Development of cable fed flash X-ray (FXR) system

被引:6
|
作者
Menon, Rakhee [1 ,2 ]
Mitra, S. [1 ,2 ]
Patel, A. S. [1 ]
Kumar, R. [2 ,3 ]
Singh, G. [2 ,3 ]
Senthil, K. [1 ]
Kumar, Ranjeet [1 ]
Kolge, T. S. [1 ]
Roy, Amitava [1 ]
Acharya, S. [1 ]
Biswas, D. [2 ,3 ]
Sharma, Archana [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Accelerator & Pulse Power Div, Bombay 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Bombay 400085, Maharashtra, India
[3] Bhabha Atom Res Ctr, Math Phys & Reactor Theory Sect, Bombay 400085, Maharashtra, India
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2017年 / 88卷 / 08期
关键词
X ray apparatus - Monte Carlo methods - Electron sources - Intelligent systems - X ray radiography - Electron beams;
D O I
10.1063/1.4998994
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Flash X-ray sources driven by pulsed power find applications in industrial radiography, and a portable X-ray source is ideal where the radiography needs to be taken at the test site. A compact and portable flash X-ray (FXR) system based on a Marx generator has been developed with the high voltage fed to the FXR tube via a cable feed-through arrangement. Hard bremsstrahlung X-rays of few tens of nanosecond duration are generated by impinging intense electron beams on an anode target of high Z material. An industrial X-ray source is developed with source size as low as 1 mm. The system can be operated from 150 kV to 450 kV peak voltages and a dose of 10 mR has been measured at 1m distance from the source window. The modeling of the FXR source has been carried out using particle-in-cell and Monte Carlo simulations for the electron beam dynamics and X-ray generation, respectively. The angular dose profile of X-ray has been measured and compared with the simulation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The LLNL flash X-ray induction linear accelerator (FXR)
    Multhauf, LG
    Back, NL
    Simmons, LF
    Zentler, JM
    Scarpetti, RD
    25TH INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 2003, 4948 : 622 - 633
  • [2] Upgrades to the LLNL flash x-ray induction linear accelerator (FXR)
    Scarpetti, RD
    Boyd, JK
    Earley, GG
    Griffin, KL
    Kerr, RG
    Kihara, R
    Ong, MM
    Zentler, JM
    Back, NL
    11TH IEEE INTERNATIONAL PULSED POWER CONFERENCE - DIGEST OF TECHNICAL PAPERS, VOLS. 1 & 2, 1997, : 597 - 602
  • [3] A 500 kV, 10 kA, 40 ns coaxial Marx generator pulser for cable fed flash x-ray system
    Patel, A. S.
    Senthil, K.
    Menon, Rakhee
    Basak, Ankan
    Chandra, Romesh
    Mitra, S.
    Roy, Amitava
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (10):
  • [4] Real-life pulse flattening on the LLNL flash X-Ray (FXR) machine
    DeHope, W. J.
    Jacob, J. S.
    Kreitzer, B. R.
    Kihara, R.
    Ong, M. M.
    Zentler, J. M.
    2007 IEEE PULSED POWER CONFERENCE, VOLS 1-4, 2007, : 1261 - 1263
  • [5] Development of online cable eccentricity detection system based on X-ray CCD
    Chen, Jian-Zhen
    Li, Bin
    Wei, Kai-Xia
    Guo, Lan-Ying
    Qu, Guo-Pu
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (02): : 230 - 233
  • [6] Design of a high field stress, velvet cathode for the Flash X-ray (FXR) induction accelerator
    Houck, T.
    Brown, C.
    Fleming, D.
    Kreitzer, B.
    Lewis, K.
    Ong, M.
    Zender, J.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 2267 - 2269
  • [7] LLNL flash x-ray radiography machine (FXR) double-pulse upgrade diagnostics
    Ong, M
    Avalle, C
    Richardson, R
    Zentler, J
    11TH IEEE INTERNATIONAL PULSED POWER CONFERENCE - DIGEST OF TECHNICAL PAPERS, VOLS. 1 & 2, 1997, : 430 - 435
  • [8] Estimating the reliability of Lawrence Livermore National Laboratory (LLNL) flash X-ray (FXR) machine
    Ong, Mike M.
    Kihara, Ron
    Zentler, Jan M.
    Kreitzer, Blake R.
    DeHope, William J.
    2007 IEEE PULSED POWER CONFERENCE, VOLS 1-4, 2007, : 1078 - 1081
  • [9] Development and evaluation of a four-channel digital flash X-ray imaging system
    Wang, Y
    Cheng, JP
    Li, YJ
    Tian, H
    Du, HL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 496 (2-3): : 496 - 503
  • [10] FLASH X-RAY MACHINES
    PASCHAL, FL
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (01): : 109 - &