] Delayed Amplatzer Occluder Device Closure of Postinfarction Ventricular Septal Defect: A Case Report
    Ting, Francis
    Bhat, Aditya
    Sammel, Neville
    Muller, David
    CASE REPORTS IN CARDIOLOGY, 2014, 2014
  • [43] Amplatzer Post-Infarction Ventricular Septal Defect Closure via Retrograde Transarterial Access: Easier and Better
    Hildick-Smith, David
    Briceno, Natalia
    Alsanjari, Osama
    Clesham, Gerald J.
    Keeble, Thomas
    Hill, Andrew
    Gomes, Arionilson
    Cockburn, James
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (03): : 263 - 268
  • [44] POST-INFARCTION VENTRICULAR SEPTAL RUPTURE
    不详
    LANCET, 1980, 2 (8192): : 463 - 464
  • [45] Dislocation of Amplatzer Septal Occluder Device after Closure of Secundum Atrial Septal Defect
    Piatkowski, Radoslaw
    Kochanowski, Janusz
    Scislo, Piotr
    Kochman, Janusz
    Opolski, Grzegorz
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) : 1007.e1 - 1007.e2
  • [46] Ventricular septal defect following cardiac trauma:: Percutaneous closure with the Amplatzer Septal Occluder
    Bauriedel, G
    Redel, DA
    Welz, A
    Eckert, HG
    Omran, H
    Lüderitz, B
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2000, 125 (37) : 1081 - 1081
  • [47] POST-INFARCTION VENTRICULAR SEPTAL RUPTURE
    MCKEEVER, L
    SCANLON, P
    JOHNSON, S
    MONTOYA, A
    SULLIVAN, H
    PIFARRE, R
    GUNNAR, R
    CIRCULATION, 1978, 58 (04) : 85 - 85
  • [48] Post-infarction ventricular septal rupture
    David, Tirone E.
    ANNALS OF CARDIOTHORACIC SURGERY, 2022, 11 (03) : 261 - 267
  • [49] Embolized Amplatzer septal occluder device presenting with ventricular fibrillation
    Yuce, Murat
    Ozer, Orhan
    Cakici, Musa
    Cine, Nihat
    Sari, Ibrahim
    Davutoglu, Vedat
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2011, 12 (02) : 131 - 132
  • [50] Use of the amplatzer perimembranous ventricular septal occluder (APMVSO) in a selected group of patients with congenital perimembranous ventricular septal defect
    DeGiovanni, JV
    Shebani, S
    Miller, P
    Tofeig, M
    Clift, P
    Thorne, SA
    Daniels, A
    Hijazi, Z
    HEART, 2004, 90 : A15 - A15