Does the placement of an Amplatzer septal occluder device confer benefit in patients with a post-infarction ventricular septal defect?

被引:10
|
作者
Dawson, Alan G. [1 ]
Williams, Stuart G. [2 ]
Cole, Daisy [3 ]
机构
[1] Aberdeen Royal Infirm, Dept Cardiothorac Surg, Aberdeen AB25 2ZN, Scotland
[2] Aberdeen Royal Infirm, Dept Anaesthet, Aberdeen AB25 2ZN, Scotland
[3] Univ Aberdeen, Aberdeen Med Sch, Aberdeen, Scotland
关键词
Myocardial infarction; Ventricular septal defect; Amplatzer; TRANSCATHETER CLOSURE; MYOCARDIAL-INFARCTION;
D O I
10.1093/icvts/ivu293
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was `Is the placement of an Amplatzer septal occluder device across a post-infarction ventricular septal defect a suitable alternative for patients not eligible for surgical repair?' Altogether, 31 papers were found using the reported search, of which 17 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that the insertion of an Amplatzer occluder device in patients with a post-infarction ventricular septal defect (VSD) not amenable to surgical repair can offer benefit in selected patients. Patients with cardiogenic shock frequently have an unfavourable outcome and closure should be considered cautiously. From the literature available, patients have a better outcome if the intervention is delayed by 2 weeks or more possibly due to the maturation of the VSD and recovery of myocardial function. In certain situations, device closure may be complicated by device dislocation or embolization, residual shunting or a tortuous course not amenable to device implantation. In such settings, surgical repair is the only option. In patients who proceed straight to surgical repair with no attempt at percutaneous closure, the overall mortality lies in the region of 43% and similar to percutaneous closure, there is an association observed between those operated within 7 days of the VSD occurrence and those greater than this time. Patients presenting in cardiogenic shock experienced an increased risk of death and if the timing of myocardial infarction to VSD closure could be delayed by 3 weeks, there was a statistically significant reduction in operative mortality. Percutaneous closure of a post-infarction VSD may avoid the requirement for surgical closure. However, in some cases, it provides time to allow the VSD to mature and the patient to stabilize and be optimized acting as a bridge to surgery to offer the best possible outcome for the patient.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 50 条
  • [1] Transcatheter closure of post-infarction ventricular septal defect with the amplatzer septal occluder device
    Pesonen, E
    Thilen, U
    Sandström, S
    Arheden, H
    Koul, B
    Olsson, SE
    Wilson, RF
    Toher, C
    Bank, A
    Bass, J
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2000, 34 (04) : 446 - 448
  • [2] Percutaneous closure of post-infarction ventricular septal defect using an Amplatzer septal occluder
    Tada N.
    Takizawa K.
    Sakurai M.
    Yaginuma G.
    Inoue N.
    Meguro T.
    Cardiovascular Intervention and Therapeutics, 2013, 28 (2) : 216 - 221
  • [3] Transcatheter closure of post-infarction ventricular septal defects with the Amplatzer septal occluder
    Demkow, M
    Ruzyllo, W
    Chmielak, Z
    Konka, M
    Dzielinska, Z
    Wilczynski, J
    EUROPEAN HEART JOURNAL, 2001, 22 : 63 - 63
  • [4] Transcatheter closure of post-infarction ventricular septal defects with the Amplatzer septal occluder
    Demkow, M
    Ruzyllo, W
    Chmielak, Z
    Kepka, C
    Konka, M
    Dzielinska, Z
    Wilczynski, J
    EUROPEAN HEART JOURNAL, 2003, 24 : 86 - 86
  • [5] Ventricular tachycardia ablation after post-infarction ventricular septal defect occluder placement
    Mikhaylov, Evgeny N.
    Lebedev, Dmitry S.
    Shlyakhto, Evgeny V.
    EUROPACE, 2015, 17 (08): : 1275 - 1275
  • [6] Post-infarction ventricular septal defect treated during the acute phase by transcatheter closure with an amplatzer septal occluder
    Rodés-Cabau, J
    Figueras, J
    Peña, C
    Barrabés, J
    Anívarro, I
    Soler-Soler, J
    REVISTA ESPANOLA DE CARDIOLOGIA, 2003, 56 (06): : 623 - 625
  • [7] Dislodgement of an Amplatzer occluder device causing iatrogenic pulmonary embolism in a patient with post-infarction ventricular septal defect
    Sorgente, Antonio
    Pedrazzini, Giovanni B.
    Faletra, Francesco F.
    Moccetti, Tiziano
    Auricchio, Angelo
    EUROPEAN HEART JOURNAL, 2008, 29 (21) : 2698 - 2698
  • [8] Transcatheter Septal Closure of Post-infarction Ventricular Septal Defect Using the Cocoon Ventricular Septal Occluder
    Bisnar, Regina Elena Mandanas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S58 - S60
  • [9] Transcatheter closure of post-myocardial infarction ventricular septal defect with the amplatzer septal occluder
    Erdem, Abdullah
    Akdeniz, Celal
    Zeybek, Cenap
    Aydemir, Numan Ali
    Celebi, Ahmet
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 21 (01): : 164 - 166
  • [10] Transcatheter closure of post-myocardial infarction ventricular septal defect with Amplatzer septal occluder
    Mullasari, AS
    Umesan, CV
    Krishnan, U
    Srinivasan, S
    Ravikumar, M
    Raghuraman, H
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (04) : 484 - 487