Benchmarking a novel inorganic scintillation detector for applications in radiation therapy

被引:22
|
作者
Alharbi, Majed [1 ]
Martyn, Michael [2 ]
O'Keeffe, Sinead [3 ]
Therriault-Proulx, Francois [4 ,5 ]
Beaulieu, Luc [4 ,5 ,6 ,7 ]
Foley, Mark [1 ]
机构
[1] Natl Univ Ireland Galway, Sch Phys, Galway, Ireland
[2] Galway Univ Hosp, Dept Med Phys & Clin Engn, Galway, Ireland
[3] Univ Limerick, Opt Fibre Sensors Res Ctr, Limerick, Ireland
[4] CHU Quebec, Dept Radiooncol, Quebec City, PQ G1R 3S1, Canada
[5] CHU Quebec, Ctr Rech, Quebec City, PQ G1R 3S1, Canada
[6] Univ Laval, Dept Phys, Quebec City, PQ G1V 0A6, Canada
[7] Univ Laval, Ctr Rech Canc, Quebec City, PQ G1V 0A6, Canada
关键词
Inorganic scintillating detector; Hyperspectral technique; Cerenkov radiation; Band-pass filters; Monte Carlo simulations; ENERGY BEAM DOSIMETRY; OPTICAL-FIBER SENSOR; MONTE-CARLO; CERENKOV RADIATION; ELECTRON; PHOTON; VALIDATION; SYSTEM; FIELD;
D O I
10.1016/j.ejmp.2019.11.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to investigate the contribution of Cerenkov radiation to the overall signal measured with a novel inorganic scintillating detector (ISD). Methods: An ISD based on terbium doped gadolinium oxysulphide (Gd2O2S:Tb) was used. A hyperspectral technique separated the Cerenkov signal from the radioluminescence (RL) signal of the ISD. The relative contribution of Cerenkov radiation was evaluated under different conditions. The efficiency of using simple spectral correction to reduce the Cerenkov contribution was quantified. Other experiments investigated were the doseper-pulse dependence observed in our previous study and the absorbed-dose energy dependence when acquiring percentage depth dose curves using Monte Carlo (MC) simulations. Results: The maximum relative contribution of Cerenkov radiation was 2.10% for a 10 x 10 cm(2) field at 10 cm depth. However, this percentage increased to 24% when the ISD was 7 cm out of field and exposed to a 10 x 10 cm2 field. Using 15 nm and 5 nm band-pass filters reduced the Cerenkov contribution across all experimental conditions by a maximum of 75% and 82%, respectively. The MC simulation results show discrepancies between the measured and simulated PDD profiles using the Gd2O2S:Tb scintillator at depth. Conclusion: This study showed that while Gd2O2S:Tb ISD provides high-signal intensity, the contribution of Cerenkov radiation under specific conditions can be significant. However, narrow band-pass filters can reduce the Cerenkov signal to a negligible level. The MC simulations suggest mechanisms other than the stem effect and the absorbed-dose energy dependence influence the response of the Gd2O2S:Tb scintillator measurements at depth.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [1] Optimizing Novel Inorganic Scintillation Detectors for Applications in Medical Physics
    Byrne, Kevin
    Contan, Skye
    Bazalova-Carter, Magdalena
    Foley, Mark
    2020 IEEE SENSORS, 2020,
  • [2] Inorganic scintillation crystals and their applications
    Li, Peijun
    Wuji Cailiao Xuebao/Journal of Inorganic Materials, 1993, 8 (04): : 385 - 398
  • [3] BEST IN PHYSICS (THERAPY) - A Novel Multi-Point Plastic Scintillation Detector for in Vivo Dosimetry and Quality Assurance in Radiation Therapy
    Therriault-Proulx, F.
    Beaulieu, L.
    Archambault, L.
    Beddar, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3967 - 3967
  • [4] COINCIDENCE CIRCUIT FOR A SCINTILLATION DETECTOR OF RADIATION
    ELMORE, WC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1950, 21 (07): : 649 - 652
  • [5] Novel Multilayer Detector Design Using Polycrystalline CdTe for Radiation Therapy Imaging Applications
    Shvydka, D.
    Karpov, V.
    Paudel, N.
    Parsai, E.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [6] Novel detector for portal imaging in radiation therapy
    Ostling, J
    Wallmark, M
    Brahme, A
    Danielsson, M
    Iacobaeus, C
    Fonte, P
    Peskov, V
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 84 - 95
  • [7] NEW RADIATION DETECTOR OF PLASTIC SCINTILLATION FIBER
    IMAI, SI
    SORAMOTO, S
    MOCHIKI, KI
    IGUCHI, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (04): : 1093 - 1097
  • [8] Dosimetric Evaluation of Plastic Scintillation Detector for Skin Collimation in Electron Beam Radiation Therapy
    Yang, K.
    Sharma, S.
    Ju, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E830 - E830
  • [9] Radiation detector developments in medical applications: Inorganic scintillators in positron emission tomography
    van Eijk, Carel W. E.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 13 - 21
  • [10] Development of an inorganic scintillation detector system for in vivo dosimetry for brachytherapy
    Kertzscher, G.
    Beddar, S.