Benchmarking a novel inorganic scintillation detector for applications in radiation therapy

被引:22
|
作者
Alharbi, Majed [1 ]
Martyn, Michael [2 ]
O'Keeffe, Sinead [3 ]
Therriault-Proulx, Francois [4 ,5 ]
Beaulieu, Luc [4 ,5 ,6 ,7 ]
Foley, Mark [1 ]
机构
[1] Natl Univ Ireland Galway, Sch Phys, Galway, Ireland
[2] Galway Univ Hosp, Dept Med Phys & Clin Engn, Galway, Ireland
[3] Univ Limerick, Opt Fibre Sensors Res Ctr, Limerick, Ireland
[4] CHU Quebec, Dept Radiooncol, Quebec City, PQ G1R 3S1, Canada
[5] CHU Quebec, Ctr Rech, Quebec City, PQ G1R 3S1, Canada
[6] Univ Laval, Dept Phys, Quebec City, PQ G1V 0A6, Canada
[7] Univ Laval, Ctr Rech Canc, Quebec City, PQ G1V 0A6, Canada
关键词
Inorganic scintillating detector; Hyperspectral technique; Cerenkov radiation; Band-pass filters; Monte Carlo simulations; ENERGY BEAM DOSIMETRY; OPTICAL-FIBER SENSOR; MONTE-CARLO; CERENKOV RADIATION; ELECTRON; PHOTON; VALIDATION; SYSTEM; FIELD;
D O I
10.1016/j.ejmp.2019.11.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to investigate the contribution of Cerenkov radiation to the overall signal measured with a novel inorganic scintillating detector (ISD). Methods: An ISD based on terbium doped gadolinium oxysulphide (Gd2O2S:Tb) was used. A hyperspectral technique separated the Cerenkov signal from the radioluminescence (RL) signal of the ISD. The relative contribution of Cerenkov radiation was evaluated under different conditions. The efficiency of using simple spectral correction to reduce the Cerenkov contribution was quantified. Other experiments investigated were the doseper-pulse dependence observed in our previous study and the absorbed-dose energy dependence when acquiring percentage depth dose curves using Monte Carlo (MC) simulations. Results: The maximum relative contribution of Cerenkov radiation was 2.10% for a 10 x 10 cm(2) field at 10 cm depth. However, this percentage increased to 24% when the ISD was 7 cm out of field and exposed to a 10 x 10 cm2 field. Using 15 nm and 5 nm band-pass filters reduced the Cerenkov contribution across all experimental conditions by a maximum of 75% and 82%, respectively. The MC simulation results show discrepancies between the measured and simulated PDD profiles using the Gd2O2S:Tb scintillator at depth. Conclusion: This study showed that while Gd2O2S:Tb ISD provides high-signal intensity, the contribution of Cerenkov radiation under specific conditions can be significant. However, narrow band-pass filters can reduce the Cerenkov signal to a negligible level. The MC simulations suggest mechanisms other than the stem effect and the absorbed-dose energy dependence influence the response of the Gd2O2S:Tb scintillator measurements at depth.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [31] Evaluation of a New Plastic Scintillation Detector for Stereotactic Radiosurgery Applications
    Jacqmin, D.
    Miller, J.
    Labby, Z.
    Shepard, A.
    Barraclough, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E648 - E648
  • [32] A transition radiation detector based on thin inorganic scintillators
    Berdnikov, V. V.
    Gurov, Yu B.
    Dolgoshein, B. A.
    Dmitrenko, V. V.
    Zadneprovskii, B. I.
    Kantserov, V. A.
    Sosnovtsev, V. V.
    Tikhomirov, V. O.
    Shmeleva, A. P.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2013, 56 (02) : 146 - 150
  • [33] A transition radiation detector based on thin inorganic scintillators
    V. V. Berdnikov
    Yu. B. Gurov
    B. A. Dolgoshein
    V. V. Dmitrenko
    B. I. Zadneprovskii
    V. A. Kantserov
    V. V. Sosnovtsev
    V. O. Tikhomirov
    A. P. Shmeleva
    Instruments and Experimental Techniques, 2013, 56 : 146 - 150
  • [34] Application of a ZnO UV sensor for a scintillation-type radiation detector
    Abe, T.
    Suzuki, Y.
    Nakagawa, A.
    Chiba, T.
    Nakagawa, M.
    Kashiwaba, Y.
    Niikura, I.
    Kashiwaba, Y.
    Osada, H.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2019, 30 (18) : 16873 - 16877
  • [35] Development of a fast radiation detector based on barium fluoride scintillation crystal
    Han, Hetong
    Zhang, Zichuan
    Weng, Xiufeng
    Liu, Junhong
    Guan, Xingyin
    Zhang, Kan
    Li, Gang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (07):
  • [36] Application of a ZnO UV sensor for a scintillation-type radiation detector
    T. Abe
    Y. Suzuki
    A. Nakagawa
    T. Chiba
    M. Nakagawa
    Y. Kashiwaba
    I. Niikura
    Y. Kashiwaba
    H. Osada
    Journal of Materials Science: Materials in Electronics, 2019, 30 : 16873 - 16877
  • [37] Radiation hardness tests of a scintillation detector with wavelength shifting fiber readout
    Alfaro, R.
    Cruz, E.
    Martinez, M. I.
    Montano, L. M.
    Paic, G.
    Sandoval, A.
    PARTICLES AND FIELDS, PT A, 2006, 857 : 218 - +
  • [38] One-Pixel Prototype of a Novel Polycrystalline CdTe-Based Multi layer Detector for Radiation Therapy Imaging Applications
    Shvydka, D.
    Karpov, V.
    Warrell, G.
    Parsai, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3743 - 3743
  • [39] Search for neutrino radiation from collapsing stars with the Artyomovsk scintillation detector
    Ashikhmin V.V.
    Enikeev R.I.
    Pokropivny A.V.
    Ryazhskaya O.G.
    Ryasny V.G.
    Bulletin of the Russian Academy of Sciences: Physics, 2013, 77 (11) : 1333 - 1335
  • [40] Preliminary Evaluation of the Impact of Cerenkov Radiation in a Stemless Plastic Scintillation Detector
    Hupman, Michael
    Hill, Ian
    Syme, Alasdair
    Monajemi, Thalat
    MEDICAL PHYSICS, 2019, 46 (11) : 5390 - 5391