A compact, low-cost, quantitative and multiplexed fluorescence detection platform for point-of-care applications

被引:34
|
作者
Obahiagbon, Uwadiae [1 ]
Smith, Joseph T. [1 ,2 ]
Zhu, Meilin [2 ]
Katchman, Benjamin A. [2 ]
Arafa, Hany [1 ]
Anderson, Karen S. [2 ]
Christen, Jennifer M. Blain [1 ]
机构
[1] Arizona State Univ, Sch Elect Comp & Energy Engn, Goldwater Ctr, Suite 334, Tempe, AZ 85287 USA
[2] Arizona State Univ, Ctr Personalized Diagnost, Biodesign Inst, Tempe, AZ 85281 USA
来源
基金
美国国家科学基金会;
关键词
Point-of-care; Diagnostics; Multiplexed; Fluorescence; Colorimetry; Limit of detection; INTEGRATION; SENSITIVITY; SENSORS;
D O I
10.1016/j.bios.2018.04.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An effective method of combating infectious diseases is the deployment of hand-held devices at the point-of-care (POC) for screening or self-monitoring applications. There is a need for very sensitive, low-cost and quantitative diagnostic devices. In this study, we present a low-cost, multiplexed fluorescence detection platform that has a high sensitivity and wide dynamic range. Our system features inexpensive 3 x 3 mm interference filters with a high stopband rejection, sharp transition edges, and greater than 90% transmission in the passband. In addition to the filters, we improve signal-to-noise ratio by leveraging time for accuracy using a charge-integration-based readout. The fluorescence sensing platform provides a sensitivity to photon flux of similar to 1 x 10(4) photons/mm(2) sec and has the potential for 2-3 orders of magnitude improvement in sensitivity over standard colorimetric detection that uses colored latex microspheres. We also detail the design, development, and characterization of our low-cost fluorescence detection platform and demonstrate 100% and 97.96% reduction in crosstalk probability and filter cost, respectively. This is achieved by reducing filter dimensions and ensuring appropriate channel isolation in a 2 x 2 array configuration. Practical considerations with low-cost interference filter system design, analysis, and system performance are also discussed. The performance of our platform is compared to that of a standard laboratory array scanner. We also demonstrate the detection of antibodies to human papillomavirus (HPV16) E7 protein, as a potential biomarker for early cervical cancer detection in human plasma.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [41] Low-cost compact CWDM filter platform
    Li, Y
    Luo, C
    Wang, DY
    Li, LZ
    Li, J
    Wu, F
    Tsay, WS
    APOC 2003: ASIA-PACIFIC OPTICAL AND WIRELESS COMMUNICATIONS; OPTICAL FIBERS AND PASSIVE COMPONENTS, 2003, 5279 : 140 - 145
  • [42] A low-cost smartphone-based platform for highly sensitive point-of-care testing with persistent luminescent phosphors
    Paterson, Andrew S.
    Raja, Balakrishnan
    Mandadi, Vinay
    Townsend, Blane
    Lee, Miles
    Buell, Alex
    Binh Vu
    Brgoch, Jakoah
    Willson, Richard C.
    LAB ON A CHIP, 2017, 17 (06) : 1051 - 1059
  • [43] A microfluidic platform with digital readout and ultra-low detection limit for quantitative point-of-care diagnostics
    Li, Ying
    Xuan, Jie
    Song, Yujun
    Wang, Ping
    Qin, Lidong
    LAB ON A CHIP, 2015, 15 (16) : 3300 - 3306
  • [44] A portable and low-cost centrifugal microfluidic platform for multiplexed colorimetric detection of protein biomarkers
    Akhtar, Ahmad S.
    Soares, Ruben R. G.
    Pinto, Ines F.
    Russom, Aman
    ANALYTICA CHIMICA ACTA, 2023, 1245
  • [45] Customized low-cost high-throughput amplifier for electro-fluidic detection of cell volume changes in point-of-care applications
    Kaushik, Saurabh
    Selvanathan, Prabhakaran
    Soni, Gautam Vivek
    PLOS ONE, 2022, 17 (04):
  • [46] Rapid Low-Cost Microfluidic Detection in Point of Care Diagnostics
    Srikrishnan Pillai Raju
    Xiaogang Chu
    Journal of Medical Systems, 2018, 42
  • [47] Rapid Low-Cost Microfluidic Detection in Point of Care Diagnostics
    Raju, Srikrishnan Pillai
    Chu, Xiaogang
    JOURNAL OF MEDICAL SYSTEMS, 2018, 42 (10)
  • [48] A Novel Low-Cost Simulation Model for Point-of-Care Ultrasound Intussusception Practice
    Williams, Jasmine
    Doctor, Jessica
    Jeffers, Kristine
    Myers, Melissa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [49] A Low-Cost Smartphone-Based Electrochemical Biosensor for Point-of-Care Diagnostics
    Sun, Alexander
    Wambach, Travis
    Venkatesh, A. G.
    Hall, Drew A.
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 312 - 315
  • [50] Design and Adoption of Low-Cost Point-of-Care Diagnostic Devices: Syrian Case
    Alseed, M. Munzer
    Syed, Hamzah
    Onbasli, Mehmet Cengiz
    Yetisen, Ali K.
    Tasoglu, Savas
    MICROMACHINES, 2021, 12 (08)