Development of cable fed flash X-ray (FXR) system

被引:6
|
作者
Menon, Rakhee [1 ,2 ]
Mitra, S. [1 ,2 ]
Patel, A. S. [1 ]
Kumar, R. [2 ,3 ]
Singh, G. [2 ,3 ]
Senthil, K. [1 ]
Kumar, Ranjeet [1 ]
Kolge, T. S. [1 ]
Roy, Amitava [1 ]
Acharya, S. [1 ]
Biswas, D. [2 ,3 ]
Sharma, Archana [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Accelerator & Pulse Power Div, Bombay 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Bombay 400085, Maharashtra, India
[3] Bhabha Atom Res Ctr, Math Phys & Reactor Theory Sect, Bombay 400085, Maharashtra, India
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2017年 / 88卷 / 08期
关键词
X ray apparatus - Monte Carlo methods - Electron sources - Intelligent systems - X ray radiography - Electron beams;
D O I
10.1063/1.4998994
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Flash X-ray sources driven by pulsed power find applications in industrial radiography, and a portable X-ray source is ideal where the radiography needs to be taken at the test site. A compact and portable flash X-ray (FXR) system based on a Marx generator has been developed with the high voltage fed to the FXR tube via a cable feed-through arrangement. Hard bremsstrahlung X-rays of few tens of nanosecond duration are generated by impinging intense electron beams on an anode target of high Z material. An industrial X-ray source is developed with source size as low as 1 mm. The system can be operated from 150 kV to 450 kV peak voltages and a dose of 10 mR has been measured at 1m distance from the source window. The modeling of the FXR source has been carried out using particle-in-cell and Monte Carlo simulations for the electron beam dynamics and X-ray generation, respectively. The angular dose profile of X-ray has been measured and compared with the simulation.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Portable flash x-ray inspector
    Zhang, Q
    Li, TX
    Wang, D
    Guo, JD
    Lu, QN
    22ND INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 1997, 2869 : 759 - 763
  • [32] FLASH X-RAY IN SPACE PROGRAM
    LEWIS, RH
    INDUSTRIAL PHOTOGRAPHY, 1968, 17 (08): : 23 - &
  • [33] PRODUCTION OF X-RAY FLASH INTERFERENCES
    KREHL, P
    MESSTECHNIK, 1972, 80 (09): : 252 - +
  • [34] STABILIZED FLASH X-RAY DISCHARGES
    HANDEL, SK
    BERGFELD.J
    ARKIV FOR FYSIK, 1965, 30 (01): : 33 - +
  • [35] STABILIZATION OF A FLASH X-RAY DISCHARGE
    HANDEL, SK
    BERGFELDT, J
    ARKIV FOR FYSIK, 1965, 30 (06): : 554 - +
  • [36] Experimental study and development of a single focus burst X-ray flash
    Drissi, MM
    Dudemaine, M
    Viladrosa, R
    Robert, E
    Cachoncinlle, C
    Pouvesle, JM
    PPC-2003: 14TH IEEE INTERNATIONAL PULSED POWER CONFERENCE, VOLS 1 AND 2, DIGEST OF TECHNICAL PAPERS, 2003, : 752 - 755
  • [37] Experimental study and development of a single focus burst X-ray flash
    Idrissi, MM
    Viladrosa, R
    Robert, E
    Cachoncinlle, C
    Pouvesle, JM
    25TH INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 2003, 4948 : 598 - 603
  • [38] Development of X-ray scanning system Sowa
    Bogowicz, Jozef
    Chabera, Mariusz
    Dziewiecki, Wojciech
    Kaimierczak, Kacper
    Klimaszewski, Jan
    Kosinski, Tymoteusz
    Lubian, Andrzej
    Matusiak, Michal
    Wasilewski, Adam
    Wojciechowski, Marcin
    Wronka, Slawomir
    Zakrzewski, Tomasz
    NUKLEONIKA, 2020, 65 (04) : 229 - 232
  • [39] Flash X-ray Diffraction Imaging System and Study on Experiment Approach
    Tang B.
    Hei D.-W.
    Ma G.
    Sheng L.
    Wei F.-L.
    Xia J.-T.
    Luo J.-H.
    Zhou H.-S.
    Guangzi Xuebao/Acta Photonica Sinica, 2017, 46 (12):
  • [40] A table-top flash contact x-ray microscope system
    Shimizu, H
    Majima, T
    Tomie, T
    Stead, AD
    Ford, T
    Miura, K
    Yamada, M
    Kanayama, T
    BIOPHYSICAL JOURNAL, 1996, 70 (02) : TU479 - TU479