Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems

被引:2
|
作者
Lehmann, Karl Martin [1 ]
Weyhrauch, Michael [1 ]
Bjelopavlovic, Monika [1 ]
Scheller, Herbert [1 ]
Staedt, Henning [2 ]
Ottl, Peter [2 ,3 ]
Kaemmerer, Peer W. [4 ]
Wentaschek, Stefan [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Prosthodont & Mat Sci, Univ Med Ctr, Augustuspl 2, D-55131 Mainz, Germany
[2] Univ Rostock, Dept Prosthodont & Mat Sci, Strempelstr 13, D-18057 Rostock, Germany
[3] Univ Rostock, Dept Life Light & Matter, Albert Einstein Str 25, D-18059 Rostock, Germany
[4] Johannes Gutenberg Univ Mainz, Dept Oral & Maxillofacial Surg, Univ Med Ctr, Augustuspl 2, D-55131 Mainz, Germany
关键词
marginal fit; internal fit; zirconia; FPD; CAD; CAM; CLINICAL FIT; ADAPTATION; CROWNS; COPINGS;
D O I
10.3390/ma14102663
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Background: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. Purpose: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. Materials and Methods: Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A-D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferroni adjustment was performed. The global level of significance was set at 5%. Results: The mean gap size ranged from 84 to 132 mu m (SD 43-71 mu m). The CAD/CAM systems showed significant variance (p < 0.001), and system A (VHF) showed the smallest gaps. The smallest gaps for each system were in the molar part and in the marginal region of the frameworks (p < 0.001). Conclusions: The CAD/CAM systems showed significantly different gap sizes, particularly between premolars and molars and among the marginal, axial and occlusal regions. All of the systems are suitable for clinical application.
引用
收藏
页数:8
相关论文
共 34 条
  • [1] Failing Four-Unit Maxillary Fixed Partial Denture: Part 1
    Vailati, Francesca
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2006, 1 (01): : 78 - 86
  • [2] Failing Four-Unit Maxillary Fixed Partial Denture: Part 2
    Vailati, Francesca
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2006, 1 (02): : 158 - 164
  • [3] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Almeida e Silva, Junio S.
    Erdelt, Kurt
    Edelhoff, Daniel
    Araujo, Elito
    Stimmelmayr, Michael
    Cardoso Vieira, Luiz Clovis
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) : 515 - 523
  • [4] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Júnio S. Almeida e Silva
    Kurt Erdelt
    Daniel Edelhoff
    Élito Araújo
    Michael Stimmelmayr
    Luiz Clovis Cardoso Vieira
    Jan-Frederik Güth
    Clinical Oral Investigations, 2014, 18 : 515 - 523
  • [5] Finite element analysis of a four-unit all-ceramic fixed partial denture
    Dittmer, Marc Philipp
    Kohorst, Philipp
    Borchers, Lothar
    Stiesch-Scholz, Meike
    ACTA BIOMATERIALIA, 2009, 5 (04) : 1349 - 1355
  • [6] Effect of Configurations of Implants Supporting a Four-Unit Fixed Partial Denture on Loading Distribution
    Yoda, Nobuhiro
    Sun, Jian
    Matsudate, Yoshiki
    Hong, Guang
    Kawata, Tetsuo
    Sasaki, Keiichi
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (01) : 68 - 70
  • [7] Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks
    Kohorst, Philipp
    Herzog, Timo J.
    Borchers, Lothar
    Stiesch-Scholz, Meike
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2007, 115 (02) : 161 - 166
  • [8] Clinical fit of four-unit zirconia posterior fixed dental prostheses
    Reich, Sven
    Kappe, Karsten
    Teschner, Hubertus
    Schmitt, Johannes
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2008, 116 (06) : 579 - 584
  • [9] Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems
    Kohorst, Philipp
    Brinkmann, Henrike
    Li, Jiang
    Borchers, Lothar
    Stiesch, Meike
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (03) : 319 - 325
  • [10] Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks
    Komine, F
    Gerds, T
    Witkowski, S
    Strub, JR
    ACTA ODONTOLOGICA SCANDINAVICA, 2005, 63 (06) : 361 - 366